SearcharxivSearch

arXiv subjects

C. Reyes

Publications and source records attributed to C. Reyes.

13 recordsLinked to original sources

Construction, commissioning, and beam test of a pilot 3D-projection opaque water-based liquid scintillator detector

We report on the design, construction, and beam test of a pilot three-dimensional projection detector based on opaque water-based liquid scintillator (oWbLS). The detector consists of an $8 \times 8 \times 16$ cm$^3$ acrylic vessel instrumented with three orthogonal planes of Kuraray Y11 multi-clad wavelength-shifting fibers read out by Hamamatsu multi-pixel photon counters. The readout electronics are based on the CITIROC front-end boards developed for the WAGASCI and SuperFGD detectors of the T2K experiment. The detector was filled with oWbLS and tested with cosmic rays and proton beams of 50, 100, 250, and 500 MeV kinetic energy at the NASA Space Radiation Laboratory at Brookhaven National Laboratory. We present three-dimensional event displays of cosmic muon and proton beam candidates, and a study of transverse light confinement via radial charge distribution measurements. The measured data show tighter light confinement than a Geant4 simulation with a 2 cm scattering length, placing the effective scattering length well below 2 cm and confirming effective optical confinement of scintillation light in the oWbLS medium. A first measurement of the hit-level timing resolution using 500 MeV proton beam data yields a single-channel timing resolution of $\sigma_t \approx 0.17$--$0.28$ ns with good photostatistics. These results demonstrate the viability of the 3D-projection oWbLS technology as a scalable, fully-active detector concept for next-generation particle physics experiments.

physics.ins-det

Design, construction, and operation of a 30-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based Liquid Scintillator (WbLS) was proposed over a decade ago as a novel detector medium that might allow the separation and tuning of the relative ratio of the Cherenkov and scintillation signals. A detector employing this technology could support large-scale neutrino detection over both the GeV and MeV energy regimes, while its metal-loading capability could provide an effective means of neutron tagging. WbLS is attractive for two reasons. It can be deployed in very large detectors. It also allows in-situ tuning of the scintillator concentration, and hence the ratio of Cherenkov to scintillation light. Neither pure water Cherenkov detectors nor conventional liquid scintillator detectors offer this capability. At Brookhaven National Laboratory (BNL), two prototypes have been built for understanding WbLS properties and stability, with masses of 1-ton and 30-ton, respectively. We present here the 30-ton prototype detector design, installation, and initial operation including the real-time observation of a transient optical response during the staged scintillator injection. Results from the analysis of data collected in the two detectors will follow in separate publications.

physics.ins-det

Measurement of Light Yield Response of Gd-compatible Water-based Liquid Scintillator with the Brookhaven 1-ton testbed

The Water-based Liquid Scintillator (WbLS) enables hybrid detection by combining scintillation and Cherenkov signals, providing superior event reconstruction capabilities compared to conventional neutrino detectors. We measured the light yield of Gd-compatible WbLS at varying concentrations from 0.35\% to 1\% by mass, using cosmic-ray muons in a 1-ton scale detector at BNL. The light yield is measured as (69.16 $\pm$ 6.92) ph / MeV at 0.35\% concentration, which increased to (87.32 $\pm$ 8.73) ph / MeV at 1\%. These results establish a quantitative basis for optimizing future WbLS-based detectors in neutrino physics.

physics.ins-det

First Light from Beam Neutrinos on an LAPPD in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is both a physics experiment and a technology testbed for next-generation light-based neutrino detection. In this paper, we report the first demonstration of a fully integrated Large Area Picosecond Photodetector (LAPPD) operating in a running neutrino beam experiment. Particular focus is given to the design, commissioning, and successful deployment of the Packaged ANNIE LAPPD (PAL), a waterproof, self-triggering module incorporating fast waveform digitization and precision timing synchronized to the ANNIE detector subsystems. We identify beam-correlated LAPPD data frames consistent with charged-current neutrino interactions observed in multiple detector subsystems, establishing the first detection of neutrino-induced Cherenkov light with an LAPPD. These results validate the system-level performance of LAPPDs under realistic experimental conditions-including long-term stability, timing synchronization, and event matching with conventional PMT and muon detector systems-marking a critical step toward their deployment in future large-scale neutrino and particle detectors.

hep-ex

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are attractive neutrino detector materials because they allow us to tune the ratio of the Cherenkov and scintillation signals. Using WbLS large-scale neutrino experiments can benefit from both directional reconstruction and enhanced low-energy efficiency. Furthermore, broadening the science capability of such materials by metal doping may be better suited for water based liquid scintillators. We recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early analysis results.

physics.ins-det

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is placed on the research and development of new detector technologies and target media. Specifically water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of scintillation and Cherenkov light. This paper presents the deployment of a 366L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. This proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses, such as the search for neutral current events and the hadronic scintillation component within the WbLS volume.

hep-ex

Measuring the CMB primordial B-modes with Bolometric Interferometry

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of Δν/ν \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.

astro-ph.CO

Status of QUBIC, the Q&U Bolometer for Cosmology

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematics with those of bolometric detectors in terms of wide-band, background-limited sensitivity.

astro-ph.IM

Performance characterization and near-realtime monitoring of MUSE adaptive optics modes at Paranal

The Multi Unit Spectroscopic Explorer (MUSE) is an integral field spectrograph on the Very Large Telescope Unit Telescope 4, capable of laser guide star assisted and tomographic adaptive optics using the GALACSI module. Its observing capabilities include a wide field (1 square arcmin), ground layer AO mode (WFM-AO) and a narrow field (7.5"x7.5"), laser tomography AO mode (NFM-AO). The latter has had several upgrades in the 4 years since commissioning, including an optimisation of the control matrices for the AO system and a new sub-electron noise detector for its infra-red low order wavefront sensor. We set out to quantify the NFM-AO system performance by analysing $\sim$230 spectrophotometric standard star observations taken over the last 3 years. To this end we expand upon previous work, designed to facilitate analysis of the WFM-AO system performance. We briefly describe the framework that will provide a user friendly, semi-automated way for system performance monitoring during science operations. We provide the results of our performance analysis, chiefly through the measured Strehl ratio and full width at half maximum (FWHM) of the core of the point spread function (PSF) using two PSF models, and correlations with atmospheric conditions. These results will feed into a range of applications, including providing a more accurate prediction of the system performance as implemented in the exposure time calculator, and the associated optimization of the scientific output for a given set of limiting atmospheric conditions.

astro-ph.IM

Hubble Space Telescope non-detection of PSR J2144-3933: the coldest known neutron star

We report non-detections of the $\sim 3\times 10^8$ yr old, slow, isolated, rotation-powered pulsar PSR J2144$-$3933 in observations with the Hubble Space Telescope in one optical band (F475X) and two far-ultraviolet bands (F125LP and F140LP), yielding upper bounds $F_{\rm F475X}< 22.7$ nJy, $F_{\rm F125LP}< 5.9$ nJy, $F_{\rm F140LP}< 19.5$ nJy, at the pivot wavelengths 4940 Å, 1438 Å and 1528 Å, respectively. Assuming a blackbody spectrum, we deduce a conservative upper bound on the surface (unredshifted) temperature of the pulsar of $T<42,000$ K. This makes PSR~J2144--3933 the coldest known neutron star, allowing us to study thermal evolution models of old neutron stars. This temperature is consistent with models with either direct or modified Urca reactions including rotochemical heating, and, considering frictional heating from the motion of neutron vortex lines, it puts an upper bound on the excess angular momentum in the neutron superfluid, $J<10^{44}\,\mathrm{erg\,s}$.

astro-ph.HE

Performance of the extreme-AO instrument VLT/SPHERE and dependence on the atmospheric conditions

SPHERE is the high-contrast exoplanet imager and spectrograph installed at the Unit Telescope 3 of the Very Large Telescope. After more than two years of regular operations, we analyse statistically the performance of the adaptive optics system and its dependence on the atmospheric conditions above the Paranal observatory, as measured by the suite of dedicated instruments which are part of the Astronomical Site Monitor and as estimated by the SPHERE real-time calculator. We also explain how this information can be used to schedule the observations in order to yield the best data quality and to guide the astronomer when processing his/her data.

astro-ph.IM

Old but still warm: Far-UV detection of PSR B0950+08

We report on a Hubble Space Telescope detection of the nearby, old pulsar B0950+08 ($d\simeq 262$ pc, spin-down age 17.5 Myr) in two far-ultraviolet (FUV) bands. We measured the mean flux densities $\bar{f}_ν= 109\pm 6$ nJy and $83\pm 14$ nJy in the F125LP and F140LP filters (pivot wavelengths 1438 and 1528 Å). Using the FUV data together with previously obtained optical-UV data, we conclude that the optical-FUV spectrum consists of two components -- a nonthermal (presumably magnetospheric) power-law spectrum ($f_ν\propto ν^α$) with slope $α\sim -1.2$ and a thermal spectrum emitted from the bulk of the neutron star surface with a temperature in the range of $(1-3)\times 10^5$ K, depending on interstellar extinction and neutron star radius. These temperatures are much higher than predicted by neutron star cooling models for such an old pulsar, which means that some heating mechanisms operate in neutron stars. A plausible mechanism responsible for the high temperature of PSR B0950+08 is the interaction of vortex lines of the faster rotating neutron superfluid with the slower rotating normal matter in the inner neutron star crust (vortex creep heating).

astro-ph.HE

Hubble Space Telescope detection of the millisecond pulsar J2124-3358 and its far-ultraviolet bow shock nebula

We observed a nearby millisecond pulsar J2124-3358 with the Hubble Space Telescope in broad far-UV (FUV) and optical filters. The pulsar is detected in both bands with fluxes F(1250-2000 A)= (2.5+/-0.3)x10^-16 erg/s/cm^2 and F(3800-6000 A)=(6.4+/-0.4)x10^-17 erg/s/cm^2, which correspond to luminosities of ~5.8x10^27 and 1.4x10^27 erg/s, for d=410 pc and E(B-V)=0.03. The optical-FUV spectrum can be described by a power-law model, f_nu~nu^alpha, with slope alpha=0.18-0.48 for a conservative range of color excess, E(B-V)=0.01-0.08. Since a spectral flux rising with frequency is unusual for pulsar magnetospheric emission in this frequency range, it is possible that the spectrum is predominantly magnetospheric (power law with alpha<0) in the optical while it is dominated by thermal emission from the neutron star surface in the FUV. For a neutron star radius of 12 km, the surface temperature would be between 0.5x10^5 and 2.1x10^5 K, for alpha ranging from -1 to 0, E(B-V)=0.01-0.08, and d=340-500 pc. In addition to the pulsar, the FUV images reveal extended emission spatially coincident with the known Halpha bow shock, making PSR J2124-3358 the second pulsar (after PSR J0437-4715) with a bow shock detected in FUV.

astro-ph.HE