SearcharxivSearch

arXiv subjects

C. Hettich

Publications and source records attributed to C. Hettich.

3 recordsLinked to original sources

Generation of a superposition of odd photon number states for quantum information networks

We report on the experimental observation of quantum-network-compatible light described by a non-positive Wigner function. The state is generated by photon subtraction from a squeezed vacuum state produced by a continuous wave optical parametric amplifier. Ideally, the state is a coherent superposition of odd photon number states, closely resembling a superposition of weak coherent states (a Schroedinger cat), with the leading contribution from a single photon state in the low parametric gain limit. Light is generated in a nearly perfect spatial mode with a Fourier-limited frequency bandwidth which matches well atomic quantum memory requirements. The source is also characterized by high spectral brightness with about 10,000 and more events per second routinely generated. The generated state of light is the ultimate input state for testing quantum memories, quantum repeaters and linear optics quantum computers.

quant-ph

Measuring the quantum efficiency of single radiating dipoles using a scanning mirror

Using scanning probe techniques, we show the controlled manipulation of the radiation from single dipoles. In one experiment we study the modification of the fluorescence lifetime of a single molecular dipole in front of a movable silver mirror. A second experiment demonstrates the changing plasmon spectrum of a gold nanoparticle in front of a dielectric mirror. Comparison of our data with theoretical models allows determination of the quantum efficiency of each radiating dipole.

physics.optics

An ultra-sensitive pulsed balanced homodyne detector: Application to time-domain quantum measurements

A pulsed balanced homodyne detector has been developed for precise measurements of electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (> 85 dB) and low electronic noise (730 electrons per pulse) provide a signal to noise ratio of 14 dB for the measurement of the quantum noise of individual pulses. Measurements at repetition rates up to 1 MHz are possible. As a test, quantum tomography of the coherent state is performed and the Wigner function and the density matrix are reconstructed with a 99.5% fidelity. The detection system can also be used for ultrasensitive balanced detection in cw mode, e.g. for weak absorption measurements.

quant-ph