SearcharxivSearch

arXiv subjects

C. O'Connor

Publications and source records attributed to C. O'Connor.

8 recordsLinked to original sources

Axion-Like Particle Search with a Hybrid Cherenkov-Scintillation Detector

This analysis presents the first proof-of-concept search for axion-like particles (ALPs) using a hybrid Cherenkov-scintillation detector at a beam-dump facility. The work is based on the Coherent CAPTAIN-Mills (CCM) experiment, a 10-ton liquid argon light collection detector located at Los Alamos National Laboratory. The CCM200 detector is instrumented with 200 photomultiplier tubes (PMTs), providing approximately 50% photocathode coverage. To enable optical discrimination, 80% of the PMTs are coated with a wavelength-shifting material while the remaining 20% are left uncoated. This configuration, combined with nanosecond-scale timing resolution, provides sensitivity to prompt Cherenkov radiation while maintaining efficient detection of liquid argon scintillation light [1, 2]. This analysis constructs four observables that exploit the Cherenkov emission and event topology expected from ALP-induced electromagnetic interactions. These observables are combined into a likelihood-ratio classifier that provides powerful rejection of steady-state backgrounds. No statistically significant excess above the expected background prediction is observed for $10^{-3}~\mathrm{MeV} < m_a < 10~\mathrm{MeV}$. Nevertheless, the improved background rejection enabled by hybrid Cherenkov-scintillation detection allows this analysis to surpass the sensitivity of the previous CCM120 search [3] despite less exposure and demonstrate the physics potential for hybrid Cherenkov-scintillation detectors.

hep-ex

First Event-by-Event Identification of Cherenkov Radiation from Sub-MeV Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon (LAr) detector by the Coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments 7 tons (fiducial volume) of LAr with 200 8-inch photomultiplier tubes (PMTs), 80% of which are coated in a wavelength shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as $-6 \leq t < 0$ ns relative to the event start time $t=0$, the uncoated PMTs are primarily sensitive to visible Cherenkov photons. Using gamma-rays from a $^{22}$Na source for production of sub-MeV electrons, we isolated prompt Cherenkov light with $>5\sigma$ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector, and represents a milestone in low-energy particle detector development.

physics.ins-det

Measurement of the Liquid Argon Scintillation Pulse Shape Using Differentiable Simulation in the Coherent CAPTAIN-Mills Experiment

The Coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and Beyond Standard Model physics signatures. Two hundred 8-inch photomultiplier tubes (PMTs) instrument the 7 ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM's light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with O(1) parts-per-million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte-Carlo simulation, and detailed PMT response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including: anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

physics.ins-det

Measurement of the Charge-Averaged Elastic Lepton-Proton Scattering Cross Section by the OLYMPUS Experiment

We report the first measurement of the average of the electron-proton and positron-proton elastic scattering cross sections. This lepton charge-averaged cross section is insensitive to the leading effects of hard two-photon exchange, giving more robust access to the proton's electromagnetic form factors. The cross section was extracted from data taken by the OLYMPUS experiment at DESY, in which alternating stored electron and positron beams were scattered from a windowless gaseous hydrogen target. Elastic scattering events were identified from the coincident detection of the scattered lepton and recoil proton in a large-acceptance toroidal spectrometer. The luminosity was determined from the rates of Møller, Bhabha and elastic scattering in forward electromagnetic calorimeters. The data provide some selectivity between existing form factor global fits and will provide valuable constraints to future fits.

nucl-ex

A novel technique for determining luminosity in electron-scattering/positron-scattering experiments from multi-interaction events

The OLYMPUS experiment measured the cross-section ratio of positron-proton elastic scattering relative to electron-proton elastic scattering to look for evidence of hard two-photon exchange. To make this measurement, the experiment alternated between electron beam and positron beam running modes, with the relative integrated luminosities of the two running modes providing the crucial normalization. For this reason, OLYMPUS had several redundant luminosity monitoring systems, including a pair of electromagnetic calorimeters positioned downstream from the target to detect symmetric Mø ller and Bhabha scattering from atomic electrons in the hydrogen gas target. Though this system was designed to monitor the rate of events with single Mø ller/Bhabha interactions, we found that a more accurate determination of relative luminosity could be made by additionally considering the rate of events with both a Mø ller/Bhabha interaction and a concurrent elastic $ep$ interaction. This method was improved by small corrections for the variance of the current within bunches in the storage ring and for the probability of three interactions occurring within a bunch. After accounting for systematic effects, we estimate that the method is accurate in determining the relative luminosity to within 0.36\%. This precise technique can be employed in future electron-proton and positron-proton scattering experiments to monitor relative luminosity between different running modes.

physics.ins-det

Hard Two-Photon Contribution to Elastic Lepton-Proton Scattering: Determined by the OLYMPUS Experiment

The OLYMPUS collaboration reports on a precision measurement of the positron-proton to electron-proton elastic cross section ratio, $R_{2γ}$, a direct measure of the contribution of hard two-photon exchange to the elastic cross section. In the OLYMPUS measurement, 2.01~GeV electron and positron beams were directed through a hydrogen gas target internal to the DORIS storage ring at DESY. A toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight scintillators detected elastically scattered leptons in coincidence with recoiling protons over a scattering angle range of $\approx 20\degree$ to $80\degree$. The relative luminosity between the two beam species was monitored using tracking telescopes of interleaved GEM and MWPC detectors at $12\degree$, as well as symmetric Møller/Bhabha calorimeters at $1.29\degree$. A total integrated luminosity of 4.5~fb$^{-1}$ was collected. In the extraction of $R_{2γ}$, radiative effects were taken into account using a Monte Carlo generator to simulate the convolutions of internal bremsstrahlung with experiment-specific conditions such as detector acceptance and reconstruction efficiency. The resulting values of $R_{2γ}$, presented here for a wide range of virtual photon polarization $0.456<ε<0.978$, are smaller than some hadronic two-photon exchange calculations predict, but are in reasonable agreement with a subtracted dispersion model and a phenomenological fit to the form factor data.

nucl-ex

Measurement and tricubic interpolation of the magnetic field for the OLYMPUS experiment

The OLYMPUS experiment used a 0.3 T toroidal magnetic spectrometer to measure the momenta of outgoing charged particles. In order to accurately determine particle trajectories, knowledge of the magnetic field was needed throughout the spectrometer volume. For that purpose, the magnetic field was measured at over 36,000 positions using a three-dimensional Hall probe actuated by a system of translation tables. We used these field data to fit a numerical magnetic field model, which could be employed to calculate the magnetic field at any point in the spectrometer volume. Calculations with this model were computationally intensive; for analysis applications where speed was crucial, we pre-computed the magnetic field and its derivatives on an evenly spaced grid so that the field could be interpolated between grid points. We developed a spline-based interpolation scheme suitable for SIMD implementations, with a memory layout chosen to minimize space and optimize the cache behavior to quickly calculate field values. This scheme requires only one-eighth of the memory needed to store necessary coefficients compared with a previous scheme [1]. This method was accurate for the vast majority of the spectrometer volume, though special fits and representations were needed to improve the accuracy close to the magnet coils and along the toroid axis.

physics.ins-det

The OLYMPUS Experiment

The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01~GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately $25^\circ$--$75^\circ$. Symmetric Møller/Bhabha calorimeters at $1.29^\circ$ and telescopes of GEM and MWPC detectors at $12^\circ$ served as luminosity monitors. A total luminosity of approximately 4.5~fb$^{-1}$ was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.

physics.ins-det