SearcharxivSearch

arXiv subjects

C. Macculi

Publications and source records attributed to C. Macculi.

13 recordsLinked to original sources

Thermalization of a SQUID chip at cryogenic temperature: Thermal conductance measurement for GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement between 20 and 200 mK

In the context of the ATHENA X-IFU Cryogenic AntiCoincidence Detector (CryoAC) development, we have studied the thermalization properties of a 2mm x 2mm SQUID chip. The chip is glued on a front-end PCB and operated on the cold stage of a dilution refrigerator (TBASE < 20 mK). We performed thermal conductance measurements by using different materials to glue the SQUID chip on the PCB. These have been repeated in subsequent cryostat runs, to highlight degradation effects due to thermal cycles. Here, we present the results obtained by glues and greases widely used in cryogenic environments, i.e. GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement.

astro-ph.IM

The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection

We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diagnostic purposes. We have illuminated the sample with 55Fe (6 keV line) and 241Am (60 keV line) radioactive sources, thus studying the detector response and the heater calibration accuracy at low energy. Furthermore, we have operated the sample in combination with a past-generation CryoAC prototype. Here, by analyzing the coincident detections between the two detectors, we have been able to characterize the background spectrum of the laboratory environment and disentangle the primary (i.e. cosmic muons) and secondaries (mostly secondary photons and electrons) signatures in the spectral shape.

astro-ph.IM

ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.

astro-ph.IM

Soft proton scattering at grazing incidence from X-ray mirrors: analysis of experimental data in the framework of the non-elastic approximation

Astronomical X-ray observatories with grazing incidence optics face the problem of pseudo-focusing of low energy protons from the mirrors towards the focal plane. Those protons constitute a variable, unpredictable component of the non X-ray background that strongly affects astronomical observations and a correct estimation of their flux at the focal plane is then essential. For this reason, we investigate how they are scattered from the mirror surfaces when impacting with grazing angles. We compare the non-elastic model of reflectivity of particles at grazing incidence proposed by Remizovich et al. (1980) with the few available experimental measurements of proton scattering from X-ray mirrors. We develop a semi-empirical analytical model based on the fit of those experimental data with the Remizovich solution. We conclude that the scattering probability weakly depends on the energy of the impinging protons and that the relative energy losses are necessary to correctly model the data. The model we propose assumes no dependence on the incident energy and can be implemented in particle transport simulation codes to generate, for instance, proton response matrices for specific X-ray missions. Further laboratory measurements at lower energies and on other mirror samples, such as ATHENA Silicon Pore Optics, will improve the resolution of the model and will allow us to build the proper proton response matrices for a wider sample of X-ray observatories.

astro-ph.IM

In-orbit background of X-ray microcalorimeters and its effects on observations

Methods.There are no experimental data about the background experienced by microcalorimeters in the L2 orbit, and thus the particle background levels were calculated by means of Monte Carlo simulations: we considered the original design configuration and an improved configuration aimed to reduce the unrejected background, and tested them in the L2 orbit and in the low Earth orbit, comparing the results with experimental data reported by other X-ray instruments.To show the results obtainable with the improved configuration we simulated the observation of a faint, high-redshift, point source (F[0.5-10 keV]~6.4E-16 erg cm-2 s-1, z=3.7), and of a hot galaxy cluster at R200 (Sb[0.5-2 keV]=8.61E-16 erg cm-2 s-1 arcmin-2,T=6.6 keV). Results.First we confirm that implementing an active cryogenic anticoincidence reduces the particle background by an order of magnitude and brings it close to the required level.The implementation and test of several design solutions can reduce the particle background level by a further factor of 6 with respect to the original configuration.The best background level achievable in the L2 orbit with the implementation of ad-hoc passive shielding for secondary particles is similar to that measured in the more favorable LEO environment without the passive shielding, allowing us to exploit the advantages of the L2 orbit.We define a reference model for the diffuse background and collect all the available information on its variation with epoch and pointing direction.With this background level the ATHENA mission with the X-IFU instrument is able to detect ~4100 new obscured AGNs with F>6.4E-16 erg cm-2 s-1 during three years, to characterize cluster of galaxies with Sb(0.5-2 keV)>9.4E-16 erg cm-2 s-1 sr-1 on timescales of 50 ks (500 ks) with errors <40% (<12%) on metallicity,<16% (4.8%) on temperature,2.6% (0.72%) on the gas density, and several single-element abundances.

astro-ph.IM

The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+

The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.

astro-ph.IM

Estimate of the impact of background particles on the X-Ray Microcalorimeter Spectrometer on IXO

We present the results of a study on the impact of particles of galactic (GCR) and solar origin for the X-ray Microcalorimeter Spectrometer (XMS) aboard an astronomical satellite flying in an orbit at the second Lagrangian point (L2). The detailed configuration presented in this paper is the one adopted for the International X-Ray Observatory (IXO) study, however the derived estimates can be considered a conservative limit for ATHENA, that is the IXO redefined mission proposed to ESA. This work is aimed at the estimate of the residual background level expected on the focal plane detector during the mission lifetime, a crucial information in the development of any instrumental configuration that optimizes the XMS scientific performances. We used the Geant4 toolkit, a Monte Carlo based simulator, to investigate the rejection efficiency of the anticoincidence system and assess the residual background on the detector.

astro-ph.IM

ORIGIN: Metal Creation and Evolution from the Cosmic Dawn

ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10, and beyond. The mission will answer questions such as: When were the first metals created? How does the cosmic metal content evolve? Where do most of the metals reside in the Universe? What is the role of metals in structure formation and evolution? To reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to study their local environments in their host galaxies. This requires the capability to slew the satellite in less than a minute to the GRB location. By studying the chemical composition and properties of clusters of galaxies we can extend the range of exploration to lower redshifts (z ~ 0.2). For this task we need a high-resolution spectral imaging instrument with a large field of view. Using the same instrument, we can also study the so far only partially detected baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the WHIM will be studied using absorption lines at low redshift in the spectra for GRBs.

astro-ph.IM

Effects of Thermal Fluctuations in the SPOrt Experiment

The role of systematic errors induced by thermal fluctuations is analyzed for the SPOrt experiment with the aim at estimating their impact on the measurement of the Cosmic Microwave Background Polarization (CMBP). The transfer functions of the antenna devices from temperature to data fluctuations are computed, by writing them in terms of both instrument and thermal environment parameters. In addition, the corresponding contamination maps are estimated, along with their polarized power spectra, for different behaviours of the instabilities. The result is that thermal effects are at a negligible level even for fluctuations correlated with the Sun illumination provided their frequency $f_{tf}$ is larger than that of the Sun illumination ($f_{day}$) by a factor $f_{tf} / f_{day} > 30$, which defines a requirement for the statistical properties of the temperature behaviour as well. The analysis with actual SPOrt operative parameters shows that the instrument is only weakly sensitive to temperature instabilities, the main contribution coming from the cryogenic stage. The contamination on the E-mode spectrum does not significantly pollute the CMBP signal and no specific data cleaning seems to be needed.

astro-ph

The Sky Polarization Observatory

SPOrt is an ASI-funded experiment specifically designed to measure the sky polarization at 22, 32 and 90 GHz, which was selected in 1997 by ESA to be flown on the International Space Station. Starting in 2006 and for at least 18 months, it will be taking direct and simultaneous measurements of the Stokes parameters Q and U at 660 sky pixels, with FWHM=7 degrees. Due to development efforts over the past few years, the design specifications have been significantly improved with respect to the first proposal. Here we present an up-to-date description of the instrument, which now warrants a pixel sensitivity of 1.7 microK for the polarization of the cosmic background radiation, assuming two years of observations. We discuss SPOrt scientific goals in the light of WMAP results, in particular in connection with the emerging double-reionization cosmological scenario.

astro-ph

An iterative destriping technique for diffuse background polarization data

We describe a simple but effective iterative procedure specifically designed to destripe Q and U Stokes parameter data as those collected by the SPOrt experiment onboard the International Space Station (ISS). The method is general enough to be useful for other experiments, both in polarization and total intensity. The only requirement for the algorithm to work properly is that the receiver knee frequency must be lower than the signal modulation frequency, corresponding in our case to the ISS orbit period. Detailed performances of the technique are presented in the context of the SPOrt experiment, both in terms of added rms noise and residual correlated noise.

astro-ph

The BaR-SPOrt Experiment

BaR-SPOrt (Balloon-borne Radiometers for Sky Polarisation Observations) is an experiment to measure the linearly polarized emission of sky patches at 32 and 90 GHz with sub-degree angular resolution. It is equipped with high sensitivity correlation polarimeters for simultaneous detection of both the U and Q stokes parameters of the incident radiation. On-axis telescope is used to observe angular scales where the expected polarization of the Cosmic Microwave Background (CMBP) peaks. This project shares most of the know-how and sophisticated technology developed for the SPOrt experiment onboard the International Space Station. The payload is designed to flight onboard long duration stratospheric balloons both in the Northern and Southern hemispheres where low foreground emission sky patches are accessible. Due to the weakness of the expected CMBP signal (in the range of microK), much care has been spent to optimize the instrument design with respect to the systematics generation, observing time efficiency and long term stability. In this contribution we present the instrument design, and first tests on some components of the 32 GHz radiometer.

astro-ph

SPOrt: an Experiment Aimed at Measuring the Large Scale Cosmic Microwave Background Polarization

SPOrt (Sky Polarization Observatory) is a space experiment to be flown on the International Space Station during Early Utilization Phase aimed at measuring the microwave polarized emission with FWHM = 7deg, in the frequency range 22-90 GHz. The Galactic polarized emission can be observed at the lower frequencies and the polarization of Cosmic Microwave Background (CMB) at 90 GHz, where contaminants are expected to be less important. The extremely low level of the CMB Polarization signal (< 1 uK) calls for intrinsically stable radiometers. The SPOrt instrument is expressly devoted to CMB polarization measurements and the whole design has been optimized for minimizing instrumental polarization effects. In this contribution we present the receiver architecture based on correlation techniques, the analysis showing its intrinsic stability and the custom hardware development carried out to detect such a low signal.

astro-ph