Searcharxiv⌕ Search

arXiv subjects

C. Regenfus

Publications and source records attributed to C. Regenfus.

At least 37 records · Page 2Linked to original sources

First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches

ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.

physics.ins-det↗

The ArDM experiment

The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.

physics.ins-det↗

Evidence for $πK$-atoms with DIRAC

We present evidence for the first observation of electromagnetically bound $π^\pm K^\mp$-pairs ($πK$-atoms) with the DIRAC experiment at the CERN-PS. The $πK$-atoms are produced by the 24 GeV/c proton beam in a thin Pt-target and the $π^\pm$ and $K^\mp$-mesons from the atom dissociation are analyzed in a two-arm magnetic spectrometer. The observed enhancement at low relative momentum corresponds to the production of 173 $\pm$ 54 $πK$-atoms. The mean life of $πK$-atoms is related to the s-wave $πK$-scattering lengths, the measurement of which is the goal of the experiment. From these first data we derive a lower limit for the mean life of 0.8 fs at 90% confidence level.

hep-ex↗

Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector

To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.

physics.ins-det↗

The Argon Dark Matter Experiment (ArDM)

The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nuclei. These events producing a recoiling nucleus will be discerned by their light to charge ratio, as well as the time structure of the scintillation light. The experiment is presently under construction and will be commissioned on surface at CERN. Here we describe the detector concept and give a short review on the main detector components.

physics.ins-det↗

Production of Slow Protonium in Vacuum

We describe how protonium, the quasi-stable antiproton-proton bound system, has been synthesized following the interaction of antiprotons with the molecular ion H$_2^+$ in a nested Penning trap environment. From a careful analysis of the spatial distributions of antiproton annihilation events in the ATHENA experiment, evidence is presented for protonium production with sub-eV kinetic energies in states around $n$ = 70, with low angular momenta. This work provides a new 2-body system for study using laser spectroscopic techniques.

hep-ex↗

Evidence For The Production Of Slow Antiprotonic Hydrogen In Vacuum

We present evidence showing how antiprotonic hydrogen, the quasistable antiproton-proton (pbar-p) bound system, has been synthesized following the interaction of antiprotons with the hydrogen molecular ion (H2+) in a nested Penning trap environment. From a careful analysis of the spatial distributions of antiproton annihilation events, evidence is presented for antiprotonic hydrogen production with sub-eV kinetic energies in states around n=70, and with low angular momenta. The slow antiprotonic hydrogen may be studied using laser spectroscopic techniques.

hep-ex↗

Luminescence quenching of the triplet excimer state by air traces in gaseous argon

While developing a liquid argon detector for dark matter searches we investigate the influence of air contamination on the VUV scintillation yield in gaseous argon at atmospheric pressure. We determine with a radioactive alpha-source the photon yield for various partial air pressures and different reflectors and wavelength shifters. We find for the fast scintillation component a time constant tau1= 11.3 +- 2.8 ns, independent of gas purity. However, the decay time of the slow component depends on gas purity and is a good indicator for the total VUV light yield. This dependence is attributed to impurities destroying the long-lived argon excimer states. The population ratio between the slowly and the fast decaying excimer states is determined for alpha-particles to be 5.5 +-0.6 in argon gas at 1100 mbar and room temperature. The measured mean life of the slow component is tau2 = 3.140 +- 0.067 microsec at a partial air pressure of 2 x 10-6 mbar.

physics.ins-det↗

Design and performance of the silicon sensors for the CMS barrel pixel detector

The CMS experiment at the LHC includes a hybrid silicon pixel detector for the reconstruction of charged tracks and of the interaction vertices. The barrel region consists of n-in-n sensors with 100X150 um^2 cell size processed on diffusion oxygenated float zone silicon. A biasing grid is implemented and pixel isolation is achieved with the moderated p-spray technique. An extensive test program was carried out on the H2 beam line of the CERN SPS. In this paper we describe the sensor layout, the beam test setup and the results obtained with both irradiated and non-irradiated prototype devices. Measurements of charge collection, hit detection efficiency, Lorentz angle and spatial resolution are presented.

physics.ins-det↗

Simulation of Heavily Irradiated Silicon Pixel Detectors

We show that doubly peaked electric fields are necessary to describe grazing-angle charge collection measurements of irradiated silicon pixel sensors. A model of irradiated silicon based upon two defect levels with opposite charge states and the trapping of charge carriers can be tuned to produce a good description of the measured charge collection profiles in the fluence range from 0.5x10^{14} Neq/cm^2 to 5.9x10^{14} Neq/cm^2. The model correctly predicts the variation in the profiles as the temperature is changed from -10C to -25C. The measured charge collection profiles are inconsistent with the linearly-varying electric fields predicted by the usual description based upon a uniform effective doping density. This observation calls into question the practice of using effective doping densities to characterize irradiated silicon. The model is now being used to calibrate pixel hit reconstruction algorithms for CMS.

physics.ins-det↗

Observation, modeling, and temperature dependence of doubly peaked electric fields in irradiated silicon pixel sensors

We show that doubly peaked electric fields are necessary to describe grazing-angle charge collection measurements of irradiated silicon pixel sensors. A model of irradiated silicon based upon two defect levels with opposite charge states and the trapping of charge carriers can be tuned to produce a good description of the measured charge collection profiles in the fluence range from 0.5x10^{14} Neq/cm^2 to 5.9x10^{14} Neq/cm^2. The model correctly predicts the variation in the profiles as the temperature is changed from -10C to -25C. The measured charge collection profiles are inconsistent with the linearly-varying electric fields predicted by the usual description based upon a uniform effective doping density. This observation calls into question the practice of using effective doping densities to characterize irradiated silicon.

physics.ins-det↗

High Efficiency Detection of Argon Scintillation Light of 128nm Using LAAPDs

The possibility of efficient collection and detection of vacuum ultraviolet light as emitted by argon, krypton, and xenon gas is studied. Absolute quantum efficiencies of large area avalanche photodiodes (LAAPDs) are derived at these wavelengths. VUV light of wavelengths down to the 128nm of Ar emission is shown to be detectable with silicon avalanche photodiodes at quantum efficiencies above 42%. Flexible Mylar foil overcoated with Al+MgF$_2$ is measured to have a specular reflectivity of $\sim$91% at argon emission wavelength. Low-pressure argon gas is shown to emit significant amounts of non-UV radiation. The average energy expenditure for the creation of non-UV photons in argon gas at this pressure is measured to be below 378 eV.

physics.ins-det↗

A double junction model of irradiated silicon pixel sensors for LHC

In this paper we discuss the measurement of charge collection in irradiated silicon pixel sensors and the comparison with a detailed simulation. The simulation implements a model of radiation damage by including two defect levels with opposite charge states and trapping of charge carriers. The modeling proves that a doubly peaked electric field generated by the two defect levels is necessary to describe the data and excludes a description based on acceptor defects uniformly distributed across the sensor bulk. In addition, the dependence of trap concentrations upon fluence is established by comparing the measured and simulated profiles at several fluences and bias voltages.

physics.ins-det↗

Extraction of electric field in heavily irradiated silicon pixel sensors

A new method for the extraction of the electric field in the bulk of heavily irradiated silicon pixel sensors is presented. It is based on the measurement of the Lorentz deflection and mobility of electrons as a function of depth. The measurements were made at the CERN H2 beam line, with the beam at a shallow angle with respect to the pixel sensor surface. The extracted electric field is used to simulate the charge collection and the Lorentz deflection in the pixel sensor. The simulated charge collection and the Lorentz deflection is in good agreement with the measurements both for non-irradiated and irradiated up to 1E15 neq/cm2 sensors.

physics.ins-det↗

ATHENA -- First Production of Cold Antihydrogen and Beyond

Atomic systems of antiparticles are the laboratories of choice for tests of CPT symmetry with antimatter. The ATHENA experiment was the first to report the production of copious amounts of cold antihydrogen in 2002. This article reviews some of the insights that have since been gained concerning the antihydrogen production process as well as the external and internal properties of the produced anti-atoms. Furthermore, the implications of those results on future prospects of symmetry tests with antimatter are discussed.

hep-ex↗

Cold-Antimatter Physics

The CPT theorem and the Weak Equivalence Principle are foundational principles on which the standard description of the fundamental interactions is based. The validity of such basic principles should be tested using the largest possible sample of physical systems. Cold neutral antimatter (low-energy antihydrogen atoms) could be a tool for testing the CPT symmetry with high precision and for a direct measurement of the gravitational acceleration of antimatter. After several years of experimental efforts, the production of low-energy antihydrogen through the recombination of antiprotons and positrons is a well-established experimental reality. An overview of the ATHENA experiment at CERN will be given and the main experimental results on antihydrogen formation will be reviewed.

hep-ex↗

Fluence Dependence of Charge Collection of irradiated Pixel Sensors

The barrel region of the CMS pixel detector will be equipped with ``n-in-n'' type silicon sensors. They are processed on DOFZ material, use the moderated p-spray technique and feature a bias grid. The latter leads to a small fraction of the pixel area to be less sensitive to particles. In order to quantify this inefficiency prototype pixel sensors irradiated to particle fluences between $4.7\times 10^{13}$ and $2.6\times 10^{15} \Neq$ have been bump bonded to un-irradiated readout chips and tested using high energy pions at the H2 beam line of the CERN SPS. The readout chip allows a non zero suppressed analogue readout and is therefore well suited to measure the charge collection properties of the sensors. In this paper we discuss the fluence dependence of the collected signal and the particle detection efficiency. Further the position dependence of the efficiency is investigated.

physics.ins-det↗

Type inversion in irradiated silicon: a half truth

Charge collection measurements performed on heavily irradiated p-spray dofz pixel sensors with a grazing angle hadron beam provide a sensitive determination of the electric field within the detectors. The data are compared with a complete charge transport simulation of the sensor which includes signal trapping and charge induction effects. A linearly varying electric field based upon the standard picture of a constant type-inverted effective doping density is inconsistent with the data. A two-trap double junction model implemented in ISE TCAD software can be tuned to produce a doubly-peaked electric field which describes the data reasonably well at two different fluences. The modeled field differs somewhat from previous determinations based upon the transient current technique. The model can also account for the level of signal trapping observed in the data.

physics.ins-det↗