A Vacuum-Compatible Cylindrical Inertial Rotation Sensor with Picoradian Sensitivity

We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adjusted remotely.

physics.ins-det

A vertical inertial sensor with interferometric readout

High precision interferometers such as gravitational-wave detectors require complex seismic isolation systems in order to decouple the experiment from unwanted ground motion. Improved inertial sensors for active isolation potentially enhance the sensitivity of existing and future gravitational-wave detectors, especially below 30 Hz, and thereby increase the range of detectable astrophysical signals. This paper presents a vertical inertial sensor which senses the relative motion between an inertial test mass suspended by a blade spring and a seismically isolated platform. An interferometric readout was used which introduces low sensing noise, and preserves a large dynamic range due to fringe-counting. The expected sensitivity is comparable to other state-of-the-art interferometric inertial sensors and reaches values of $10^{-10}\,\text{m}/\sqrt{\text{Hz}}$ at 100 mHz and $10^{-12}\,\text{m}/\sqrt{\text{Hz}}$ at 1 Hz. The potential sensitivity improvement compared to commercial L-4C geophones is shown to be about two orders of magnitude at 10 mHz and 100 mHz and one order of magnitude at 1 Hz. The noise performance is expected to be limited by thermal noise of the inertial test mass suspension below 10 Hz. Further performance limitations of the sensor, such as tilt-to-vertical coupling from a non-perfect levelling of the test mass and nonlinearities in the interferometric readout, are also quantified and discussed.

physics.ins-det

Interferometric sensing of a commercial geophone

We present a modified commercial L-4C geophone with interferometric readout that demonstrated a resolution 60 times lower than the included coil-magnet readout at low frequencies. The intended application for the modified sensor is in vibration isolation platforms that require improved performance at frequencies lower than 1 Hz. A controls and noise-model of an Advanced LIGO 'HAM-ISI' vibration isolation system was developed, and it shows that our sensor can reduce the residual vibration by a factor of 70 at 0.1 Hz

physics.ins-det

An Interactive Gravitational-Wave Detector Model for Museums and Fairs

In 2015 the first observation of gravitational waves marked a breakthrough in astrophysics, and in technological research and development. The discovery of a gravitational-wave signal from the collision of two black holes, a billion light-years away, received considerable interest from the media and public. We describe the development of a purpose-built exhibit explaining this new area of research to a general audience. The core element of the exhibit is a working Michelson interferometer: a scaled-down version of the key technology used in gravitational-wave detectors. The Michelson interferometer is integrated into a hands-on exhibit, which allows for user interaction and simulated gravitational-wave observations. An interactive display provides a self-guided explanation of gravitational-wave-related topics through video, animation, images and text. We detail the hardware and software used to create the exhibit and discuss two installation variants: an independent learning experience in a museum setting (the Thinktank Birmingham Science Museum), and a science-festival with the presence of expert guides (the 2017 Royal Society Summer Science Exhibition). We assess audience reception in these two settings, describe the improvements we have made given this information, and discuss future public-engagement projects resulting from this work. The exhibit is found to be effective in communicating the new and unfamiliar field of gravitational-wave research to general audiences. An accompanying website provides parts lists and information for others to build their own version of this exhibit.

physics.ed-ph

High Dynamic Range Spatial Mode Decomposition

Accurate readout of low-power optical higher-order spatial modes is of increasing importance to the precision metrology community. Mode sensors are used to prevent mode mismatches from degrading quantum and thermal noise mitigation strategies. Direct mode analysis sensors (MODAN) are a promising technology for real-time monitoring of arbitrary higher-order modes. We demonstrate MODAN with photo-diode readout to mitigate the typically low dynamic range of CCDs. We look for asymmetries in the response our sensor to break degeneracies in the relative alignment of the MODAN and photo-diode and consequently improve the dynamic range of the mode sensor. We provide a tolerance analysis and show methodology that can be applied for sensors beyond first-order spatial modes.

physics.ins-det

A compact, large-range interferometer for precision measurement and inertial sensing

We present a compact, fibre-coupled interferometer with high sensitivity and a large working range. We propose to use this interferometer as a readout mechanism for future inertial sensors, removing a major limiting noise source, and in precision positioning systems. The interferometers peak sensitivity is $2 \times 10^{-{14}}$ m/${\sqrt{\rm{Hz}}}$ at 70 Hz and $8 \times 10^{-{11}}$ m/$\sqrt{\rm{Hz}}$ at 10 mHz. If deployed on a GS-13 geophone, the resulting inertial sensing output will be dominated by suspension thermal noise from 50 mHz to 2 Hz.

astro-ph.IM

Huddle test measurement of a near Johnson noise limited geophone

In this paper the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground signal from the data. Using these two techniques, the measured sensor noise of the two geophone configurations matched calculated predictions remarkably well in the bandwidth of interest (0.01 Hz to 100 Hz). Low noise operational amplifiers OPA188 were utilized to amplify the L-4C geophone to give a sensor that was characterized to be near Johnson noise limited in the bandwidth of interest with a noise value of $10^{-11} \text{m}/\sqrt{\text{Hz}}$ at 1 Hz.

physics.ins-det

Impact of backscattered light in a squeezing-enhanced interferometric gravitational-wave detector

Squeezed states of light have been recently used to improve the sensitivity of laser interferometric gravitational-wave detectors beyond the quantum limit. To completely establish quantum engineering as a realistic option for the next generation of detectors, it is crucial to study and quantify the noise coupling mechanisms which injection of squeezed states could potentially introduce. We present a direct measurement of the impact of backscattered light from a squeezed-light source deployed on one of the 4 km long detectors of the Laser Interferometric Gravitational Wave Observatory (LIGO). We also show how our measurements inform the design of squeezed light sources compatible with the even more sensitive advanced detectors currently under construction, such as Advanced LIGO.

quant-ph

Balanced Homodyne Detection of Optical Quantum States at Audio-Band Frequencies and Below

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.