SearcharxivSearch

arXiv subjects

C. S. Chiu

Publications and source records attributed to C. S. Chiu.

5 recordsLinked to original sources

Implementation of a stable, high-power optical lattice for quantum gas microscopy

We describe the design and implementation of a stable high-power 1064 nm laser system to generate optical lattices for experiments with ultracold quantum gases. The system is based on a low-noise laser amplified by an array of four heavily modified, high-power fiber amplifiers. The beam intensity is stabilized and controlled with a nonlinear feedback loop. Using real-time monitoring of the resulting optical lattice, we find the stability of the lattice site positions to be well below the lattice spacing over the course of hours. The position of the harmonic trap produced by the Gaussian envelope of the lattice beams is stable to about one lattice spacing and the long-term (six-month) relative RMS stability of the lattice spacing itself is 0.5%.

cond-mat.quant-gas

Design and Construction of the MicroBooNE Detector

This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.

physics.ins-det

Low-noise optical lattices for ultracold $^6$Li

We demonstrate stable, long-term trapping of fermionic $^6$Li atoms in an optical lattice with MHz trap frequencies for use in a quantum gas microscope. Adiabatic release from the optical lattice in the object plane of a high-numerical-aperture imaging system allows a measurement of the population distribution among the lowest three bands in both radial directions with atom numbers as low as $7\times 10^2$. We measure exponential ground band heating rates as low as 0.014(1) s$^{-1}$ corresponding to a radial ground state $1/e$ lifetime of 71(5) s, fundamentally limited by scattering of lattice photons. For all lattice depths above 2 recoil, we find radial ground state lifetimes $\ge 1.6 \times 10^6$ recoil times.

physics.atom-ph

A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of $(1.51\pm 0.15)\times10^{-4} \;\mathrm{cm^{-1} ppm^{-1}}$, corresponding to an absorption cross section of $(7.14 \pm 0.74)\times10^{-21}\;\mathrm{cm^{2} molecule^{-1}}$. We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be $30 \pm 3$ meters.

physics.ins-det

Environmental Effects on TPB Wavelength-Shifting Coatings

The scintillation detection systems of liquid argon time projection chambers (LArTPCs) require wavelength shifters to detect the 128 nm scintillation light produced in liquid argon. Tetraphenyl butadiene (TPB) is a fluorescent material that can shift this light to a wavelength of 425 nm, lending itself well to use in these detectors. We can coat the glass of photomultiplier tubes (PMTs) with TPB or place TPB-coated plates in front of the PMTs. In this paper, we investigate the degradation of a chemical TPB coating in a laboratory or factory environment to assess the viability of long-term TPB film storage prior to its initial installation in an LArTPC. We present evidence for severe degradation due to common fluorescent lights and ambient sunlight in laboratories, with potential losses at the 40% level in the first day and eventual losses at the 80% level after a month of exposure. We determine the degradation is due to wavelengths in the UV spectrum, and we demonstrate mitigating methods for retrofitting lab and factory environments.

physics.ins-det