SearcharxivSearch

arXiv subjects

C. Husi

Publications and source records attributed to C. Husi.

4 recordsLinked to original sources

The Super Fine-Grained Detector for the T2K neutrino oscillation experiment

The magnetised near detector ND280 of the long-baseline neutrino experiment T2K has been upgraded to improve its detection performance and, consequently, enhance our understanding of neutrino-nucleus interactions, reducing the systematic uncertainties in measurements of the neutrino oscillation parameters. A key component of the upgrade is a novel segmented plastic scintillator detector, called the Super Fine-Grained Detector (SuperFGD), made of approximately 2 million optically isolated 1 cm$^3$ cubes read out by three orthogonal wavelength-shifting (WLS) fibres. Scintillation photons are detected by 55,888 Hamamatsu Multi-Pixel Photon Counters (MPPCs). The SuperFGD provides 3D images of neutrino interactions by tracking the final-state charged particles produced isotropically, including protons down to a threshold of around 330 MeV/$c$. The high light yield of SuperFGD greatly improves particle identification and the sub-nanosecond time resolution provides an excellent identification of Michel electrons. The SuperFGD is also able to detect neutrons from neutrino interactions and, for the first time in a neutrino experiment, to reconstruct their kinetic energy using a fine detector segmentation and by measuring the time-of-flight with sub-nanosecond precision. In this article the details of the detector design, construction and performance are described. The detector was installed in ND280 and successfully commissioned with cosmic data in 2023 and, later, with the T2K neutrino beam. The detector response has been characterised with the 2023 and 2024 data and the results are reported in this article.

physics.ins-det

Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

physics.ins-det

The design and construction of the MICE Electron-Muon Ranger

The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter installed in the beam line of the Muon Ionization Cooling Experiment (MICE). The experiment will demonstrate ionization cooling, an essential technology needed for the realization of a Neutrino Factory and/or a Muon Collider. The EMR is designed to measure the properties of low energy beams composed of muons, electrons and pions, and perform the identification particle-by-particle. The detector consists of 48 orthogonal layers of 59 triangular scintillator bars. The readout is implemented using FPGA custom made electronics and commercially available modules. This article describes the construction of the detector from its design up to its commissioning with cosmic data.

physics.ins-det

Electron-Muon Ranger: performance in the MICE Muon Beam

The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.

physics.ins-det