Searcharxiv⌕ Search

arXiv subjects

C. Lee

Publications and source records attributed to C. Lee.

At least 37 records · Page 2Linked to original sources

Simulating MADMAX in 3D: Requirements for Dielectric Axion Haloscopes

We present 3D calculations for dielectric haloscopes such as the currently envisioned MADMAX experiment. For ideal systems with perfectly flat, parallel and isotropic dielectric disks of finite diameter, we find that a geometrical form factor reduces the emitted power by up to $30\,\%$ compared to earlier 1D calculations. We derive the emitted beam shape, which is important for antenna design. We show that realistic dark matter axion velocities of $10^{-3} c$ and inhomogeneities of the external magnetic field at the scale of $10\,\%$ have negligible impact on the sensitivity of MADMAX. We investigate design requirements for which the emitted power changes by less than $20\,\%$ for a benchmark boost factor with a bandwidth of $50\,{\rm MHz}$ at $22\,{\rm GHz}$, corresponding to an axion mass of $90\,μ{\rm eV}$. We find that the maximum allowed disk tilt is $100\,μ{\rm m}$ divided by the disk diameter, the required disk planarity is $20\,μ{\rm m}$ (min-to-max) or better, and the maximum allowed surface roughness is $100\,μ{\rm m}$ (min-to-max). We show how using tiled dielectric disks glued together from multiple smaller patches can affect the beam shape and antenna coupling.

hep-ex↗

MADMAX Status Report

In this report we present the status of the MAgnetized Disk and Mirror Axion eXperiment (MADMAX), the first dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. MADMAX will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 and 100 GHz corresponding to the axion mass. The present document orignated from a status report to the DESY PRC in 2019.

physics.ins-det↗

A new experimental approach to probe QCD axion dark matter in the mass range above 40$μ$eV

The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The axion mass range below 1 meV remains highly attractive and a well motivated region for dark matter axions. In this White Paper we present a description of a new experiment based on the concept of a dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. This MAgnetized Disk and Mirror Axion eXperiment (MADMAX) will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 to 100 GHz corresponding to the axion mass.

physics.ins-det↗

A free-floating or wide-orbit planet in the microlensing event OGLE-2019-BLG-0551

High-cadence observations of the Galactic bulge by the microlensing surveys led to the discovery of a handful of extremely short-timescale microlensing events that can be attributed to free-floating or wide-orbit planets. Here, we report the discovery of another strong free-floating planet candidate, which was found from the analysis of the gravitational microlensing event OGLE-2019-BLG-0551. The light curve of the event is characterized by a very short duration (<3 d) and a very small amplitude (< 0.1 mag). From modeling of the light curve, we find that the Einstein timescale, tE = 0.381 +/- 0.017 d, is much shorter, and the angular Einstein radius, thetaE = 4.35 +/- 0.34 uas, is much smaller than those of typical lensing events produced by stellar-mass lenses (tE ~ 20 d, thetaE ~ 0.3 mas), indicating that the lens is very likely to be a planetary-mass object. We conduct an extensive search for possible signatures of a companion star in the light curve of the event, finding no significant evidence for the putative host star. For the first time, we also demonstrate that the angular Einstein radius of the lens does not depend on blending in the low-magnification events with strong finite source effects.

astro-ph.EP↗

Extending light WIMP searches to single scintillation photons in LUX

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

astro-ph.CO↗

Enhanced negative nonlocal conductance in an interacting quantum dot connected to two ferromagnetic leads and one superconducting lead

In this paper, we investigate the electronic transport properties of a quantum dot (QD) connected to two ferromagnetic leads and one superconductor lead in the Kondo regime by means of the finite-$U$ slave boson mean field approach and nonequilibrium Green function technique. In this three-terminal hybrid nano-device, we will focus our attention on the joint effects of the Konod correlation, superconducting proximity pairing, and spin polarization of leads. It is found that: the superconducting proximity effect will suppress the linear local conductance (LLC) stemming from the weakened Kondo peak, and when its coupling $Γ_s$ is bigger than the tunnel-coupling $Γ$ of two normal leads, the linear cross conductance (LCC) becomes negative in the Kondo region; for antiparallel configuration, increasing spin polarization further suppresses LLC but enhances LCC, i.e. causing larger negative values of LCC, since it is benefit for emergence of cross Andreev reflection; On the contrary, for parallel configuration, with increasing spin polarization, the LLC descends and greatly widens with the appearance of shoulders, and eventually splits into four peaks, and meanwhile the LCC reduces relatively rapidly to the normal conductance.

cond-mat.mes-hall↗

First Results from the AMoRE-Pilot neutrinoless double beta decay experiment

The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.

hep-ex↗

Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from ${1.4}\times 10^{4}\;\mathrm{kg\,days}$ of target exposure in 2013, details of the calibration, event-reconstruction, modeling, and statistical tests that underlie the results are presented. Detector performance is characterized, including measured efficiencies, stability of response, position resolution, and discrimination between electron- and nuclear-recoil populations. Models are developed for the drift field, optical properties, background populations, the electron- and nuclear-recoil responses, and the absolute rate of low-energy background events. Innovations in the analysis include in situ measurement of the photomultipliers' response to xenon scintillation photons, verification of fiducial mass with a low-energy internal calibration source, and new empirical models for low-energy signal yield based on large-sample, in situ calibrations.

physics.ins-det↗

Chromatographic separation of radioactive noble gases from xenon

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes $^{85}$Kr and $^{39}$Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

physics.ins-det↗

Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.

physics.ins-det↗

First Searches for Axions and Axion-Like Particles with the LUX Experiment

The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90% C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are excluded. For galactic axion-like particles, values of gAe larger than 4.2 $\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16 keV/c$^{2}$. These are the most stringent constraints to date for these interactions.

astro-ph.CO↗

Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure

We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($σ_p$ = 5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.

astro-ph.CO↗

Parton Radiation and Fragmentation from LHC to FCC-ee

This document collects the proceedings of the "Parton Radiation and Fragmentation from LHC to FCC-ee" workshop (http://indico.cern.ch/e/ee\_jets16) held at CERN in Nov. 2016. The writeup reviews the latest theoretical and experimental developments on parton radiation and parton-hadron fragmentation studies --including analyses of LEP, B-factories, and LHC data-- with a focus on the future perspectives reacheable in $e^+e^-$ measurements at the Future Circular Collider (FCC-ee), with multi-ab$^{-1}$ integrated luminosities yielding 10$^{12}$ and 10$^{8}$ jets from Z and W bosons decays as well as 10$^5$ gluon jets from Higgs boson decays. The main topics discussed are: (i) parton radiation and parton-to-hadron fragmentation functions (splitting functions at NNLO, small-$z$ NNLL resummations, global FF fits including Monte Carlo (MC) and neural-network analyses of the latest Belle/BaBar high-precision data, parton shower MC generators), (ii) jet properties (quark-gluon discrimination, $e^+e^-$ event shapes and multi-jet rates at NNLO+N$^{n}$LL, jet broadening and angularities, jet substructure at small-radius, jet charge determination, $e^+e^-$ jet reconstruction algorithms), (iii) heavy-quark jets (dead cone effect, charm-bottom separation, gluon-to-$b\bar{b}$ splitting), and (iv) non-perturbative QCD phenomena (colour reconnection, baryon and strangeness production, Bose-Einstein and Fermi-Dirac final-state correlations, colour string dynamics: spin effects, helix hadronization).

hep-ph↗

Results from a search for dark matter in the complete LUX exposure

We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.

astro-ph.CO↗

Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).

physics.ins-det↗

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with $^3$H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.

physics.ins-det↗

Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data

We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $β$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.

astro-ph.CO↗

Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment

We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n~=~9.4~\times~10^{-41}~\text{cm}^2$ ($σ_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.

hep-ex↗