SearcharxivSearch

arXiv subjects

C. O'Sullivan

Publications and source records attributed to C. O'Sullivan.

At least 19 recordsLinked to original sources

Spectral Imaging with QUBIC: building astrophysical components from Time-Ordered-Data using Bolometric Interferometry

The detection of B-modes in the CMB polarization pattern is a major issue in modern cosmology and must therefore be handled with analytical methods that produce reliable results. We describe a method that uses the frequency dependency of the QUBIC synthesized beam to perform component separation at the map-making stage, to obtain more precise results. We aim to demonstrate the feasibility of component separation during the map-making stage in time domain space. This new technique leads to a more accurate description of the data and reduces the biases in cosmological analysis. The method uses a library for highly parallel computation which facilitates the programming and permits the description of experiments as easily manipulated operators. These operators can be combined to obtain a joint analysis using several experiments leading to maximized precision. The results show that the method works well and permits end-to-end analysis for the CMB experiments, and in particular, for QUBIC. The method includes astrophysical foregrounds, and also systematic effects like gain variation in the detectors. We developed a software pipeline that produces uncertainties on tensor-to-scalar ratio at the level of $σ(r) \sim 0.023$ using only QUBIC simulated data.

astro-ph.CO

Spectral Imaging with QUBIC: building frequency maps from Time-Ordered-Data using Bolometric Interferometry

The search for relics from the inflation era in the form of B-mode polarization of the CMB is a major challenge in cosmology. The main obstacle appears to come from the complexity of Galactic foregrounds that need to be removed. Multi-frequency observations are key to mitigating their contamination and mapping primordial fluctuations. We present spectral-imaging, a method to reconstruct sub-frequency maps of the CMB polarization within the instrument's physical bandwidth, a unique feature of Bolometric Interferometry that could be crucial for foreground mitigation as it provides an increased spectral resolution. Our technique uses the frequency evolution of the shape of the Bolometric Interferometer's synthesized beam to reconstruct frequency information from the time domain data. We reconstruct sub-frequency maps using an inverse problem approach based on detailed modeling of the instrument acquisition. We use external data to regularize the convergence of the estimator and account for bandpass mismatch and varying angular resolution. The reconstructed maps are unbiased and allow exploiting the spectral-imaging capacity of QUBIC. Using end-to-end simulations of the QUBIC instrument, we perform a cross-spectra analysis to extract a forecast on the tensor-to-scalar ratio constraint of $\sigma(r)= 0.0225$ after component separation.

astro-ph.CO

Identifying frequency decorrelated dust residuals in B-mode maps by exploiting the spectral capability of bolometric interferometry

Astrophysical polarized foregrounds represent the most critical challenge in Cosmic Microwave Background (CMB) B-mode experiments. Multi-frequency observations can be used to constrain astrophysical foregrounds to isolate the CMB contribution. However, recent observations indicate that foreground emission may be more complex than anticipated. We investigate how the increased spectral resolution provided by band splitting in Bolometric Interferometry (BI) through a technique called spectral imaging can help control the foreground contamination in the case of unaccounted Galactic dust frequency decorrelation along the line-of-sight. We focus on the next generation ground-based CMB experiment CMB-S4, and compare its anticipated sensitivities, frequency and sky coverage with a hypothetical version of the same experiment based on BI. We perform a Monte-Carlo analysis based on parametric component separation methods (FGBuster and Commander) and compute the likelihood on the recovered tensor-to-scalar ratio. The main result of this analysis is that spectral imaging allows us to detect systematic uncertainties on r from frequency decorrelation when this effect is not accounted for in component separation. Conversely, an imager would detect a biased value of r and would be unable to spot the presence of a systematic effect. We find a similar result in the reconstruction of the dust spectral index, where we show that with BI we can measure more precisely the dust spectral index also when frequency decorrelation is present. The in-band frequency resolution provided by BI allows us to identify dust LOS frequency decorrelation residuals where an imager of similar performance would fail. This opens the prospect to exploit this potential in the context of future CMB polarization experiments that will be challenged by complex foregrounds in their quest for B-modes detection.

astro-ph.CO

Measuring the CMB primordial B-modes with Bolometric Interferometry

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of Δν/ν \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.

astro-ph.CO

QUBIC VII: The feedhorn-switch system of the technological demonstrator

We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.

astro-ph.IM

QUBIC II: Spectro-Polarimetry with Bolometric Interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

astro-ph.IM

QUBIC III: Laboratory Characterization

A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.

astro-ph.IM

QUBIC I: Overview and ScienceProgram

The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.

astro-ph.IM

QUBIC V: Cryogenic system design and performance

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.

astro-ph.IM

QUBIC VIII: Optical design and performance

The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or planned experiments using the novel technique of bolometric interferometry. This technique takes advantage of the sensitivity of an imager and the systematic error control of an interferometer. A cold reflective optical combiner superimposes there-emitted beams from 400 aperture feedhorns on two focal planes. A shielding system composedof a fixed groundshield, and a forebaffle that moves with the instrument, limits the impact of local contaminants. The modelling, design, manufacturing and preliminary measurements of the optical components are described in this paper.

astro-ph.IM

The optical design of the LiteBIRD Middle and High Frequency Telescope

LiteBIRD is a JAXA strategic L-class mission devoted to the measurement of polarization of the Cosmic Microwave Background, searching for the signature of primordial gravitational waves in the B-modes pattern of the polarization. The onboard instrumentation includes a Middle and High Frequency Telescope (MHFT), based on a pair of cryogenically cooled refractive telescopes covering, respectively, the 89-224 GHz and the 166-448 GHz bands. Given the high target sensitivity and the careful systematics control needed to achieve the scientific goals of the mission, optical modeling and characterization are performed with the aim to capture most of the physical effects potentially affecting the real performance of the two refractors. We describe the main features of the MHFT, its design drivers and the major challenges in system optimization and characterization. We provide the current status of the development of the optical system and we describe the current plan of activities related to optical performance simulation and validation.

astro-ph.IM

QUBIC VI: cryogenic half wave plate rotator, design and performances

Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).

astro-ph.IM

QUBIC: the Q & U Bolometric Interferometer for Cosmology

The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.

astro-ph.IM

Thermal architecture for the QUBIC cryogenic receiver

QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.

astro-ph.IM

QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background

In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.

astro-ph.IM

QUBIC Technical Design Report

QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticipated polarized foregrounds (dust) reducing to zero the initial hope of finding sky regions clean enough to have a direct primordial B-modes observation. The QUBIC instrument is designed to address all aspects of this challenge with a novel kind of instrument, a Bolometric Interferometer, combining the background-limited sensitivity of Transition-Edge-Sensors and the control of systematics allowed by the observation of interference fringe patterns, while operating at two frequencies to disentangle polarized foregrounds from primordial B mode polarization. Its characteristics are described in details in this Technological Design Report.

astro-ph.IM

Latest Progress on the QUBIC Instrument

QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show the latest advances in the development of the architecture and the sub-systems of the first module of this instrument to be deployed in Dome Charlie Concordia base - Antarctica in 2015.

astro-ph.IM

The QUaD Galactic Plane Survey II: A Compact Source Catalog

We present a catalog of compact sources derived from the QUaD Galactic Plane Survey. The survey covers ~800 square degrees of the inner galaxy (|b|<4 degrees) in Stokes I, Q and U parameters at 100 and 150 GHz, with angular resolution 5 and 3.5 arcminutes. 505 unique sources are identified in I, of which 239 are spatially matched between frequency bands, with 50 (216) detected at 100 (150) GHz alone; 182 sources are identified as ultracompact HII (UCHII) regions. Approximating the distribution of total intensity source fluxes as a power-law, we find a slope of $γ_{S,100}=-1.8\pm0.4$ at 100 GHz, and $γ_{S,150}=-2.2\pm0.4$ at 150 GHz. Similarly, the power-law index of the source two-point angular correlation function is $γ_{θ,100}=-1.21\pm0.04$ and $γ_{θ,150}=-1.25\pm0.04$. The total intensity spectral index distribution peaks at $α_{I}\sim0.25$, indicating that dust emission is not the only source of radiation produced by these objects between 100 and 150 GHz; free-free radiation is likely significant in the 100 GHz band. Four sources are detected in polarized intensity P, of which three have matching counterparts in I. Three of the polarized sources lie close to the galactic center, Sagittarius A*, Sagittarius B2 and the Galactic Radio Arc, while the fourth is RCW 49, a bright HII region. An extended polarized source, undetected by the source extraction algorithm on account of its $\sim0.5^{\circ}$ size, is identified visually, and is an isolated example of large-scale polarized emission oriented distinctly from the bulk galactic dust polarization.

astro-ph.GA