SearcharxivSearch

arXiv subjects

C. Pira

Publications and source records attributed to C. Pira.

At least 19 recordsLinked to original sources

Compilation of lessons learned from ESS cryomodule and benchmarking with projects in implementation phase

This document presents a deliverable of the project Innovate for Sustainable Accelerating Systems (iSAS), funded by the EU under its program HORIZON-INFRA-2023-TECH-01 via grant agreement n{\deg}101131435 (deliverable D16, WP5). It contains an analysis on elliptical cryomodules developed for the European Spallation Source (ESS) and a benchmark of high-beta cryomodules across six leading international facilities.

physics.acc-ph

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0\nu\beta\beta$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0\nu\beta\beta$ decay.

nucl-ex

Coherent oscillations in weakly anharmonic NbSe2 qubit

The functionalization of quantum devices to increase their performance and extend their fields of application is an extremely active research area. One of the most promising approaches is to replace aluminum with more performant materials. Within this context, van der Waals (vdW) materials are ideal candidates since they would allow to embed their unique properties into qubits. However, the realization of qubits based on vdW materials other than graphene is yet to be achieved. In this work we present a weakly anharmonic NbSe2 qubit. Our device exhibits a relaxation time T1 = 6.5 +\- 0.4 us which is roughly 2 orders of magnitude larger of other vdW qubits in addition to robustness to photon noise up to 5-10 thermal photons. Our work serves as a demonstrator of the advantage of integration of vdW materials into quantum technologies as well as serving as the first step toward the application of quantum non demolition photon detection protocols in the challenging field of dark matter search.

quant-ph

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0\nu\beta\beta$) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the {\it Laboratori Nazionali del Gran Sasso}, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation $0\nu\beta\beta$ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

physics.ins-det

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

hep-ex

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0\nu\beta\beta$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0\nu\beta\beta$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0\nu\beta\beta$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

physics.ins-det

Half-life and precision shape measurement of 2{\nu}{\beta}{\beta} decay of $^{130}$Te

We present a new measurement of the 2nbb half-life of 130Te (T1/2) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining T1/2 = (9.32 +0.05 -0.04 (stat.) +0.07 -0.07 (syst.)) x10^20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2nbb formalism to 130Te. Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0nbb searches.

nucl-ex

Search for fractionally charged particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.

hep-ex

Data-driven background model for the CUORE experiment

We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.

nucl-ex

Constraints on Lepton Number Violation with the 2 tonne$\cdot$yr CUORE Dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay ($0\nu \beta\beta$) may help explain this asymmetry, while unveiling the Majorana nature of the neutrino. The CUORE experiment searches for $0\nu \beta\beta$ of $^{130}$Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of $0\nu \beta\beta$ and place a lower limit on the half-life of $T_{1/2} >3.5 \times$ 10$^{25}$~years (90\% C.I.) with over 2~tonne$\cdot$year TeO$_2$ exposure. The tools and techniques developed for this result and the 5 year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for a future-generation experiment capable of searching for $0\nu \beta\beta$ across multiple isotopes.

nucl-ex

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

physics.ins-det

New direct limit on neutrinoless double beta decay half-life of $^{128}$Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0$\nu\beta\beta$) decay. Its main goal is to investigate this decay in $^{130}$Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. In this work, we present our first results on the search for \nbb decay of $^{128}$Te, the Te isotope with the second highest natural isotopic abundance. We find no evidence for this decay, and using a Bayesian analysis we set a lower limit on the $^{128}$Te \nbb decay half-life of T$_{1/2} > 3.6 \times 10^{24}$ yr (90\% CI). This represents the most stringent limit on the half-life of this isotope, improving by over a factor 30 the previous direct search results, and exceeding those from geochemical experiments for the first time.

nucl-ex

Next-Generation Superconducting RF Technology based on Advanced Thin Film Technologies and Innovative Materials for Accelerator Enhanced Performance and Energy Reach

Superconducting RF is a key technology for future particle accelerators, now relying on advanced surfaces beyond bulk Nb for a leap in performance and efficiency. The SRF thin film strategy aims at transforming the current SRF technology by using highly functional materials, addressing all the necessary functions. The community is deploying efforts in three research thrusts to develop next-generation thin-film based cavities. Nb on Cu cavities are developed to perform as good as or better than bulk Nb at reduced cost and with better thermal stability. Recent results showing improved accelerating field and dramatically reduced Q slope show their potential for many applications. The second research thrust is to develop cavities coated with materials that can operate at higher temperatures or sustain higher fields. Proof of principle has been established for the merit of Nb3Sn for SRF application. Research is now needed to further exploit the material and reach its full potential with novel deposition techniques. The third line of research is to push SRF performance beyond the capabilities of the superconductors alone with multilayered coatings. In parallel, developments are needed to provide quality substrates, cooling schemes and cryomodule design tailored to thin film cavities. Recent results in these three research thrusts suggest that SRF thin film technologies are at the eve of a technological revolution. For them to mature, active community support and sustained funding are needed to address fundamental developments supporting material deposition techniques, surface and RF research, technical challenges associated with scaling and industrialization. With dedicated and sustained investment, next-generation thin-film based cavities will become a reality with high performance and efficiency, facilitating energy sustainable science while enabling higher luminosity, and higher energy.

physics.acc-ph

Search for Neutrinoless $\beta^+EC$ Decay of $^{120}$Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0\nu\beta\beta$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0\nu\beta^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 \nu \beta\beta$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $\gamma$s make $0\nu\beta^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0\nu\beta^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

nucl-ex

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 \nu \beta \beta$) decay. Here we show results from the search for $0 \nu \beta \beta$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 \nu \beta \beta$ decay and set a lower bound of $T_{1/2}^{0 \nu} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

nucl-ex

Search for Double-Beta Decay of $\mathrm{^{130}Te}$ to the $0^+$ States of $\mathrm{^{130}Xe}$ with CUORE

The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ($0\nu\beta\beta$) in the isotope $\mathrm{^{130}Te}$. In this work we present the latest results on two searches for the double beta decay (DBD) of $\mathrm{^{130}Te}$ to the first $0^{+}_2$ excited state of $\mathrm{^{130}Xe}$: the $0\nu\beta\beta$ decay and the Standard Model-allowed two-neutrinos double beta decay ($2\nu\beta\beta$). Both searches are based on a 372.5 kg$\times$yr TeO$_2$ exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90\% Credible Interval (C.I.) of the given searches were estimated as $\mathrm{S^{0\nu}_{1/2} = 5.6 \times 10^{24} \: \mathrm{yr}}$ for the ${0\nu\beta\beta}$ decay and $\mathrm{S^{2\nu}_{1/2} = 2.1 \times 10^{24} \: \mathrm{yr}}$ for the ${2\nu\beta\beta}$ decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $90\%$ C.I. on the decay half lives is obtained as: $\mathrm{(T_{1/2})^{0\nu}_{0^+_2} > 5.9 \times 10^{24} \: \mathrm{yr}}$ for the $0\nu\beta\beta$ mode and $\mathrm{(T_{1/2})^{2\nu}_{0^+_2} > 1.3 \times 10^{24} \: \mathrm{yr}}$ for the $2\nu\beta\beta$ mode. These represent the most stringent limits on the DBD of $^{130}$Te to excited states and improve by a factor $\sim5$ the previous results on this process.

nucl-ex

Measurement of the 2$\nu\beta\beta$ Decay Half-life of $^{130}$Te with CUORE

We measured two-neutrino double beta decay of $^{130}$Te using an exposure of 300.7 kg$\cdot$yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced uncertainty: $T^{2\nu}_{1/2} = 7.71^{+0.08}_{-0.06}\mathrm{(stat.)}^{+0.12}_{-0.15}\mathrm{(syst.)}\times10^{20}$ yr. This measurement is the most precise determination of the $^{130}$Te 2$\nu\beta\beta$ decay half-life to date.

nucl-ex