SearcharxivSearch

arXiv subjects

C. Menneglier

Publications and source records attributed to C. Menneglier.

4 recordsLinked to original sources

Development & first Performance evaluation of multi-element monolithic HPGe detector for X-ray spectroscopy

The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution X-ray spectroscopy in the hard X-ray regime, capable of handling high count rates (20-250 kcps/mm2) across a broad energy range (5-100 keV). We discuss here a complete laboratory-based characterization of the detector's performance, as well as an on-beam evaluation at the BM05 beamline of the ESRF synchrotron facility, using monochromatic X-rays in the 20-50 keV energy range. We provide a detailed performance assessment that also includes a phenomenological defect-depth estimation model.

physics.ins-det

The International Axion Observatory (IAXO): case, status and plans. Input to the European Strategy for Particle Physics

The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, covering scenarios motivated by astrophysical observations and potentially extending to axion dark matter models. Several studies in recent years have demonstrated that IAXO has the potential to probe a wide range of new physics beyond solar axions, including dark photons, chameleons, gravitational waves, and axions from nearby supernovae. IAXO will build upon the two-decade experience gained with CAST, the detailed studies for BabyIAXO, which is currently under construction, as well as new technologies. If, in contrast to expectations, solar axion searches with IAXO ``only'' result in limits on new physics in presently uncharted parameter territory, these exclusions would be very robust and provide significant constraints on models, as they would not depend on untestable cosmological assumptions.

hep-ph

An accurate solar axions ray-tracing response of BabyIAXO

BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at the focal spot. The aim of this article is to provide an accurate quantitative description of the different components (such as the magnet, optics, and X-ray detectors) involved in the detection of axions. Our efforts have focused on developing robust and integrated software tools to model these helioscope components, enabling future assessments of modifications or upgrades to any part of the IAXO axion helioscope and evaluating the potential impact on the experiment's sensitivity. In this manuscript, we demonstrate the application of these tools by presenting a precise signal calculation and response analysis of BabyIAXO's sensitivity to the axion-photon coupling. Though focusing on the Primakoff solar flux component, our virtual helioscope model can be used to test different production mechanisms, allowing for direct comparisons within a unified framework.

hep-ex

Microtomography on the ANATOMIX beamline at Synchrotron SOLEIL

The ANATOMIX beamline at Synchrotron SOLEIL, operational since 2018, is dedicated to hard X-ray full-field tomography techniques. Operating in a range of photon energies from approximately 5 to 50 keV, it offers both parallel-beam projection microtomography, in absorption and phase contrast, and nanotomography using a zone-plate transmission X-ray microscope. With these methods, the beamline covers a range of spatial resolution from 20 nm to 20 $μ$m, expressed in terms of useful pixel size. The variable beam size of up to 40 mm allows users to image large objects. Here we describe the microtomography instrumentation of the beamline.

physics.ins-det