MIMAC : A micro-tpc matrix for directional detection of dark matter

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.

astro-ph.CO↗

Directional detection of Dark Matter with MIMAC: WIMP identification and track reconstruction

Directional detection is a promising Dark Matter search strategy. Indeed, WIMP-induced recoils present a direction dependence toward the Cygnus constellation, while background-induced recoils exhibit an isotropic distribution in the galactic rest frame. Taking advantage on these characteristic features and even in the presence of a sizeable background, we show for the first time the possibility to constrain the WIMP properties, both from particle and galactic halo physics, leading to an identification of non-baryonic Dark Matter. However, such results need highly accurate track reconstruction which should be reachable by the MIMAC detector using a dedicated readout combined with a likelihood analysis of recoiling nuclei.

astro-ph.CO↗

MIMAC : A micro-tpc matrix for directional detection of dark matter

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.

astro-ph.IM↗

Directional detection of non-baryonic dark matter with MIMAC

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low energy nuclei recoils obtained with a low energy neutron field are presented.

astro-ph.IM↗

Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC

Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.

astro-ph.IM↗

Directional detection of Dark Matter

Directional detection of galactic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, to take full advantage of this powerful detection method, one need to be able to extract information from an observed recoil map to identify a WIMP signal. We present a comprehensive formalism, using a map-based likelihood method allowing to recover the main incoming direction of the signal, thus proving its galactic origin, and the corresponding significance. Constraints are then deduced in the (sigma_n, m_chi) plane.

astro-ph.CO↗

Development of a front end ASIC for Dark Matter directional detection with MIMAC

A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC monitors 16 strips of pixels with charge preamplifiers and their time over threshold is provided in real time by current discriminators via two serializing LVDS links working at 320 MHz. The charge is summed over the 16 strips and provided via a shaper. These specifications have been chosen in order to build an auto triggered electronics. An acquisition board and the related software were developed in order to validate this methodology on a prototype chamber. The prototype detector presents an anode where 2 x 96 strips of pixels are monitored.

astro-ph.IM↗

Directional detection of galactic Dark Matter

Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.

astro-ph.CO↗

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

astro-ph.CO↗

A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)

We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are presented.

astro-ph.IM↗

Dark matter directional detection with MIMAC

MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are presented as a proof of concept.

astro-ph.IM↗

Micromegas micro-TPC for direct Dark Matter search with MIMAC

The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented, together with the first simulation of the track reconstruction. Recontruction of track of alpha from Radon impurities is shown as a first proof of concept.

astro-ph.CO↗

Low energy measurements with Helium Micromegas micro-TPC

The measurement of the ionization produced by particles in a medium presents a great interest in several fields from metrology to particule physics and cosmology. The ionization quenching factor is defined as the fraction of energy released by ionisation by a recoil in a medium compared with its kinetic energy. At low energy, in the range of a few keV, the ionization falls rapidly and systematic measurement are needed. We have developped an experimental setup devoted to the measurement of low energy (keV) ionization quenching factor for the MIMAC project. The ionization produced in the gas has been measured with a Micromegas detector filled with Helium gas mixture.