Searcharxiv⌕ Search

arXiv subjects

C. Labanti

Publications and source records attributed to C. Labanti.

98 records · Page 6Linked to original sources

Long-term AGILE monitoring of the puzzling gamma-ray source 3EG J1835+5918

We present the AGILE gamma-ray observations of the field containing the puzzling gamma-ray source 3EG J1835+5918. This source is one of the most remarkable unidentified EGRET sources. An unprecedentedly long AGILE monitoring of this source yields important information on the positional error box, flux evolution, and spectrum. 3EG J1835+5918 has been in the AGILE field of view several times in 2007 and 2008 for a total observing time of 138 days from 2007 Sept 04 to 2008 June 30 encompassing several weeks of continuous coverage. With an exposure time approximately twice that of EGRET, AGILE confirms the existence of a prominent gamma-ray source (AGL J1836+5926) at a position consistent with that of EGRET, although with a remarkably lower average flux value for photon energies greater than 100 MeV. A 5-day bin temporal analysis of the whole data set of AGL J1836+5926 shows some evidence for variability of the gamma-ray flux. The source spectrum between 100 MeV and 1 GeV can be fitted with a power law with photon index in the range 1.6-1.7, fully consistent with the EGRET value. The faint X-ray source RX J1836.2+5925 that has been proposed as a possible counterpart of 3EG J1835+5918 is well within the AGILE error box. Future continuous monitoring (both by AGILE and GLAST) is needed to confirm the gamma-ray flux variability and to unveil the source origin, a subject that is currently being pursued through a multiwavelength search for counterparts.

astro-ph↗

AGILE detection of a strong gamma-ray flare from the blazar 3C 454.3

We report the first blazar detection by the AGILE satellite. AGILE detected 3C 454.3 during a period of strongly enhanced optical emission in July 2007. AGILE observed the source with a dedicated repointing during the period 2007 July 24-30 with its two co-aligned imagers, the Gamma-Ray Imaging Detector and the hard X-ray imager Super-AGILE sensitive in the 30 MeV-50 GeV and 18-60 keV, respectively. Over the entire period, AGILE detected gamma-ray emission from 3C 454.3 at a significance level of 13.8-$σ$ with an average flux (E$>$100 MeV) of $(280 \pm 40) \times 10^{-8}$ photons cm$^{-2}$ s$^{-1}$. The gamma-ray flux appears to be variable towards the end of the observation. No emission was detected by Super-AGILE in the energy range 20-60 keV, with a 3-$σ$ upper limit of $2.3 \times 10^{-3}$ photons cm$^{-2}$ s$^{-1}$. The gamma-ray flux level of 3C 454.3 detected by AGILE is the highest ever detected for this quasar and among the most intense gamma-ray fluxes ever detected from Flat Spectrum Radio Quasars.

astro-ph↗

Design of a CZT Gamma-Camera for GRB and Fast Transient Follow-up: a Wide-Field-Monitor for the EDGE Mission

The success of the SWIFT/BAT and INTEGRAL missions has definitely opened a new window for follow-up and deep study of the transient gamma-ray sky. This now appears as the access key to important progresses in the area of cosmological research and deep understanding of the physics of compact objects. To detect in near real-time explosive events like Gamma-Ray bursts, thermonuclear flashes from Neutron Stars and other types of X-ray outbursts we have developed a concept for a wide-field gamma-ray coded mask instrument working in the range 8-200 keV, having a sensitivity of 0.4 ph cm-2 s-1 in 1s (15-150 keV) and arcmin location accuracy over a sky region as wide as 3sr. This scientific requirement can be achieved by means of two large area, high spatial resolution CZT detection planes made of arrays of relatively large (~1cm2) crystals, which are in turn read out as matrices of smaller pixels. To achieve such a wide Field-Of-View the two units can be placed at the sides of a S/C platform serving a payload with a complex of powerful X-ray instruments, as designed for the EDGE mission. The two units will be equipped with powerful signal read out system and data handling electronics, providing accurate on-board reconstruction of the source positions for fast, autonomous target acquisition by the X-ray telescopes.

astro-ph↗

GRB 070724B: the first Gamma Ray Burst localized by SuperAGILE and its Swift X-ray Afterglow

GRB 070724B is the first Gamma Ray Burst localized by SuperAGILE, the hard X-ray monitor aboard the AGILE satellite. The coordinates of the event were published $\sim 19$ hours after the trigger. The Swift X-Ray Telescope pointed at the SuperAGILE location and detected the X-ray afterglow inside the SuperAGILE error circle. The AGILE gamma-ray Tracker and Minicalorimeter did not detect any significant gamma ray emission associated with GRB 070724B in the MeV and GeV range, neither prompt nor delayed. Searches of the optical afterglow were performed by the Swift UVOT and the Palomar automated 60-inch telescopes without any significant detection. Similarly the Very Large Array did not detect a radio afterglow. This is the first GRB event with a firm upper limit in the 100 MeV -- 30 GeV energy range, associated with an X-ray afterglow.

astro-ph↗

INTEGRAL observations of the Crab pulsar

The paper presents the timing and spectral analysis of several observations of the Crab pulsar performed with INTEGRAL in the energy range 3-500 keV. All these observations, when summed together provide a high statistics data set which can be used for accurate phase resolved spectroscopy. A detailed study of the pulsed emission at different phase intervals is performed. The spectral distribution changes with phase showing a characteristic reverse S shape of the photon index. Moreover the spectrum softens with energy, in each phase interval, and this behavior is adequately modeled over the whole energy range 3-500 keV with a single curved law with a slope variable with Log(E), confirming the BeppoSAX results on the curvature of the pulsed emission. The bending parameter of the log-parabolic model is compatible with a single value of 0.14+/-0.02 over all phase intervals. Results are discussed within the three-dimensional outer gap model.

astro-ph↗

IBIS/PICsIT in-flight performances

PICsIT (Pixellated Imaging CaeSium Iodide Telescope) is the high energy detector of the IBIS telescope on-board the INTEGRAL satellite. PICsIT operates in the gamma-ray energy range between 175 keV and 10 MeV, with a typical energy resolution of 10% at 1 MeV, and an angular resolution of 12 arcmin within a \~100 square degree field of view, with the possibility to locate intense point sources in the MeV region at the few arcmin level. PICsIT is based upon a modular array of 4096 independent CsI(Tl) pixels, ~0.70 cm^2 in cross-section and 3 cm thick. In this work, the PICsIT on-board data handling and science operative modes are described. This work presents the in-flight performances in terms of background count spectra, sensitivity limit, and imaging capabilities.

astro-ph↗

IBIS/PICsIT Data and Analysis

The imager IBIS on board INTEGRAL is composed of two detector planes: ISGRI (15 keV - 1 MeV) and PICsIT (170 keV - 10 MeV). Here we describe the data structure of PICsIT and the instrument specific software, including the standard scientific analysis. Some examples of shadowgrams and spectra are shown, by using data collected during the End-to-End Tests of January 2002.

astro-ph↗

The AGILE Gamma-ray Astronomy Mission

We describe the AGILE gamma-ray astronomy satellite which has recently been selected as the first Small Scientific Mission of the Italian Space Agency. With a launch in 2002, AGILE will provide a unique tool for high-energy astrophysics in the 30 MeV - 50 GeV range before GLAST. Despite the much smaller weight and dimensions, the scientific performances of AGILE are comparable to those of EGRET.

astro-ph↗