Searcharxiv⌕ Search

arXiv subjects

C. M. B. Monteiro

Publications and source records attributed to C. M. B. Monteiro.

At least 37 records · Page 2Linked to original sources

High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay $0νββ$. The feedthrough has been demonstrated to hold pressures up to 20~bar and sustain voltages as high as -65~kV, and the TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses.

physics.ins-det↗

Performance of an Optical TPC Geant4 Simulation with Opticks GPU-Accelerated Photon Propagation

We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47+/-0.02 and 181.39+/-0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.

physics.ins-det↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle $\cosθ$ among the two decay electrons, and the electron energy spectra, $T_1$ and $T_2$. In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{\cosθ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

hep-ex↗

Efficient noble gas purification using hot getters and gas circulation by convection

Noble gas radiation detectors with optical readout are gaining popularity in fields like astrophysics and particle physics due to their ability to produce both ionization and scintillation signals in response to ionizing radiation interaction. In addition, the amplification of primary ionization signals can be achieved by promoting secondary scintillation in the gas. Noble gas purity, especially concerning impurities like H$_{2}$O, N$_{2}$, O$_{2}$, CO$_{2}$, and hydrocarbons, greatly influences its performance. These impurities can cause the loss of primary electrons and quench the scintillation signal. A very high purity level of the gas is required. In the early 90's, a simple method was developed for noble gas purification in sealed, small volume (up to few litters) gas radiation detectors. Gas purification is achieved promoting gas circulation through Zr-based hot getters, simply maintaining the gas circulation by convection. The effectiveness of this method has been only confirmed by the energy resolutions achieved in those detectors, which were similar to that achieved in other high-performance noble gas detectors. In this work, we used waveform analysis of the primary and secondary scintillation signals and we were able to evaluate the impact of the attachment and quenching caused by impurities in one of our detectors filled with pure Xe, and estimate upper values for the impurity content in the gas. The maximum overall impurity concentration was estimated to be below 4 ppm, considering nearly all the impurities, and below 82 ppm if N$_{2}$ is considered. The electron lifetime was measured to be 2.1 $\pm$ 0.1 ms, in line with those achieved in other high-performance optical detectors.

physics.ins-det↗

Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.

hep-ex↗

Charge Amplification in Low Pressure CF4:SF6:He Mixtures with a Multi-Mesh ThGEM for Directional Dark Matter Searches

The CYGNO collaboration is developing next generation directional Dark Matter (DM) detection experiments, using gaseous Time Projection Chambers (TPCs), as a robust method for identifying Weakly Interacting Massive Particles (WIMPs) below the Neutrino Fog. SF6 is potentially ideal for this since it provides a high fluorine content, enhancing sensitivity to spin-dependent interactions and, as a Negative Ion Drift (NID) gas, reduces charge diffusion leading to improved positional resolution. CF4, although not a NID gas, has also been identified as a favourable gas target as it provides a scintillation signal which can be used for a complimentary light/charge readout approach. These gases can operate at low pressures to elongate Nuclear Recoil (NR) tracks and facilitate directional measurements. In principle, He could be added to low pressure SF6/CF4 without significant detriment to the length of 16S, 12C, and 19F recoils. This would improve the target mass, sensitivity to lower WIMP masses, and offer the possibility of atmospheric operation; potentially reducing the cost of a containment vessel. In this article, we present gas gain and energy resolution measurements, taken with a Multi-Mesh Thick Gaseous Electron Multiplier (MMThGEM), in low pressure SF6 and CF4:SF6 mixtures following the addition of He. We find that the CF4:SF6:He mixtures tested were able to produce gas gains on the order of 10^4 up to a total pressure of 100 Torr. These results demonstrate an order of magnitude improvement in charge amplification in NID gas mixtures with a He component.

physics.ins-det↗

Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe

The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.

physics.ins-det↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

physics.ins-det↗

Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from $^{83\mathrm{m}}$Kr calibration electron captures ($E\sim45$keV), the position of origin of low-energy events is determined to $2~$cm precision with bias $< 1$mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E$\geq$1.5MeV), yielding a precision of 3cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q$_{ββ}$ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

hep-ex↗

Unraveling xenon primary scintillation yield for cutting-edge rare event experiments

Xenon scintillation has been widely used in rare event detection experiments such as neutrinoless double beta decay, double electron captures and dark matter searches. Nonetheless, experimental values for primary scintillation yield in gaseous xenon (GXe) remain scarce and dispersed. The mean energy required to produce a scintillation photon, wsc, in GXe in the absence of recombination has been measured to be in the range of 34-111 eV. Lower values were reported for alpha-particles when compared to electrons produced by gamma- or x-rays. Since wsc is expected to be similar for x-, gamma-rays or electrons and alpha-particles, the above difference cannot be understood. In addition, one may pose the question of a dependence of wsc on photon energy. We carried out a systematic study on the absolute primary scintillation yield in GXe for electric fields in the 70-300 V/cm/bar range and for 1.2 bar supported by a robust geometrical efficiency simulation model. We were able to clear-out the above standing problems: we determined wsc for x/gamma-rays in the 5.9-60 keV range and alpha-particles in the 1.5-2.5 MeV range; no significant dependency neither on radiation type nor on energy was observed. Our values agree well with both state-of-art simulations and literature data obtained for alpha-particles. The discrepancy between our results and experimental values in the literature for x/gamma-rays is discussed in this work and attributed to unaddressed large systematic errors in previous studies. These findings can be extrapolated to other gases and have impact on experiments such as double beta decay, double electron capture and directional dark matter searches while also on potential future detection systems such as DUNE-Gas. Neglecting the 3rd continuum emission, as is the case of most of the literature values, a mean wsc-value of 38.7 [+- 0.6 (sta.)] [(- 7.2) (+ 7.7) (sys.)] eV was obtained.

astro-ph.IM↗

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0ν}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.

nucl-ex↗

NEXT-CRAB-0: A High Pressure Gaseous Xenon Time Projection Chamber with a Direct VUV Camera Based Readout

The search for neutrinoless double beta decay ($0νββ$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to $0νββ$ searches due to their intrinsically precise energy resolution and topological event identification capabilities. Scalability to ton- and multi-ton masses requires readout of large-area electroluminescent regions with fine spatial resolution, low radiogenic backgrounds, and a scalable data acquisition system. This paper presents a detector prototype that records event topology in an electroluminescent xenon gas TPC via VUV image-intensified cameras. This enables an extendable readout of large tracking planes with commercial devices that reside almost entirely outside of the active medium.Following further development in intermediate scale demonstrators, this technique may represent a novel and enlargeable method for topological event imaging in $0νββ$.

physics.ins-det↗

The CYGNO experiment, a directional detector for direct Dark Matter searches

The CYGNO project aims at the development of a high precision optical readout gaseous Tima Projection Chamber (TPC) for directional dark matter (DM) searches, to be hosted at Laboratori Nazionali del Gran Sasso (LNGS). CYGNO employs a He:CF$_4$ gas mixture at atmospheric pressure with a Gas Electron Multiplier (GEM) based amplification structure coupled to an optical readout comprised of sCMOS cameras and photomultiplier tubes (PMTs). This experimental setup allows to achieve 3D tracking and background rejection down to O(1) keV energy, to boost sensitivity to low WIMP masses. The characteristics of the optical readout approach in terms of the light yield will be illustrated along with the particle identification properties. The project timeline foresees, in the next 2-3 years, the realisation and installation of a 0.4 m$^3$ TPC in the underground laboratories at LNGS to act as a demonstrator. Finally, the studies of the expected DM sensitivities of the CYGNO demonstrator will be presented.

physics.ins-det↗

Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $μ$p atom diffusion in the hydrogen gas and the arrival time of the $μ$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $μ$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.

physics.atom-ph↗

A Compact Dication Source for Ba$^{2+}$ Tagging and Heavy Metal Ion Sensor Development

We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean $\mathrm{Ba^{2+}}$ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb$^{2+}$ and Cd$^{2+}$ also demonstrated for this purpose.

physics.ins-det↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm, and 450~nm. The results show that TPB-coated PTFE has a reflectance of approximately 92\% for thicknesses ranging from 5~mm to 10~mm at 450~nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5~mm to 10~mm does not affect significantly the light response at 128~nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10~mm can be used in particle physics detectors without compromising the light signal.

physics.ins-det↗

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

physics.ins-det↗

Laser excitation of the 1s-hyperfine transition in muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine state, {then} is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after the collisional deexcitation is used as a signature of a successful laser transition between hyperfine states. In this paper, we calculate the combined probability that a $μ$p atom initially in the singlet hyperfine state undergoes a laser excitation to the triplet state followed by a collisional-induced deexcitation back to the singlet state. This combined probability has been computed using the optical Bloch equations including the inelastic and elastic collisions. Omitting the decoherence effects caused by {the laser bandwidth and }collisions would overestimate the transition probability by more than a factor of two in the experimental conditions. Moreover, we also account for Doppler effects and provide the matrix element, the saturation fluence, the elastic and inelastic collision rates for the singlet and triplet states, and the resonance linewidth. This calculation thus quantifies one of the key unknowns of the HFS experiment, leading to a precise definition of the requirements for the laser system and to an optimization of the hydrogen gas target where $μ$p is formed and the laser spectroscopy will occur.

physics.atom-ph↗