C. Gargiulo

Publications and source records attributed to C. Gargiulo.

5 recordsLinked to original sources

Sensor operating point calibration and monitoring of the ALICE Inner Tracking System during LHC Run 3

The new Inner Tracking System (ITS2) of the ALICE experiment began operation in 2021 with the start of LHC Run 3. Compared to its predecessor, ITS2 offers substantial improvements in pointing resolution, tracking efficiency at low transverse momenta, and readout-rate capabilities. The detector employs silicon Monolithic Active Pixel Sensors (MAPS) featuring a pixel size of 26.88$\times$29.24 $\mu$m$^2$ and an intrinsic spatial resolution of approximately 5 $\mu$m. With a remarkably low material budget of 0.36% of radiation length ($X_{0}$) per layer in the three innermost layers and a total sensitive area of about 10 m$^2$, the ITS2 constitutes the largest-scale application of MAPS technology in a high-energy physics experiment and the first of its kind operated at the LHC. For stable data taking, it is crucial to calibrate different parameters of the detector, such as in-pixel charge thresholds and the masking of noisy pixels. The calibration of 24120 monolithic sensors, comprising a total of 12.6$\times$10$^{9}$ pixels, represents a major operational challenge. This paper presents the methods developed for the calibration of the ITS2 and outlines the strategies for monitoring and dynamically adjusting the detector's key performance parameters over time.

physics.ins-det

First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors

A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$\mu$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$\mu$m, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance. In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.

physics.ins-det

Active Radiation Shield for Space Exploration Missions (ARSSEM)

One of the major issues to be solved is the protection from the effects of ionizing radiation. Exploration mission, lasting two to three years in space, represents a very significant step from the point of view of radiation protection: both the duration (up to 5 times) and the intensity (up to 5 times) of the exposure to radiation are increased at the same time with respect to mission on the ISS reaching and sometime exceeding professional career limits. In this ARSSEM report, after reviewing the physics basis of the issue of radiation protection in space, we present results based for the first time on full physics simulation to understand the interplay among the the various factors determining the dose absorbed by the astronauts during a long duration mission: radiation composition and energy spectrum, 3D particle propagation through the magnetic field, secondary production on the spacecraft structural materia, dose sensitivity of the various parts of the human body. As first application of this approach, we use this analysis to study a new magnetic configuration based on Double Helix coil and exhibiting a number of interesting features which are suited to active shield application. The study also proposes a technology R&D roadmap for active radiation shield development which would match ESA decadal development strategy for human exploration of space.

physics.space-ph

AMICA, an astro-mapper for AMS

The Alpha Magnetic Spectrograph (AMS) is a composite particle detector to be accommodated on the International Space Station (ISS) in 2008. AMS is mainly devoted to galactic, charged Cosmic Rays studies, Antimatter and Dark Matter searches. Besides the main, classical physics goals, capabilities in the field of GeV and multi-GeV gamma astrophysics have been established and are under investigation by a number of groups. Due to the unsteadiness of the ISS platform, a star-mapper device is required in order to fully exploit the intrinsic arc-min angular resolution provided by the Silicon Tracker. A star-mapper is conceptually an imaging, optical instrument able to autonomously recognize a stellar field and to calculate its own orientation with respect to an inertial reference frame. AMICA (Astro Mapper for Instruments Check of Attitude) on AMS is responsible for providing real-time information that is going to be used off-line for compensating the large uncertainties in the ISS flight attitude and the structural degrees of freedom. In this paper, we describe in detail the AMICA sub-system and the accommodation/integration issues and the in-flight alignment procedure adopting identified galactic (pulsars) and extragalactic (AGNs) sources.

astro-ph