SearcharxivSearch

arXiv subjects

C. Filliard

Publications and source records attributed to C. Filliard.

4 recordsLinked to original sources

Planck 2013 results. VIII. HFI photometric calibration and mapmaking

This paper describes the processing applied to the HFI cleaned time-ordered data to produce photometrically calibrated maps. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To get the best accuracy on the calibration on such a large range, two different photometric calibration schemes have to be used. The 545 and 857 \GHz\ data are calibrated using Uranus and Neptune flux density measurements, compared with models of their atmospheric emissions to calibrate the data. The lower frequencies (below 353 GHz) are calibrated using the cosmological microwave background dipole.One of the components of this anisotropy results from the orbital motion of the satellite in the Solar System, and is therefore time-variable. Photometric calibration is thus tightly linked to mapmaking, which also addresses low frequency noise removal. The 2013 released HFI data show some evidence for apparent gain variations of the HFI bolometers' detection chain. These variations were identified by comparing observations taken more than one year apart in the same configuration. We developed an effective correction to limit its effect on calibration, and assess its accuracy. We present several methods used to estimate the precision of the photometric calibration. We distinguish relative (from one detector to another, or from one frequency to another) and absolute uncertainties. In both cases, we found that these uncertainties range from a few $10^{-3}$ to several per cents from 100 to 857 GHz. We describe the pipeline producing the maps from the HFI timelines, based on the photometric calibration parameters and we detail the scheme used to a posteriori set the zero level of the maps. We also briefly discuss the cross-calibration between HFI and the SPIRE instrument on board Herschel. We finally summarize the basic characteristics of the set of the HFI maps from the 2013 Planck data release.

astro-ph.CO

Iterative destriping and photometric calibration for Planck-HFI, polarized, multi-detector map-making

We present an iterative scheme designed to recover calibrated I, Q, and U maps from Planck-HFI data using the orbital dipole due to the satellite motion with respect to the Solar System frame. It combines a map reconstruction, based on a destriping technique, juxtaposed with an absolute calibration algorithm. We evaluate systematic and statistical uncertainties incurred during both these steps with the help of realistic, Planck-like simulations containing CMB, foreground components and instrumental noise, and assess the accuracy of the sky map reconstruction by considering the maps of the residuals and their spectra. In particular, we discuss destriping residuals for polarization sensitive detectors similar to those of Planck-HFI under different noise hypotheses and show that these residuals are negligible (for intensity maps) or smaller than the white noise level (for Q and U Stokes maps), for l > 50. We also demonstrate that the combined level of residuals of this scheme remains comparable to those of the destriping-only case except at very low l where residuals from the calibration appear. For all the considered noise hypotheses, the relative calibration precision is on the order of a few 10e-4, with a systematic bias of the same order of magnitude.

astro-ph.CO

Planck early results. VI. The High Frequency Instrument data processing

We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz with an angular resolution ranging from 9.9 to 4.4^2. The white noise level is around 1.5 {\mu}K degree or less in the 3 main CMB channels (100--217GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy. They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears to be of high quality and we expect that with further refinements of the data processing we should be able to achieve, or exceed, the science goals of the Planck project.

astro-ph.CO

Planck early results: first assessment of the High Frequency Instrument in-flight performance

The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during ground testing. Observations of Mars, Jupiter, and Saturn verified both the optical system and the time response of the detection chains. The optical beams are close to predictions from physical optics modeling. The time response of the detection chains is close to pre-launch measurements. The detectors suffer from an unexpected high flux of cosmic rays related to low solar activity. Due to the redundancy of Planck's observations strategy, the removal of a few percent of data contaminated by glitches does not affect significantly the sensitivity. The cosmic rays heat up significantly the bolometer plate and the modulation on periods of days to months of the heat load creates a common drift of all bolometer signals which do not affect the scientific capabilities. Only the high energy cosmic rays showers induce inhomogeneous heating which is a probable source of low frequency noise.

astro-ph.IM