SearcharxivSearch

arXiv subjects

C. So

Publications and source records attributed to C. So.

11 recordsLinked to original sources

Simulation of STIRAP from the 1S to the 2S states of the Hydrogen/Antihydrogen atoms

Achieving a high population of antihydrogen/hydrogen atoms in the 2S level is essential for spectroscopy measurements testing similarities between matter and antimatter. We propose and examine the efficiency of applying the STIRAP (Stimulated Raman Adiabatic Passage) process in achieving high population transfer from the 1S to the 2S levels. We utilized a circularly polarized Lyman alpha, Ly-$\alpha$, pulse to couple the 1S state to the 2P state and a microwave pulse to couple the 2P state and the 2S state. We calculate the efficiency of the STIRAP process for transferring the population between the stretched states $(1S_d, 2S_d)$ as a function of experimental parameters such as Rabi frequencies and pulse durations. We find that a Ly-$\alpha$ pulse with an energy of a few nanojoules could produce nearly perfect transfer at zero detunings for atoms on the laser beam axis. We extended the analysis to a thermal ensemble of atoms, where Doppler detuning affects the velocity distribution of the hydrogen atoms produced in the 2S level. We found that the width of such velocity distribution is controlled by the Rabi frequency. We show that the peak velocity of the hydrogen atoms in the 2S level after STIRAP can be controlled by the Ly-$\alpha$ pulse detuning. The efficiency of STIRAP in transferring population increases at low temperature (T$\sim$1~mK). Finally, we show that a background magnetic field improves the transfer rates between the other trappable states $(1S_c, 2S_c)$.

physics.atom-ph

Design and Performance of a Novel Low Energy Multi-Species Beamline for the ALPHA Antihydrogen Experiment

The ALPHA Collaboration, based at the CERN Antiproton Decelerator, has recently implemented a novel beamline for low-energy ($\lesssim$ 100 eV) positron and antiproton transport between cylindrical Penning traps that have strong axial magnetic fields. Here, we describe how a combination of semianalytical and numerical calculations were used to optimise the layout and design of this beamline. Using experimental measurements taken during the initial commissioning of the instrument, we evaluate its performance and validate the models used for its development. By combining data from a range of sources, we show that the beamline has a high transfer efficiency, and estimate that the percentage of particles captured in the experiments from each bunch is (78 $\pm$ 3)% for up to $10^{5}$ antiprotons, and (71 $\pm$ 5)% for bunches of up to $10^{7}$ positrons.

physics.acc-ph

Limit on the Electric Charge of Antihydrogen

The ALPHA collaboration has successfully demonstrated the production and the confinement of cold antihydrogen, $\overline{\mathrm{H}}$. An analysis of trapping data allowed a stringent limit to be placed on the electric charge of the simplest antiatom. Charge neutrality of matter is known to a very high precision, hence a neutrality limit of $\overline{\mathrm{H}}$ provides a test of CPT invariance. The experimental technique is based on the measurement of the deflection of putatively charged $\overline{\mathrm{H}}$ in an electric field. The tendency for trapped $\overline{\mathrm{H}}$ atoms to be displaced by electrostatic fields is measured and compared to the results of a detailed simulation of $\overline{\mathrm{H}}$ dynamics in the trap. An extensive survey of the systematic errors is performed, with particular attention to those due to the silicon vertex detector, which is the device used to determine the $\overline{\mathrm{H}}$ annihilation position. The limit obtained on the charge of the $\overline{\mathrm{H}}$ atom is \mbox{$ Q = (-1.3\pm1.8\pm0.4)\times10^{-8}$}, representing the first precision measurement with $\overline{\mathrm{H}}$.

physics.atom-ph

Plasma Temperature Measurement with a Silicon Photomultiplier (SiPM)

The temperature of a nonneutral plasma confined in a Penning-Malmberg trap can be determined by slowly lowering one side of the trap's electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. Often, the escaping particles are directed toward a microchannel plate (MCP), and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma, but can also be used as a Faraday cup FC for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen's high voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focusses on the advantages of a SiPM over a FC.

physics.ins-det

Electron Plasmas Cooled by Cyclotron-Cavity Resonance

We observe that high-Q electromagnetic cavity resonances increase the cyclotron cooling rate of pure electron plasmas held in a Penning-Malmberg trap when the electron cyclotron frequency, controlled by tuning the magnetic field, matches the frequency of standing wave modes in the cavity. For certain modes and trapping configurations, this can increase the cooling rate by factors of ten or more. In this paper, we investigate the variation of the cooling rate and equilibrium plasma temperatures over a wide range of parameters, including the plasma density, plasma position, electron number, and magnetic field.

physics.plasm-ph

In situ electromagnetic field diagnostics with an electron plasma in a Penning-Malmberg trap

We demonstrate a novel detection method for the cyclotron resonance frequency of an electron plasma in a Penning-Malmberg trap. With this technique, the electron plasma is used as an in situ diagnostic tool for measurement of the static magnetic field and the microwave electric field in the trap. The cyclotron motion of the electron plasma is excited by microwave radiation and the temperature change of the plasma is measured non-destructively by monitoring the plasma's quadrupole mode frequency. The spatially-resolved microwave electric field strength can be inferred from the plasma temperature change and the magnetic field is found through the cyclotron resonance frequency. These measurements were used extensively in the recently reported demonstration of resonant quantum interactions with antihydrogen.

physics.plasm-ph

Antihydrogen and mirror-trapped antiproton discrimination: Discriminating between antihydrogen and mirror-trapped antiprotons in a minimum-B trap

Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the magnetic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and antiprotons in the antiatoms annihilated. The antiproton annihilations produce easily detected signals; we used these signals to prove that we trapped antihydrogen. However, our technique could be confounded by mirror-trapped antiprotons, which would produce seemingly-identical annihilation signals upon hitting the trap wall. In this paper, we discuss possible sources of mirror-trapped antiprotons and show that antihydrogen and antiprotons can be readily distinguished, often with the aid of applied electric fields, by analyzing the annihilation locations and times. We further discuss the general properties of antiproton and antihydrogen trajectories in this magnetic geometry, and reconstruct the antihydrogen energy distribution from the measured annihilation time history.

physics.atom-ph

Confinement of antihydrogen for 1000 seconds

Atoms made of a particle and an antiparticle are unstable, usually surviving less than a microsecond. Antihydrogen, made entirely of antiparticles, is believed to be stable, and it is this longevity that holds the promise of precision studies of matter-antimatter symmetry. We have recently demonstrated trapping of antihydrogen atoms by releasing them after a confinement time of 172 ms. A critical question for future studies is: how long can anti-atoms be trapped? Here we report the observation of anti-atom confinement for 1000 s, extending our earlier results by nearly four orders of magnitude. Our calculations indicate that most of the trapped anti-atoms reach the ground state. Further, we report the first measurement of the energy distribution of trapped antihydrogen which, coupled with detailed comparisons with simulations, provides a key tool for the systematic investigation of trapping dynamics. These advances open up a range of experimental possibilities, including precision studies of CPT symmetry and cooling to temperatures where gravitational effects could become apparent.

physics.atom-ph

Centrifugal separation and equilibration dynamics in an electron-antiproton plasma

Charges in cold, multiple-species, non-neutral plasmas separate radially by mass, forming centrifugally-separated states. Here, we report the first detailed measurements of such states in an electron-antiproton plasma, and the first observations of the separation dynamics in any centrifugally-separated system. While the observed equilibrium states are expected and in agreement with theory, the equilibration time is approximately constant over a wide range of parameters, a surprising and as yet unexplained result. Electron-antiproton plasmas play a crucial role in antihydrogen trapping experiments.

physics.plasm-ph

Alpha Antihydrogen Experiment

ALPHA is an experiment at CERN, whose ultimate goal is to perform a precise test of CPT symmetry with trapped antihydrogen atoms. After reviewing the motivations, we discuss our recent progress toward the initial goal of stable trapping of antihydrogen, with some emphasis on particle detection techniques.

nucl-ex

Evaporative Cooling of Antiprotons to Cryogenic Temperatures

We report the application of evaporative cooling to clouds of trapped antiprotons, resulting in plasmas with measured temperature as low as 9~K. We have modeled the evaporation process for charged particles using appropriate rate equations. Good agreement between experiment and theory is observed, permitting prediction of cooling efficiency in future experiments. The technique opens up new possibilities for cooling of trapped ions and is of particular interest in antiproton physics, where a precise \emph{CPT} test on trapped antihydrogen is a long-standing goal.

physics.plasm-ph