SearcharxivSearch

arXiv subjects

C. Voena

Publications and source records attributed to C. Voena.

At least 19 recordsLinked to original sources

The Use of O2 in Gas Mixtures for Drift Chambers

The use of Oxygen in gas mixtures for drift chambers is highly discouraged because Oxygen, being strongly electronegative, is generally believed to lead, even in very small quantities, to extremely reduced drift electron survival probability, thus preventing the detector's operation.The drift chamber of the MEG II experiment at PSI has been operating for several years with a gas mixture that mainly contains He:Isobutane in relative proportions of 90:10% by molar concentration, in addition to 1.5% Isopropanol and 0.5% Oxygen. Oxygen and Isopropanol are essential for the proper functioning of the chamber. The electron attachment in the mixture used has proven negligible for the proper operation of the chamber and agrees well with the Garfield++ simulation after correctly accounting for the three-body attachment simulation.

physics.ins-det

New limit on the \mu+->e+\gamma decay with the MEG II experiment

This letter reports the result of the search for the decay \mu+->e+\gamma undertaken at the Paul Scherrer Institut in Switzerland with the MEG II experiment using the data collected in the 2021- 2022 physics runs. The sensitivity of this search is 2.2x10-13, a factor of 2.4 better than that of the full MEG dataset and obtained in a data taking period of about one fourth that of MEG, thanks to the superior performances of the new detector. The result is consistent with the expected background, yielding an upper limit on the branching ratio of B(\mu+->e+\gamma)<1.5 x 10-13 (90 % C.L.). Additional improvements are expected with the data collected during the years 2023-2024. The data-taking will continue in the coming years.

hep-ex

A compact frozen-spin trap for the search for the electric dipole moment of the muon

The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, \$E \approx 165\$ MV/m, experienced in the rest frame of the muon with a momentum of about 23 MeV/c when it passes through a solenoidal magnetic field of \$|\vec{B}|=2.5\$ T. In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase~I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is 4E-21 ecm. In a subsequent phase, Phase~II, we propose to improve the sensitivity to 6E-23 ecm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 MeV/c}.

hep-ex

Search for the X17 particle in $^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^{-}) ^{8}\mathrm{Be}$ processes with the MEG II detector

The observation of a resonance structure in the opening angle of the electron-positron pairs in the $^{7}$Li(p,\ee) $^{8}$Be reaction was claimed and interpreted as the production and subsequent decay of a hypothetical particle (X17). Similar excesses, consistent with this particle, were later observed in processes involving $^{4}$He and $^{12}$C nuclei with the same experimental technique. The MEG II apparatus at PSI, designed to search for the $\mu^+ \rightarrow \mathrm{e}^+ \gamma$ decay, can be exploited to investigate the existence of this particle and study its nature. Protons from a Cockroft-Walton accelerator, with an energy up to 1.1 MeV, were delivered on a dedicated Li-based target. The $\gamma$ and the e$^{+}$e$^{-}$ pair emerging from the $^8\mathrm{Be}^*$ transitions were studied with calorimeters and a spectrometer, featuring a broader angular acceptance than previous experiments. We present in this paper the analysis of a four-week data-taking in 2023 with a beam energy of 1080 keV, resulting in the excitation of two different resonances with Q-value \SI{17.6}{\mega\electronvolt} and \SI{18.1}{\mega\electronvolt}. No significant signal was found, and limits at \SI{90}{\percent} C.L. on the branching ratios (relative to the $\gamma$ emission) of the two resonances to X17 were set, $R_{17.6} < 1.8 \times 10^{-6} $ and $R_{18.1} < 1.2 \times 10^{-5} $.

nucl-ex

A search for $\mu^+\to e^+\gamma$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $\mu^+\to e^+\gamma$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($\mu^+\to e^+\gamma$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($\mu^+\to e^+\gamma$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

hep-ex

Performances of a new generation tracking detector: the MEG II cylindrical drfit chamber

The cylindrical drift chamber is the most innovative part of the MEG~II detector, the upgraded version of the MEG experiment. The MEG~II chamber differs from the MEG one because it is a single volume cylindrical structure, instead of a segmented one, chosen to improve its resolutions and efficiency in detecting low energy positrons from muon decays at rest. In this paper, we show the characteristics and performances of this fundamental part of the MEG~II apparatus and we discuss the impact of its higher resolution and efficiency on the sensitivity of the MEG~II experiment. Because of its innovative structure and high quality resolution and efficiency the MEG~II cylindrical drift chamber will be a cornerstone in the development of an ideal tracking detector for future positron-electron collider machines.

physics.ins-det

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

physics.ins-det

Operating the GridPix detector with helium-isobutane gas mixtures for a high-precision, low-mass Time Projection Chamber

High precision experiments with muons and pions often require tracking charged particles with $O(100~\mu\mathrm{m})$ single-hit resolution, possibly with particle identification capabilities, down to very low momenta ($p \lesssim 100$~MeV/$c$). In such conditions, the particle trajectories are strongly affected by the interaction with the detector material, and the reconstruction of the kinematic observables consequently deteriorates. A good compromise between resolution and material budget can be obtained with a Time Projection Chamber (TPC), if very light gases and a high-granularity readout are used. In this paper, we present a characterization of the GridPix detector in helium-isobutane gas mixtures, within a TPC with 9~cm maximum drift. Measurements of the main electron drift properties for these gas mixtures are also presented.

physics.ins-det

The measuring systems of the wire tension for the MEG II Drift Chamber by means of the resonant frequency technique

The ultra-low mass cylindrical drift chamber designed for the MEG II experiment is a challenging apparatus made of 1728 phi = 20 micron gold plated tungsten sense wires, 7680 phi = 40 micron and 2496 phi = 50 micron silver plated aluminum field wires. Because of electrostatic stability requirements all the wires have to be stretched at mechanical tensions of about 25, 19 and 29 g respectively which must be controlled at a level better than 0.5 g. This chamber is presently in acquisition, but during its construction about 100 field wires broke, because of chemical corrosion induced by the atmospheric humidity. On the basis of the experience gained with this chamber we decided to build a new one, equipped with a different type of wires less sensitive to corrosion. The choice of the new wire required a deep inspection of its characteristics and one of the main tools for doing this is a system for measuring the wire tension by means of the resonant frequency technique, which is described in this paper. The system forces the wires to oscillate by applying a sinusoidal signal at a known frequency, and then measures the variation of the capacitance between a wire and a common ground plane as a function of the external signal frequency. We present the details of the measuring system and the results obtained by scanning the mechanical tensions of two samples of MEG II cylindrical drift chamber wires and discuss the possible improvements of the experimental apparatus and of the measuring technique.

physics.ins-det

Detailed analysis of chemical corrosion of ultra-thin wires used in drift chamber detectors

Ultra-thin metallic anodic and cathodic wires are frequently employed in low-mass gaseous detectors for precision experiments, where the amount of material crossed by charged particles must be minimised. We present here the results of an analysis of the mechanical stress and chemical corrosion effects observed in $40$ and $50~{\rm{\mu m}}$ diameter silver plated aluminum wires mounted within the volume of the MEG\,II drift chamber, which caused the breaking of about one hundred wires (over a total of $\approx 12000$). This analysis is based on the accurate inspection of the broken wires by means of optical and electronic microscopes and on a detailed recording of all breaking accidents. We present a simple empirical model which relates the number of broken wires to their exposure time to atmospheric humidity and to their mechanical tension, which is necessary for mechanical stability in the presence of electrostatic fields of several kV/cm. Finally we discuss how wire breakings can be avoided or at least strongly reduced by operating in controlled atmosphere during the mounting stages of the wires within the drift chamber and by choosing a $25\,\%$ thicker wire diameter, which has very small effects on the detector resolution and efficiency and can be obtained by using a safer fabrication technique.

physics.ins-det

Search for a muon EDM using the frozen-spin technique

This letter of intent proposes an experiment to search for an electric dipole moment of the muon based on the frozen-spin technique. We intend to exploit the high electric field, $E=1{\rm GV/m}$, experienced in the rest frame of the muon with a momentum of $p=125 {\rm MeV/}c$ when passing through a large magnetic field of $|\vec{B}|=3{\rm T}$. Current muon fluxes at the $\mu$E1 beam line permit an improved search with a sensitivity of $\sigma(d_\mu)\leq 6\times10^{-23}e{\rm cm}$, about three orders of magnitude more sensitivity than for the current upper limit of $|d_\mu|\leq1.8\times10^{-19}e{\rm cm}$\,(C.L. 95\%). With the advent of the new high intensity muon beam, HIMB, and the cold muon source, muCool, at PSI the sensitivity of the search could be further improved by tailoring a re-acceleration scheme to match the experiments injection phase space. While a null result would set a significantly improved upper limit on an otherwise un-constrained Wilson coefficient, the discovery of a muon EDM would corroborate the existence of physics beyond the Standard Model.

hep-ex

A photogrammetric method for target monitoring inside the MEG II detector

An automatic target monitoring method based on photographs taken by a CMOS photo-camera has been developed for the MEG II detector. The technique could be adapted for other fixed-target experiments requiring good knowledge of their target position to avoid biases and systematic errors in measuring the trajectories of the outcoming particles. A CMOS-based, high resolution, high radiation tolerant and high magnetic field resistant photo-camera was mounted inside the MEG II detector at the Paul Scherrer Institute (Switzerland). MEG II is used to search for lepton flavour violation in muon decays. The photogrammetric method's challenges, affecting measurements of low momentum particles' tracks, are high magnetic field of the spectrometer, high radiation levels, tight space constraints, and the need to limit the material budget in the tracking volume. The camera is focused on dot pattern drawn on the thin MEG II target, about 1 m away from the detector endcaps where the photo-camera is placed. Target movements and deformations are monitored by comparing images of the dots taken at various times during the measurement. The images are acquired with a Raspberry board and analyzed using a custom software. Global alignment to the spectrometer is guaranteed by corner cubes placed on the target support. As a result, the target monitoring fulfils the needs of the experiment.

physics.ins-det

The Drift Chamber of the MEG II experiment

The MEG experiment at the Paul Scherrer Institut searches for the charged-Lepton-Flavor-Violating mu+ -> e+ gamma decay. MEG has already set the world best upper limit on the branching ratio: BR<4.2x10^-13 @ 90% C.l. An upgrade (MEG II) of the whole detector has been approved to obtain a substantial increase of sensitivity. Currently MEG II is completing the upgrade of the various detectors, an engineering run and a pre-commissioning run were carried out during 2018 and 2019. The new positron tracker is a unique volume, ultra-light He based cylindrical drift chamber (CDCH), with high granularity: 9 layers of 192 square drift cells, ~6-9 mm wide, consist of ~12000 wires in a full stereo configuration. To ensure the electrostatic stability of the drift cells a new wiring strategy should be developed due to the high wire density (12 wires/cm^2 ), the stringent precision requirements on the wire position and uniformity of the wire mechanical tension (better than 0.5 g) The basic idea is to create multiwire frames, by soldering a set of (16 or 32) wires on 40 um thick custom wire-PCBs. Multiwire frames and PEEK spacers are overlapped alternately along the radius, to set the proper cell width, in each of the twelve sectors defined by the spokes of the rudder wheel shaped end-plates. Despite to the conceptual simplicity of the assembling strategies, the building of the multiwire frames, with the set requirements, imposes a use of an automatic wiring system. The MEG II CDCH is the first cylindrical drift chamber ever designed and built in a modular way and it will allow to track positrons, with a momentum greater than 45 MeV/c, with high efficiency by using a very small amount of material, 1.5x10^-3 X0 . We describe the CDCH design and construction, the wiring phase at INFN-Lecce, the choice of the wires, their mechanical properties, the assembly and sealing at INFN-Pisa and the commissioning.

physics.ins-det

Performance of an optically read out time projection chamber with ultra-relativistic electrons

The Time Projection Chamber (TPC) is an ideal candidate to finely study the charged particle ionization in a gaseous medium. Large volumes TPCs can be read out with a suitable number of channels offering a complete 3D reconstruction of an ultra-relativistic charged particle track, that is the sequence of its energy releases in the TPC gas volume. Moreover, He-based TPCs are very promising to study keV energy particles as nuclear recoils, opening the possibility for directional searches of Dark Matter (DM) and the study of Solar Neutrinos (SN). In this paper, we report the analysis of the data acquired with a small TPC prototype (named LEMOn) built by the CYGNO collaboration that was exposed to a beam of 450 MeV electrons at the Beam Test Facility of National Laboratories of Frascati. LEMOn is operated with a He-CF4 mixture at atmospheric pressure and is based on a Gas Electron Multipliers amplification stage that produces visible light collected by a sub-millimeter position resolution scientific CMOS camera. This type of readout - in conjunction with a fast light detection - allows a 3D reconstruction of the electrons' tracks. The electrons are leaving a trail of segments of ionizations corresponding to a few keV energy releases each. Their study leads to predict a keV energy threshold and 1-10 mm longitudinal and 0.1-0.3 mm transverse position resolution for nuclear recoils, very promising for the application of optically readout TPC to DM searches and SN measurements.

physics.ins-det

The new drift chamber of the MEG II experiment

This article presents the MEG II Cylindrical Drift CHamber (CDCH), a key detector for the phase 2 of MEG, which aims at reaching a sensitivity level of the order of $6 \times 10^{-14}$ for the charged Lepton Flavour Violating $\mu^+ \rightarrow \mbox{e}^+ \gamma$ decay. CDCH is designed to overcome the limitations of the MEG $\mbox{e}^+$ tracker and guarantee the proper operation at high rates with long-term detector stability. CDCH is a low-mass unique volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by $\approx 12000$ wires in a stereo configuration for longitudinal hit localization. The total radiation length is $1.5 \times 10^{-3}$ $\mbox{X}_0$, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution of 110 $\mu$m and a momentum resolution of 130 keV/c. CDCH integration into the MEG II experimental apparatus will start in this year.

physics.ins-det

Commissioning of the MEG II tracker system

The MEG experiment at the Paul Scherrer Institut (PSI) represents the state of the art in the search for the charged Lepton Flavour Violating (cLFV) $\mu^+ \rightarrow e^+ \gamma$ decay. With the phase 1, MEG set the new world best upper limit on the $\mbox{BR}(\mu^+ \rightarrow e^+ \gamma) < 4.2 \times 10^{-13}$ (90% C.L.). With the phase 2, MEG II, the experiment aims at reaching a sensitivity enhancement of about one order of magnitude compared to the previous MEG result. The new Cylindrical Drift CHamber (CDCH) is a key detector for MEG II. CDCH is a low-mass single volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by $\sim 12000$ wires in a stereo configuration for longitudinal hit localization. The filling gas mixture is Helium:Isobutane (90:10). The total radiation length is $1.5 \times 10^{-3}$ $\mbox{X}_0$, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution $< 120$ $\mu$m and an angular and momentum resolutions of 6 mrad and 90 keV/c respectively. This article presents the CDCH commissioning activities at PSI after the wiring phase at INFN Lecce and the assembly phase at INFN Pisa. The endcaps preparation, HV tests and conditioning of the chamber are described, aiming at reaching the final stable working point. The integration into the MEG II experimental apparatus is described, in view of the first data taking with cosmic rays and $\mu^+$ beam during the 2018 and 2019 engineering runs. The first gas gain results are also shown. A full engineering run with all the upgraded detectors and the complete DAQ electronics is expected to start in 2020, followed by three years of physics data taking.

physics.ins-det

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $\mu^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to \gamma\gamma$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.

hep-ex

Gas Distribution and Monitoring for the Drift Chamber of the MEG-II Experiment

The reconstruction of the positron trajectory in the MEG-II experiment searching for the $\mu^+ \to e^+ \gamma$ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitored. In this paper we describe the strategies adopted to meet the requirements imposed by the target sensitivity of MEG-II, including the construction and commissioning of a small chamber for an online monitoring of the gas quality.

physics.ins-det