Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

physics.ins-det

POEMMA-Balloon with Radio: A multi-messenger, multi-detector balloon payload

A review of the current status of the field of Ultra-High-Energy Cosmic Ray (UHECR) including a summary of remaining open questions was presented in the white paper "Ultra-High Energy Cosmic Rays: at the Intersection of the Cosmic and Energy Frontiers" (Astropart. Phys. 147 (2023) 102794; arXiv:2205.05845). The authors concluded that two types of next-generation detectors are needed to answer these questions: high-accuracy instruments and detectors that maximize exposure at the highest energies. The Probe Of Extreme Multi-Messenger Astrophysics (POEMMA), a proposed dual-satellite observatory, exemplifies the latter class and is designed to increase statistics of the highest-energy cosmic rays and to detect very-high-energy neutrinos following multi-messenger alerts. POEMMA-Balloon with Radio (PBR) implements a compact, balloon-borne version of the POEMMA concept, adapted for a Super-Pressure Balloon flight from Wanaka, New Zealand, with an expected campaign exceeding 20 days. PBR couples a wide field-of-view Schmidt telescope and a hybrid optical focal surface with a dedicated radio instrument to deliver simultaneous, complementary measurements of extensive air showers. The mission will validate the fluorescence detection strategy from space and raise technology readiness for a POEMMA-like space mission by observing UHECR-induced fluorescence light from suborbital altitudes, obtaining the first simultaneous optical Cherenkov and radio observations of high-altitude horizontal air showers above the cosmic-ray knee (E>3PeV), enabling energy-spectrum and composition studies at the PeV scale, and performing follow-ups of multi-messenger alerts to search for very-high-energy neutrinos via upward-going air showers. This paper summarizes the PBR payload and its expected performance.

astro-ph.IM

Search for Inelastic Boosted Dark Matter with the ICARUS Detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton$\cdot$year, collected by the ICARUS T-600 detector during its 2012--2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multi-particle dark sector with a U(1)$'$ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature which consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ($m_X, \epsilon$) parameter space for several selected optimal boosted dark matter mass sets.

hep-ex

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. A detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

physics.ins-det

Muon tomography imaging algorithms for nuclear threat detection inside large volume containers with the Muon Portal detector

Muon tomographic visualization techniques try to reconstruct a 3D image as close as possible to the real localization of the objects being probed. Statistical algorithms under test for the reconstruction of muon tomographic images in the Muon Portal Project are here discussed. Autocorrelation analysis and clustering algorithms have been employed within the context of methods based on the Point Of Closest Approach (POCA) reconstruction tool. An iterative method based on the log-likelihood approach was also implemented. Relative merits of all such methods are discussed, with reference to full Geant4 simulations of different scenarios, incorporating medium and high-Z objects inside a container.

physics.ins-det

Perspective for resonances in p-p collisions with the ALICE detector

The capability of the ALICE detector to reconstruct short-lived resonances from the very beginning of the LHC p-p program start-up was investigated, considering about 300,000 minimum bias p-p PYTHIA events at 900 GeV and 10 TeV, fully reconstructed under the hypothesis of a still misaligned detector. Only the information from track reconstruction was taken into account and no PID knowledge was considered. A reliable rho(770) yield estimation was possible in 900 GeV events. Moreover, in 300,000 p-p events at 10 TeV the signal for the phi-resonance could be extracted. A significance of 9 can be reached if only resonances with a transverse momentum larger than 1.5 GeV/c are considered. Moreover, even with this low statistics the phi signal is visible in events with a multiplicity as high as 100.