High-precision measurement of the kaonic hydrogen 1s level shift and width with SIDDHARTA-2

Kaonic atoms provide a unique experimental probe of strong interaction in the low-energy regime. In particular, the strong-interaction-induced shift ($\varepsilon_{1\text{s}}$) and width ($\Gamma_{1\text{s}}$) of kaonic hydrogen directly constrain the low-energy antikaon-nucleon ($\bar{K}N$) interaction at threshold and the theoretical description of the $\Lambda$(1405) resonance. We report a new high-precision measurement of kaonic hydrogen X-ray transitions performed by the SIDDHARTA-2 experiment at the DA$\Phi$NE collider (INFN-LNF), based on an integrated luminosity of 237 pb$^{-1}$. The extracted values, $\varepsilon_{1\text{s}}\,=\,-303.0\,\pm\,17.0\,(stat.)\,\pm\,2.5\,(syst.)$ eV and $\Gamma_{1\text{s}}\,=\,607\,\pm\,62\,(stat.)\,\pm\,6\,(syst.)$ eV, represent the most precise determination to date, improving the precision by approximately a factor-of-two with respect to the previous SIDDHARTA measurement. These results significantly tighten the experimental constraints on theoretical description of the low-energy $\bar{K}N$ interaction.

nucl-ex

Energy Calibration and Performance of HPGe Detectors in the LEGEND-200 Experiment

This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal processing pipeline, the methodologies for peak-shape modeling and energy calibration procedures utilizing weekly $^{228}$Th source calibration runs. The optimized energy reconstruction achieves a combined average resolution of $(2.47 \pm 0.08)$~keV at $Q_{\beta\beta} = 2039$~keV. The weekly variation of calibration peak positions are below 0.05~keV for energies up to 2614.5~keV, showing a high stability of the energy scale over time and across detectors. Furthermore, systematic corrections effectively address residual non-linearities and energy bias in the region of interest.

physics.ins-det

Bound-state QED test above the Schwinger limit with kaonic fluorine

Kaonic atoms, formed when a negatively charged kaon replaces an electron in an atomic orbit, provide access to bound-state quantum electrodynamics (BSQED) in electromagnetic fields far stronger than in ordinary atoms. Here, we report an experimental test of BSQED in a regime where the mean Coulomb field exceeds the Schwinger limit. Using high-precision x-ray spectroscopy of kaonic fluorine with the SIDDHARTA-2 experiment at DA$\Phi$NE, corresponding to an integrated luminosity of 22.4 pb$^{-1}$, we observe transitions involving the 4f and 3d levels, probing field-to-Schwinger-limit ratios of 1.11 and 3.70, respectively. The measured transition energies agree with state-of-the-art Dirac-Fock calculations. In particular, the 5g-4f transition showing a residual of 5.8 $\pm$ 4.7 (stat.) $\pm$ 5.5 (syst.) eV and a $\sim$ 9$\sigma$ sensitivity to QED contributions. These results provide a direct test of BSQED in the strong-field regime of QED above the Schwinger limit, opening a new avenue for precision studies in extreme electromagnetic fields.

physics.atom-ph

KATRIN Sensitivity to keV Sterile Neutrinos with the TRISTAN Detector Upgrade

Sterile neutrinos in the keV mass range are a well-motivated extension of the Standard Model and viable dark matter candidates. Their existence can be probed in laboratory experiments, as the admixture of a sterile state would induce a characteristic kink-like distortion in the $\beta$-decay electron energy spectrum. The KATRIN experiment is designed to measure the effective electron neutrino mass with sub-eV sensitivity by analyzing the endpoint region of the tritium $\beta$-decay spectrum. Following the completion of its neutrino mass program, KATRIN will extend its physics reach to the search for keV-scale sterile neutrinos. This effort will be enabled by the TRISTAN detector, a newly developed silicon drift detector array optimized for differential measurements at high rates and energies well below the endpoint. In this article, we present the projected sensitivity of KATRIN to keV-scale sterile neutrinos using a dedicated simulation framework. With four months of detector livetime, KATRIN has the statistical power to probe mixing amplitudes at the level of $|U_{e4}|^2 \sim 10^{-6}$ for sterile neutrino masses in the (4$-$13) keV range, significantly extending the reach of previous laboratory searches. The major experimental systematic uncertainties investigated in this work reduces the sensitivity by a factor of 10$-$50 over the same mass range.

hep-ex

New 1mm thick Silicon Drift Detectors for future researches of Kaonic Atoms and the Pauli Exclusion principle

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a sensitive probe of the low-energy strong interaction via precision X-ray spectroscopy. The SIDDHARTA-2 experiment at the DA$\Phi$NE collider employs high-performance Silicon Drift Detectors (SDDs) optimized for the 4-12 keV range to study light kaonic systems. In preparation for the EXKALIBUR phase, which targets heavier kaonic atoms, new 1 mm-thick SDDs have been developed with Politecnico di Milano and Fondazione Bruno Kessler. Their increased thickness enhances the quantum efficiency by a factor of about two at 30 keV while preserving excellent energy resolution. These detectors are also intended for VIP-3, the next-generation test of the Pauli Exclusion Principle (PEP). Building on VIP-2, which set the most stringent limits on PEP-violating $K_{\alpha}$ transitions in copper, VIP-3 will extend the search to heavier elements such as Ag, Sn, and Zr. Preliminary measurements demonstrate efficient detection up to 30 keV, supporting future high-precision studies of the kaon-nucleon interaction and PEP in heavier systems.

physics.ins-det

Precision Test of Bound-State QED at Intermediate-Z with Kaonic Neon

We report Dirac-Fock calculations of transition energies for kaonic neon (KNe). For the most intense line, the 7-6 transition, the calculated energy is 9450.28 eV, which includes a bound-state QED (BSQED) contribution of 12.66 eV. This is in excellent agreement with the recent SIDDHARTHA-2 measurement at DA$\Phi$NE of 9450.23 $\pm$ 0.37 (stat.) $\pm$ 1.50 (syst.) eV. With the QED shift far exceeding experimental uncertainty, these results establish kaonic atoms as powerful platforms for precision tests of BSQED in intermediate-Z systems.

physics.atom-ph

First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment

The LEGEND collaboration is searching for neutrinoless double beta ($0\nu\beta\beta$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0\nu\beta\beta$ decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of $0.5^{+0.3}_{-0.2}$ cts/(keV kg yr) in the $0\nu\beta\beta$ decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of $2.8 \times 10^{26}$ yr on the half-life of $0\nu\beta\beta$ decay, reveals no evidence for a signal and sets a new observed lower limit at $T^{0\nu}_{1/2} > 1.9 \times 10^{26}$ yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range $m_{\beta\beta} < 75-200$ meV, depending on the adopted nuclear matrix element.

hep-ex

Measurement of the inhomogeneity of the KATRIN tritium source electric potential by high-resolution spectroscopy of conversion electrons from $^{83m}$Kr

Precision spectroscopy of the electron spectrum of the tritium $\beta$-decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than 0.3$\,$eV (90$\,$% C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to distortions of the $\beta$-spectrum, which directly impact the neutrino-mass observable. This effect can be quantified through precision spectroscopy of the conversion-electrons of co-circulated metastable $^{83m}$Kr. Therefore, dedicated, several-weeks long measurement campaigns have been performed within the KATRIN data taking schedule. In this work, we infer the tritium source potential observables from these measurements, and present their implications for the neutrino-mass determination.

nucl-ex

First constraints on general neutrino interactions based on KATRIN data

The precision measurement of the tritium $\beta$-decay spectrum performed by the KATRIN experiment provides a unique way to search for general neutrino interactions (GNI). All theoretical allowed GNI terms involving neutrinos are incorporated into a low-energy effective field theory, and can be identified by specific signatures in the measured tritium $\beta$-spectrum. In this paper an effective description of the impact of GNI on the $\beta$-spectrum is formulated and the first constraints on the effective GNI parameters are derived based on the 4 million electrons collected in the second measurement campaign of KATRIN in 2019. In addition, constraints on selected types of interactions are investigated, thereby exploring the potential of KATRIN to search for more specific new physics cases, including a right-handed W boson, a charged Higgs or leptoquarks.

nucl-ex

Measurement of the electric potential and the magnetic field in the shifted analysing plane of the KATRIN experiment

The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after five years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN's main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The complex layout of electromagnetic fields in the SAP configuration requires a robust method of estimating these fields. We present in this paper a dedicated calibration measurement of the fields using conversion electrons of gaseous $^\mathrm{83m}$Kr, which enables the neutrino-mass measurements in the SAP configuration.

physics.ins-det

Silicon drift detectors for the Spectroscopy Focusing Array of eXTP

We present a silicon drift detector (SDD) system for the spectroscopy focusing array (SFA) of the enhanced X-ray timing and polarimetry (eXTP) mission. The SFA focuses on fast timing (time resolution below 10 {\mu}s) and good spectroscopy capabilities (energy resolution better than 180 eV @ 6 keV). The sensor, consisting of 19 hexagonally shaped pixels with a total sensitive area of ${5.05}\, cm^{2}$, is connected to three high time resolution spectroscopy (HTRS) ASICs, allowing a fast readout of the detector signals. The detector works in a Charge- Sensitive Amplifier configuration. We assembled a prototype detector module and present here its mechanical design, describe the used sensor, and report about its performance.

astro-ph.IM

Direct neutrino-mass measurement based on 259 days of KATRIN data

The fact that neutrinos carry a non-vanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass bears important relevance from particle physics to cosmology. In this work, we report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium $\beta$-decay close to the kinematic endpoint. Based on the first five neutrino-mass measurement campaigns, we derive a best-fit value of $m_\nu^{2} = {-0.14^{+0.13}_{-0.15}}~\mathrm{eV^2}$, resulting in an upper limit of $m_\nu < {0.45}~\mathrm{eV}$ at 90 % confidence level. With six times the statistics of previous data sets, amounting to 36 million electrons collected in 259 measurement days, a substantial reduction of the background level and improved systematic uncertainties, this result tightens KATRIN's previous bound by a factor of almost two.

nucl-ex

Kaonic lead feasibility measurement at DA{\Phi}NE to solve the charged kaon mass discrepancy

An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$\Phi$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.

physics.ins-det

SIDDHARTA-2 apparatus for kaonic atoms research on the DA$\Phi$NE collider

SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA$\Phi$NE electron-positron collider, of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p$\rightarrow$1s X-ray transitions in kaonic deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic hydrogen 2p$\rightarrow$1s X-ray transitions, the present apparatus has been upgraded with innovative Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider. We present a comprehensive description of the SIDDHARTA-2 setup including the optimization of its various components during the commissioning phase of the collider.

physics.ins-det

CdZnTe detectors tested at the DA{\Phi}NE collider for future kaonic atoms measurements

The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$\Phi$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam delivered by the at-rest decay of the $\phi$ meson. CdZnTe devices are ideal for detecting transitions toward both the upper and lower levels of intermediate-mass kaonic atoms, like kaonic carbon and aluminium, which have an important impact on the strangeness sector of nuclear physics. We present the results obtained in a set of preliminary tests conducted on DA$\Phi$NE, in view of measurements foreseen in 2024, with the twofold aim to tune the timing window required to reject the extremely high electromagnetic background, and to quantify the readout electronics saturation effect due to the high rate, when placed close to the Interaction Region (IR). In the first test we used commercial devices and electronics, while for the second one both were customized at the IMEM-CNR of Parma and the University of Palermo. The results confirmed the possibility of finding and matching a proper timing window where to identify the signal events and proved better performances, in terms of energy resolution, of the custom system. In both cases, strong saturation effects were confirmed, accounting for a loss of almost 90\% of the events, which will be overcome by a dedicated shielding structure foreseen for the final experimental setup.

physics.ins-det

Measurements of high-n transitions in intermediate mass kaonic atoms by SIDDHARTA-2 at DA$\mathrm{\Phi}$NE

The SIDDHARTA-2 experiment installed at the DA$\mathrm{\Phi}$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell with aluminium frames and Kapton walls, and are reported in this paper. These new kaonic atoms measurements add valuable input to the kaonic atoms transitions data base, which is used as a reference for theories and models of the low-energy strong interaction between antikaon and nuclei. Moreover, these results pave the way for future dedicated kaonic atoms measurements through the whole periodic table and to a new era for the antikaon-nuclei studies at low energy.

nucl-ex

New opportunities for kaonic atoms measurements from CdZnTe detectors

We present the tests performed by the SIDDHARTA-2 collaboration at the DA{\Phi}NE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an $^{241}Am$ source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of $\simeq10^{5-6}$, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.

physics.ins-det

Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy

The SIDDHARTA-2 experiment at the DA$\Phi$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.

physics.ins-det