SearcharxivSearch

arXiv subjects

C. Gotti

Publications and source records attributed to C. Gotti.

At least 19 recordsLinked to original sources

The CROSS experiment: detector construction, background projection, and sensitivity to $^{100}$Mo $0\nu2\beta$ decay

The CROSS experiment to search for neutrinoless double-beta ($0\nu2\beta$) decay in $^{100}$Mo with the help of an array of scintillating cryogenic calorimeters, containing 4.9 kg of $^{100}$Mo, has been ongoing in a low-background setup at the Canfranc underground laboratory (Spain) since mid-November 2025. In this paper, we present the construction of the CROSS detector and the description of Geant4-based Monte Carlo simulations of expected background in the region of interest. The simulations predict the background index in a 100-keV-wide interval centered at the $Q$-value of $^{100}$Mo (3034 keV) on the level of 3.2(5) $\times$ 10$^{-3}$ cnts/keV/kg/yr. Taking into account an 18% deadtime induced by the muon veto cut and a typical 90% duty cycle of the facility, such background level would allow to reach the world-leading sensitivity to $^{100}$Mo $0\nu2\beta$ decay (lim $T_{1/2} \sim 4 \times 10^{24}$ yr) in 1 year of data taking. Considering conservatively a factor 3 (10) worse background index due to unpredictable radioactive contamination of construction materials and/or detector performance, a 2-yr-long operation of the CROSS array would be still compatible with the best (competitive) sensitivity to $0\nu2\beta$ decay in $^{100}$Mo.

physics.ins-det

Solar axion searches with RES-NOVA: projected sensitivity and first prototype limit

RES-NOVA is a cryogenic experiment based on PbWO4 scintillating bolometers produced from archaeological lead, originally designed to detect coherent elastic neutrino-nucleus scattering (CEvNS) from galactic core-collapse supernovae. We show that the same high-density, high-Z absorbers and sub-keV energy resolution make RES-NOVA an appealing probe of solar axions. We compute the expected signal from the Primakoff, ABC (atomic recombination and de-excitation, Bremsstrahlung, Compton), longitudinal-plasmon (LP), and 57Fe nuclear-line components of the solar axion flux, folded through the inverse-Primakoff and axioelectric detection channels in PbWO4, which probe the axion couplings to photons (g_a-gamma), electrons (g_ae), and nucleons (g_aN), respectively. We derive projected sensitivities for a 1 ton*y exposure of the RES-NOVA demonstrator in the (g_ae,g_a-gamma), (g_ae,g_aN), and (g_a-gamma,g_aN) planes. The projected reach in g_ae approaches that of XENONnT to within a factor of ~2, despite a background roughly four orders of magnitude higher, thanks to the large target mass, the high-Z enhancement of the axioelectric and inverse-Primakoff cross sections, and the sub-keV energy resolution. Because the inverse-Primakoff constraint on g_a-gamma relies on absorption rather than coherent conversion, it is independent of the axion mass, unlike bounds from magnetic helioscopes. We complement these projections with the first solar-axion exclusion limit obtained on real data with a 13 g PbWO4 prototype grown from archaeological lead, using a background-model-independent optimum-interval analysis. These results establish RES-NOVA as a promising multi-coupling probe of solar axions, with simultaneous sensitivity to g_ae, g_a-gamma and g_aN that is complementary to existing helioscope and direct-detection searches.

hep-ex

Probing large mass-splitting inelastic Dark Matter with RES-NOVA

Probing inelastic dark matter at large mass splittings requires heavy target nuclei, an extended recoil-energy range, and the high-velocity tail of the dark-matter distribution. We exploit these features with the RES-NOVA prototype detector, featuring a PbWO4 cryogenic calorimeter, produced from archaeological Pb and operated at the deep-underground laboratory of Gran Sasso of INFN (Italy), analyzing a 32.4 g day exposure over 2.5 keV - 1 MeV under both the Standard Halo Model (SHM) and a Large Magellanic Cloud (LMC)-motivated velocity distribution. We extend direct-detection constraints beyond the 330 keV reach of established technologies (e.g. Xe-based TPCs), probing splittings up to 510 (780) keV in the SHM (LMC) benchmark, while future exposures will probe new regions of the parameter space.

astro-ph.CO

Optimized filtering for pulse-shape based pile-up rejection applied to $0\nu\beta\beta$ search with $^{100}$Mo

Pile-up events, arising from the partial or complete temporal overlap of distinct signals, represent a major challenge in many areas of experimental physics where rare or low-rate processes are targeted. If not properly identified, pile-up can distort reconstructed observables, degrade energy resolution, and generate backgrounds that mimic genuine events of interest. This work presents an algorithm to obtain an optimized digital filter for the discrimination of pile-up events for detectors with known signal response and stationary noise power spectral density. It is developed in the context of the search for neutrinoless double beta decay with cryogenic Li$_{2}$$^{100}$MoO$_4$ detectors like CUPID, where pile-up induced background from $^{100}$Mo $2\nu\beta\beta$ is expected to be the leading background contribution. For this application, the new filter discriminant reduces the pile-up induced background (at 90% efficiency) by 31%, compared to an analysis with a reference method previously presented in Eur. Phys. J. C 83(5), 373 (2023). While the discussion is grounded in cryogenic calorimetric detectors, the concepts and methods described are broadly applicable to a wide class of detector technologies and experimental contexts.

physics.ins-det

Search for Sterile Neutrinos with CUPID-0

Sterile neutrinos are well-motivated extensions of the Standard Model, introduced to address fundamental questions such as the origin of neutrino masses and the nature of dark matter. Exploiting the precise data reconstruction achieved by the CUPID-0 experiment, we searched for spectral distortions in the double $\beta$-decay of $^{82}$Se compatible with the emission of a sterile neutrino. The analysis relies on the construction of a detailed background model down to 200 keV, enabling an accurate characterization of the main sources of contamination. Using a Zn$^{82}$Se exposure of 9.95 kg$\cdot$yr, we explored sterile neutrino mass hypotheses between 0.5 MeV and 1.5 MeV. No evidence for a signal was observed in any scenario; therefore, we derived 90% C.I. upper limits on the active-sterile mixing probability $\sin^2\theta$, obtaining the most stringent bound, $\sin^2\theta<8\times 10^{-3}$, for a sterile neutrino mass of 0.7 MeV.

nucl-ex

Comprehensive characterization of a YAG:Ce scintillator: light yield, alpha quenching and pulse-shape discrimination

Solid-state scintillators are widely used in particle and applied physics due to their versatility and resistance to diverse environments and operating conditions. This broad range of applications calls for thorough characterization of scintillating crystals. Among these materials, cerium-doped yttrium aluminum garnet (YAG:Ce) is a promising scintillator owing to its favorable timing characteristics, high light yield, good mechanical properties, and chemical stability. In this work, we report a comprehensive experimental characterization of a YAG:Ce crystal exposed to both $\gamma$ and $alpha$ radiation. We extract the scintillation decay time and light yield, and study their evolution from room temperature down to approximately $-50 ^\circ$ C. We perform a detailed investigation of the quenching factor for \al particles in the energy range from about $6$ MeV down to $1$ MeV, finding a value that decreases from approximately $0.17$ to $0.10$. We also explore the possibility of pulse-shape discrimination based on the different signal evolution depending on the interaction type, demonstrating strong classification capabilities. These results provide a detailed assessment of the performance of \YAG for radiation-detection applications and offer insight into its potential use in environments requiring reliable particle identification and stable response across a wide range of operating conditions.

physics.ins-det

Neutrino NSI in archaeological Pb

Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO$_4$ crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton$\cdot$y, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar $\nu$ interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to $0.5$ keV and $0.2$ keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, $\varepsilon_{ee}$, $\varepsilon_{\tau\tau}$, and $\varepsilon_{e\tau}$. A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton$\cdot$y.

hep-ph

A Wide Bandwidth Trans-impedance Amplifier for Picosecond-Scale SiPM Characterization in a Wide Temperature Range

Future high-energy physics experiments using SiPMs as photosensitive elements may require operation at low temperatures (down to 80 K) to measure single photons with high time resolution in a highly radioactive environment. This calls for a complete characterization of these sensors over a wide temperature range to find the best compromise between detector performance and cooling requirements. This paper presents the design of a transimpedance amplifier featuring high gain ($\sim 7500\ \text{V/A}$), very high speed ($<500\ \text{ps}$ rise time) and low input noise ($\lesssim 20\ \text{pA}/\sqrt{\text{Hz}}$), able to faithfully reproduce all the features of SiPM signals without affecting its noise or jitter performance. These features make the amplifier suitable for precise measurements of the time-of-arrival of single-photon signals, as well as gain and recovery time. This article provides a detailed and thorough analysis of the circuit. The network was simulated and measured in two configurations that differ in their open-loop gain and dominant pole frequencies. After selecting the best configuration for our purposes, the amplifier was characterized in detail at ambient temperature and at 80 K. Finally, we evaluated the amplifier using a SiPM operated at low over-voltage. While SiPMs are typically characterized at high over-voltage to enhance gain and minimize timing jitter, testing at low over-voltage allowed us to assess the amplifier's performance under more challenging and realistic conditions for single-photon timing.

physics.ins-det

Probing dark matter interactions with a RES-NOVA prototype cryogenic detector

We report on the operation of a 13 g PbWO$_4$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO$_4$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES-NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES-NOVA detection concept, validating the use of archaeological Pb-based PbWO$_4$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES-NOVA detectors employing larger target masses and advanced thermal readout technologies.

physics.ins-det

Operation of a tunable Power over Fiber system for light detectors down to 4.6 K

The Power over Fiber (PoF) technology delivers electrical power by transmitting laser light through a lightweight, non-conductive fiber optic cable to a remote photovoltaic optical converter, which in turn powers sensors or electrical devices. Among the several advantages offered by this solution are spark-free operation in the presence of electric fields, elimination of noise induced by power lines, immunity to electromagnetic interference, and high robustness in hostile environments. The R\&D for the application of PoF in cryogenic environments started at FNAL and BNL (USA) in 2020 to power the Photon Detection System of the DUNE Vertical Drift module. This paper presents the results obtained in the framework of Cryo-PoF project where we developed a single-laser input line system to power an electronic amplifier and the photosensors at cryogenic temperatures. Unlike the DUNE solution, our system allows tuning of the photosensor bias by adjusting the input laser power. We also demonstrate the operation of the optical converter at temperatures down to 4.6 K, opening the possibility of using this technology in a much broader range of applications.

physics.ins-det

Cosmic Ray Measurements Using Charge and Light Readout in a Pixelated Liquid Argon Time Projection Chamber

Liquid argon time projection chambers have emerged as a competitive technology for detecting solar neutrinos. The SoLAr collaboration was formed to explore argon detectors with pixelated light and charge readout, aiming for high detection efficiency and improved energy resolution. Building on the success of an initial prototype, we present results obtained with a second SoLAr prototype (V2), a $30 \times 30 \times 30$ cm$^{3}$ time projection chamber operated in a cryostat containing several hundred kilograms of liquid argon. We report measurements of cosmic-ray muons using both tracking and calorimetry from light and charge sensors, and we highlight the improved performance achieved through combined charge and light reconstruction. These results demonstrate the promise of dual-readout detectors and motivate future prototyping efforts toward kiloton-scale facilities.

physics.ins-det

Optimization of the X-Arapuca Photon Collection Efficiency for the DUNE Horizontal Drift Far Detector

The Deep Underground Neutrino Experiment (DUNE) Far Detector (FD) Photon Detection System (PDS) employs the X-Arapuca concept, a photon trapping system relying on reflective surfaces and dichroic filters. In this paper are reported measurements, performed at the University of Milano-Bicocca, aimed at increasing the FD Horizontal Drift (HD) PDS module efficiency. The baseline implementation of the X-Arapuca concept for the FD-HD PDS module is close to the DUNE requirements as demonstrated in the collaborations laboratory testing. However, an increased performance would provide a safety margin for a detector planned to be operated for 30 years, without possibility of performing maintenance. A higher detector performance would also benefit the DUNE low energy physics program. The already proven Milano-Bicocca setup has been utilized to test different PDS module configurations comparing them to the original baseline. Exploiting prior knowledge of the X-Arapuca components and Geant4 based optical simulations it has been possible to achieve up to an ~84% performance increase over the baseline design. In the following it is presented the testing procedure, the performed measurements and a brief discussion on the obtained results.

physics.ins-det

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

Measurement of the X-ARAPUCA's Absolute Photon Detection Efficiency for the Deep Underground Neutrino Experiment's Vertical Drift Far Detector

The DUNE experiment will implement a photon detection system composed of X-ARAPUCA (XA) devices. These trap incoming VUV photons by internal reflection in a wavelength shifter light guide to be collected onto silicon photomultiplier arrays, sensitive to visible light. In the baseline design, dichroic filters are used to prevent photons from escaping. The configuration proposed for DUNE's Vertical Drift (VD) module has been characterised in liquid argon for the first time using dedicated cryogenic setups developed at CIEMAT and INFN Naples. Additionally, several alternative configurations, based on the design optimisation studies of an R&D campaign, have been evaluated. The results show an efficiency of up to 4.5$\pm$4~% at 4.5~V overvoltage, representing a significant improvement over previous XA implementations. Most notably, configurations without dichroic filters show an improvement of up to 18~%, attributed to transmittance losses in the dichroic filters.

physics.ins-det

Muon veto system for the CROSS double-beta decay search experiment

In preparation to the CROSS experiment at the Canfranc underground laboratory (Spain) $-$ aiming to search for neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{100}$Mo using low-temperature detectors with heat-scintillation readout $-$ we report on development of a dedicated muon veto system. The need for the muon veto in CROSS is caused by a comparatively high residual cosmic muon flux at the experimental site ($\sim$20 $\mu$/m$^2$/h), being a dominant background in the region of interest (ROI) at $\sim$3 MeV. Thus, we installed the muon veto system around the CROSS low-background setup, forming four lateral, one top, and four bottom sectors. In this paper we describe the design, construction and operation of the CROSS muon veto system, as well as its optimization and validation by comparing dedicated Monte Carlo (MC) simulations of muons with low-temperature measurements in the setup. We demonstrate a stable operation of the veto system with the average trigger rates compatible with MC simulations. Also, we investigated two muon trigger logics based on coincidences with either 2 sectors or a single sector of the veto. The MC study shows that, in combination with the multiplicity cut of thermal detectors, these trigger logics allow to reject 99.2\% and 99.7\% of muon-induced events in the ROI, respectively. Despite a comparatively high dead time ($\sim$18\%) introduced by coincidences with any of nine sectors of the veto $-$ the adopted strategy $-$ the muon-induced background in the ROI of the CROSS experiment can be reduced down to $\sim$2 $\times 10^{-3}$ cnts/keV/kg/yr, i.e., an acceptable level compatible with a high-sensitivity $0\nu\beta\beta$ decay search foreseen in CROSS.

physics.ins-det

Characterization of the Li$_2$WO$_4$ crystal as a cryogenic scintillating calorimeter

A wide range of scintillating bolometers is under investigation for applications in the search for rare events and processes beyond the Standard Model. In this work, we report the first measurement of a natural, non-molybdenum-doped, lithium tungstate (LWO) crystal operated underground as a scintillating cryogenic calorimeter. The detector achieved a baseline energy resolution of 0.5 keV RMS with a low-energy threshold of about 1.5 keV. The simultaneous readout of heat and light enabled particle identification, revealing a clear separation between $\beta/\gamma$, $\alpha$, and nuclear recoil populations above 300 keV, with a light-yield-based particle discrimination better than $6\sigma$. These results, fully comparable with those achieved with other compounds in the field, demonstrate that LWO is a promising candidate for rare-event searches. In particular, the combination of excellent radio-purity (with U/Th levels below 0.5 mBq/kg) and sensitivity to neutron interactions via the $^6$Li(n,$\alpha$)$^3$H reaction makes this material an attractive option for next-generation experiments on dark matter, coherent elastic neutrino-nucleus scattering, and spin-dependent interactions.

physics.ins-det

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0\nu\beta\beta$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0\nu\beta\beta$ decay.

nucl-ex

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0\nu\beta\beta$) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the {\it Laboratori Nazionali del Gran Sasso}, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation $0\nu\beta\beta$ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

physics.ins-det