SearcharxivSearch

arXiv subjects

C. Weinheimer

Publications and source records attributed to C. Weinheimer.

At least 19 recordsLinked to original sources

HERETIX: A Hermetic, Enriched, Rare-Event Time Projection Chamber in Xenon

Xenon-based time projection chambers have established themselves as one of the most powerful technologies for rare-event searches. HERETIX is a proposed multi-tonne liquid xenon observatory featuring two nested time projection chambers that enable the simultaneous optimisation of searches for weakly interacting massive particles and neutrinoless double beta decay ($0\nu\beta\beta$) of $^{136}$Xe. A hermetically sealed sapphire vessel containing xenon enriched to 90% $^{136}$Xe forms the inner detector, providing an ultra-low-background environment for $0\nu\beta\beta$ searches. Monte Carlo studies indicate that material-induced backgrounds can be effectively eliminated, yielding a projected $0\nu\beta\beta$ half-life sensitivity of $3.2 \times 10^{28} \, \mathrm{years}$ at 90% confidence level after a 10-year exposure, while the surrounding xenon volume, depleted in $^{136}$Xe, preserves the excellent dark matter sensitivity of large liquid xenon detectors. HERETIX therefore offers a unified experimental approach capable of delivering leading sensitivity to two of the most compelling questions in fundamental physics.

physics.ins-det

Proof-of-concept of a xenon-based cryogenic heat pump demonstrator for future liquid xenon observatories

This manuscript details the proof-of-concept of a small-scale cryogenic heat pump demonstrator, a technology designed to enable high-flow xenon distillation systems for the removal of $^{222}$Rn in future liquid xenon observatories such as the XLZD experiment. The heat pump demonstrator operates on a left-turning Clausius-Rankine cycle, utilizing xenon as a phase-changing working medium. The design aims to fully hermetically separate the heat pump from the radon removal system, simplifying material cleanliness and maintenance compared to currently operating systems. Two demonstration tests were conducted at nominal pressures of $3.3\,\mathrm{bar}$ and $4.3\,\mathrm{bar}$, utilizing a cold head and electrical heaters to mimic the behavior of a xenon distillation system. In both measurements, the demonstrator achieved a cooling and heating power of $(118\pm3)\,\mathrm{W}$ and $(121\pm3)\,\mathrm{W}$, respectively. This is sufficient to operate a small distillation system with a virtual purification mass flow of about $3.1\,\mathrm{kg/h}$, while consuming $386\pm1\,\mathrm{W}$ electrical power. Compered to currently operating applications using commercial cold heads driven by helium compressors, which typically require about $6\,\mathrm{kW}$ of electrical power, this is significantly lower. The presented proof-of-concept heat pump demonstrator is further put into perspective with the currently planned XLZD experiment using a simplified scaling model. This model indicates that a radon removal system with a purification mass flow of $1600\,\mathrm{kg/h}$ and a required cooling and heating power of about $60\,\mathrm{kW}$ each, will be sufficient to cover a variety of different detector masses and background conditions.

physics.ins-det

An active Transverse Energy Filter based on microstructured Si-PIN diodes with an angular-selective detection efficiency

Si-PIN detectors can be microstructured to achieve angular-selective particle detection capabilities, which we call active Transverse Energy Filter (aTEF). The microstructuring consists of a honeycomb structure of deep hexagonally-shaped holes with active silicon side walls, while the bottom of the holes is made insensitive to ionizing radiation. The motivation for this kind of detector arises from the need to distinguish background electrons from signal electrons in a spectrometer of MAC-E filter type. We have demonstrated the angular-dependent detection efficiency of self-fabricated aTEF prototypes in a test setup using an angular-selective photoelectron source to illuminate the detector from various incidence angles.

physics.ins-det

Testing strong-field QED to second-order in the highly correlated atomic system berylliumlike Pb78+ by electron-ion recombination spectroscopy

A low-energy storage ring with an ultracold electron cooler has been coupled with a heavy-ion accelerator facilitating high-resolution electron-ion collision spectroscopy of the heaviest few-electron ions. In the present work resonant electron-ion recombination of berylliumlike Pb$^{78+}$ ions was measured in the collision-energy range 9.3-16.5eV and a value of 244.937(30) eV is derived for the Pb$^{78+}$($2s^2\;^1S_0 - 2s\,2p\;^3P_1$) excitation energy. This result agrees with the most recent (less accurate) theoretical value of 244.942(52) eV [Malyshev et al., Physical Review A 110, 062824 (2024)], which has been calculated by applying strong-field QED rigorously up to the second order. The present investigation suggests that further technical improvements can potentially increase the experimental accuracy by an order of magnitude.

physics.atom-ph

A Setup to Study Atomic State Population Dynamics and Optical Polarization at CRYRING@ESR

We present a recently established setup for laser spectroscopy at CRYRING@ESR at the GSI Helmholtz Centre for Heavy Ion Research. Here, laser spectroscopy can be performed on stored and cooled ion bunches and coasting beams. First spectra of $^{24,25}$Mg$^+$ ions are presented that were recorded by classical Doppler-limited fluorescence spectroscopy as well as $\Lambda$-spectroscopy using counter- and copropagating laser beams that are Doppler-shifted by several nm.

physics.atom-ph

Improved treatment of the $T_2$ molecular final-states uncertainties for the KATRIN neutrino-mass measurement

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective mass of the electron antineutrino via a high-precision measurement of the tritium beta-decay spectrum in its end-point region. The target neutrino-mass sensitivity of 0.2 eV / c^2 at 90% C.L. can only be achieved in the case of high statistics and a good control of the systematic uncertainties. One key systematic effect originates from the calculation of the molecular final states of T_2 beta decay. In the first neutrino-mass analyses of KATRIN the contribution of the uncertainty of the molecular final-states distribution (FSD) was estimated via a conservative phenomenological approach to be 0.02 eV^2 / c^4. In this paper a new procedure is presented for estimating the FSD-related uncertainties by considering the details of the final-states calculation, i.e. the uncertainties of constants, parameters, and functions used in the calculation as well as its convergence itself as a function of the basis-set size used in expanding the molecular wave functions. The calculated uncertainties are directly propagated into the experimental observable, the squared neutrino mass m_nu^2. With the new procedure the FSD-related uncertainty is constrained to 0.0013 eV^2 / c^4, for the experimental conditions of the first KATRIN measurement campaign.

physics.data-an

Electro-purification studies and first measurement of relative permittivity of TMBi

A new type of detector for positron-emission tomography (PET) has been proposed recently, using a heavy organo-metallic liquid - TriMethyl Bismuth (TMBi) - as target material. TMBi is a transparent liquid with the high Z element Bismuth contributing 82% of its mass. 511keV annihilation photons are converted efficiently into photo-electrons within the detector material producing both Cherenkov light and free charge carriers in the liquid. While the optical component enables a fast timing, a charge readout using a segmented anode can provide an accurate position reconstruction and energy determination. The charge measurement requires a high level of purification, as any electronegative contaminants cause signal degradation. In addition to the purity requirements, the reactive nature of TMBi poses many challenges that need to be met until a fully functioning detector for PET applications can be realized. The paper presents an experimental setup that aims to remove electronegative impurities by electrostatic filtering and to characterise the properties of TMBi, e.g. the relative permittivity, for its application as a detector medium for charge read out.

physics.ins-det

An active transverse energy filter to differentiate low energy particles with large pitch angles in a strong magnetic field

We present the idea and proof of principle measurements for an angular-selective active filter for charged particles. The motivation for the setup arises from the need to distinguish background electrons from signal electrons in a spectrometer of MAC-E filter type. While a large fraction of the background electrons exhibit predominantly small angles relative to the magnetic guiding field (corresponding to a low amount of kinetic energy in the motion component transverse to the field lines, in the following referred to as transverse energy) and pass the filter mostly unhindered, signal electrons from an isotropically emitting source interact with the active filter and are detected. The concept is demonstrated using a microchannel plate (MCP) as an active filter element. When correctly aligned with the magnetic field, electrons with a small transverse energy pass the channels of the MCP without interaction while electrons with large transverse energies hit the channel walls and trigger an avalanche of secondary electrons that is subsequently detected. Due to several drawbacks of MCPs for an actual transverse energy filter, an alternative detection technique using microstructured Si-PIN diodes is proposed.

physics.ins-det

Design, construction and commissioning of a high-flow radon removal system for XENONnT

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT liquid xenon inventory of 8.4 tonnes at process flows up to 71 kg/h (200 slpm) is required to achieve a radon reduction by a factor two for radon sources inside the detector. To reach such high flows, the distillation column's design features liquid xenon inlet and outlets along with novel custom-made bath-type heat exchangers with high liquefaction capabilities. The distillation process was designed using a modification of the McCabe-Thiele approach without a bottom product extraction. The thermodynamic concept is based on a Clausius-Rankine cooling cycle with phase-changing medium, in this case the xenon itself. To drastically reduce the external cooling power requirements, an energy efficient heat pump concept was developed applying a custom-made four cylinder magnetically-coupled piston pump as compressor. The distillation system was operated at thermodynamically stable conditions at a process flow of (91$\pm$2) kg/h ((258$\pm$6) slpm), 30 % over design. With this flow, a $^{222}$Rn activity concentration <1 $μ$Bq/kg is expected inside the XENONnT detector given the measured radon source distribution.

physics.ins-det

Wideband precision stabilization of the -18.6 kV retarding voltage for the KATRIN spectrometer

The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV (90 % C.L.). In this experiment, the energy spectrum of beta electrons near the tritium decay endpoint is analyzed with a highly accurate spectrometer. To reach the KATRIN sensitivity target, the retarding voltage of this spectrometer must be stable to the ppm level and well known on various time scales ($μs$ up to months), for values around -18.6 kV. A custom-designed high-voltage regulation system mitigates the impact of interference sources in the absence of a closed electric shield around the large spectrometer vessel. In this article, we describe the regulation system and its integration into the KATRIN setup. Independent monitoring methods demonstrate a stability within 2 ppm, exceeding KATRIN's specifications.

physics.ins-det

Cryogenic bath-type heat exchangers for ultra-pure noble gas applications

Two cryogenic bath-type heat exchangers for ultra-pure noble gas applications were developed with particular emphasis on noble gas liquefaction in cryogenic distillation systems. The main objective was to construct heat exchangers for xenon from materials that do not emanate radon and that fulfill ultra-high vacuum standards. Therefore, only high-quality copper and stainless steel materials were used. Especially, large-area oxygen-free copper fins with high conductivity in a new design ensure efficient heat transfer. One bath-type Xe-Xe heat exchanger was designed with a diameter of 50 cm to achieve a xenon condensing capacity of at least 100 kg/h. In order to guarantee the necessary heat transfer between the two xenon reservoirs, this heat exchanger features a specially manufactured stainless steel flange with a copper plate welded inside. We first tested our concept on a dedicated bath-type heat exchanger with a reduced diameter of 30 cm using liquid nitrogen to liquefy the xenon. A model based on conservative assumptions such as film boiling on the nitrogen side and film condensation on the xenon side was developed and applied to caluclate the expected heat transfer for our design. We were able to demonstrate an adjustable xenon liquefaction rate of up to 113 kg/h limited only by our measurement procedure at a cooling efficiency of $(0.98\pm 0.03)$ for the LN$_2$-Xe heat exchanger.

physics.ins-det

High resolution MCP-PMT Readout Using Transmission Lines

We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection module for the positron emission tomography using the liquid detection media, the tri-methyl bismuth. In this study we use the commercial MCP-PMT Planacon from Photonis, with 32x32 anode structure. The PCB gathers signals from anode pads in 32 transmission lines which are read-out from both ends. Amplifier boards and SAMPIC modules, developed in our labs, allow us to realize the cost-effective, multi-channel digitization of signals with excellent precision. For a single photo-electron, we measured a time resolution of 70~ps (FWHM) simultaneously with a spatial accuracy of 1.6~mm and 0.9~mm (FWHM) along and across transmission lines correspondingly.

physics.ins-det

Ultra-clean radon-free four cylinder magnetically-coupled piston pump

A high performance gas displacement pump based on four individual cylinders was developed. The magnetically-coupled pistons and the hermetically-sealed housings as well as the special cleanliness in terms of out-gassing and radio-purity make the four cylinder pump interesting for the usage in low background experiments dealing with noble gases as target. An optimized inner flow path as well as reduced dead volume with respect to the prototype single cylinder pump of the XENON1T experiment combined with advanced polymer piston gaskets and a piston coupling force of (3177 $\pm$ 162) N ensures a high and reliable performance. Furthermore, a phase-shifted synchronization of the pistons' movement creates an additional performance boost as well as minimizes fluctuations of flow and compression. The pump is able to generate xenon flows of 474 slpm at a pressure difference of 1.80 bar.

physics.ins-det

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

physics.ins-det

Laser spectroscopy of the $^2S_{1/2} - ^2P_{1/2}$, $^2P_{3/2}$ transitions in stored and cooled relativistic C$^{3+}$ ions

The $^2S_{1/2} - ^2P_{1/2}$ and $^2S_{1/2} - ^2P_{3/2}$ transitions in Li-like carbon ions stored and cooled at a velocity of $β\approx 0.47$ in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry has been resolved and agreement between experiment and theory is confirmed.

physics.atom-ph

KATRIN background due to surface radioimpurities

The goal of the KArlsruhe TRItrium Neutrino (KATRIN) experiment is the determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^2$ at 90% C.L. This goal can only be achieved with a very low background level in the order of 0.01 counts per second. A possible background source is $α$-decays on the inner surface of the KATRIN Main Spectrometer. Two $α$-sources, $^{223}$Ra and $^{228}$Th, were installed at the KATRIN Main Spectrometer with the purpose of temporarily increasing the background in order to study $α$-decay induced background processes. In this paper, we present a possible background generation mechanism and measurements performed with these two radioactive sources. Our results show a clear correlation between $α$-activity on the inner spectrometer surface and background from the volume of the spectrometer. Two key characteristics of the Main Spectrometer background -the dependency on the inner electrode offset potential, and the radial distribution - could be reproduced with this artificially induced background. These findings indicate a high contribution of $α$-decay induced events to the residual KATRIN background.

physics.ins-det

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

physics.ins-det

MeV neutrino dark matter: Relic density, lepton flavour violation and electron recoil

Right-handed neutrinos with MeV to GeV mass are very promising candidates for dark matter (DM). Not only can they solve the missing satellite puzzle, the cusp-core problem of inner DM density profiles, and the too-big-to fail problem, {\it i.e.} that the unobserved satellites are too big to not have visible stars, but they can also account for the Standard Model (SM) neutrino masses at one loop. We perform a comprehensive study of the right-handed neutrino parameter space and impose the correct observed relic density and SM neutrino mass differences and mixings. We find that the DM masses are in agreement with bounds from big-bang nucleosynthesis, but that these constraints induce sizeable DM couplings to the charged SM leptons. We then point out that previously overlooked limits from current and future lepton flavour violation experiments such as MEG and SINDRUM heavily constrain the allowed parameter space. Since the DM is leptophilic, we also investigate electron recoil as a possible direct detection signal, in particular in the XENON1T experiment. We find that despite the large coupling and low backgrounds, the energy thresholds are still too high and the predicted cross sections too low due to the heavy charged mediator, whose mass is constrained by LEP limits.

hep-ph