SearcharxivSearch

arXiv subjects

C. Woody

Publications and source records attributed to C. Woody.

11 recordsLinked to original sources

Performance of an HRPPD in Tesla-scale magnetic fields

High-Rate Picosecond Photodetectors (HRPPDs) are state-of-the-art microchannel-plate (MCP) photodetectors that offer excellent timing and spatial resolution, together with high single-photon detection efficiency. They are currently being considered for the ePIC experiment at the future Electron Ion Collider (EIC) at Brookhaven National Laboratory. A key requirement for the application of this technology is reliable operation in a strong magnetic field up to 1.5 T, with magnetic flux lines at an inclination of $\le15^\circ$ to the normal of the MCP surface. Magnetic field-induced distortions of the collected charge in MCP-based detectors can be compensated by tuning the operating parameters; however, the objective of this study is to quantify this performance in the case of the EIC-HRPPD, a particular MCP stack-up specialized for operation within ePIC. This photosensor employs a high quantum efficiency photocathode, 10$~\mu$m capillary pores, narrow transfer gaps, and a custom ceramic pixelated DC-coupled readout. This article explores the optimal operating parameters (mainly the voltages applied across the gaps and the MCPs) for single photon detection at various inclination angles in a uniform field up to 1.8 T. Ultimately, it was found that the gain and single photon detection efficiency of the HRRPD could be recovered over a range of polar inclination angles up to $\pm35^\circ$.

physics.ins-det

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven 'EIC HRPPDs' was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 x 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15-20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can also provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

physics.ins-det

A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent positional information, the lateral spacing of the straight pads must be significantly smaller than the extent of the charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the charge with a pitch comparable to the size of the charge cloud or even larger. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a uniform detector response without the need for so-called pad response functions, while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag shaped anode patterns optimized for various MPGDs, including GEM, Micromegas, and micro-RWELL and compared this performance to the same detectors equipped with straight pads of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.

physics.ins-det

Hadron Blind Cherenkov Counters

In this paper, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons though their $e^+e^-$ decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

physics.ins-det

Results from a Prototype Combination TPC Cherenkov Detector with GEM Readout

A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. The TPC portion consists of a 10x10x10cm3 field cage, which delivers charge from tracks to a 10x10cm2 quadruple GEM readout. Tracks are reconstructed by interpolating the hit position of clusters on an array of 2x10mm2 zigzag pads The Cherenkov component consists of a 10x10cm2 readout plane segmented into 3x3 square pads, also coupled to a quadruple GEM. As tracks pass though the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the CsI photocathode of the Cherenkov detector. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, as well as results on its particle id capabilities will be discussed.

physics.ins-det

Design Studies for a TPC Readout Plane Using Zigzag Patterns with Multistage GEM Detectors

A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each pad layer is required to provide a spatial resolution of ~250 microns, which must be achieved with a minimal channel count in order to minimize the overall cost of the detector. The current proposal is to make the pads into a zigzag shape in order to enhance charge sharing among neighboring pads. This will allow for the possibility to interpolate the hit position to high precision, resulting in a position resolution many times better than the 2mm pitch of the readout pads. This paper discusses various simulation studies that were carried out to optimize the size and shape of the zigzag pads for the readout board for the TPC, along with the technical challenges in fabricating it. It also describes the performance of the first prototype readout board obtained from measurements carried out in the laboratory using a highly collimated X-ray source.

physics.ins-det

A Study of a Mini-drift GEM Tracking Detector

A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a small drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 micron pitch XY strips and the other consisted of 2x10mm2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Applications for large angle tracking detectors at RHIC and EIC are also discussed.

physics.ins-det

Design, Construction, Operation and Performance of a Hadron Blind Detector for the PHENIX Experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF4. It has a 50 cm long radiator directly coupled in a window- less configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

physics.ins-det

Development of Tracking Detectors with industrially produced GEM Foils

The planned tracking upgrade of the STAR experiment at RHIC includes a large-area GEM tracker used to determine the charge sign of electrons and positrons produced from W+(-) decays. For such a large-scale project commercial availability of GEM foils is necessary. We report first results obtained with a triple GEM detector using GEM foils produced by Tech-Etch Inc. of Plymouth, MA, USA. Measurements of gain uniformity, long-term stability as well as measurements of the energy resolution for X-Rays are compared to results obtained with an identical detector using GEM foils produced at CERN. A quality assurance procedure based on optical tests using an automated high-resolution scanner has been established, allowing a study of the correlation of the observed behavior of the detector and the geometrical properties of the GEM foils. Detectors based on Tech-Etch and CERN produced foils both show good uniformity of the gain over the active area and stable gain after an initial charge-up period, making them well suited for precision tracking applications.

physics.ins-det

A Hadron Blind Detector for the PHENIX Experiment at RHIC

A Hadron Blind Detector (HBD) is being developed for the PHENIX experiment at RHIC. It consists of a Cherenkov radiator operated with pure CF4 directly coupled in a windowless configuration to a triple-GEM detector element with a CsI photocathode and pad readout. The HBD operates in the bandwidth 6-11.5 eV(110-200 nm). We studied the detector response to minimum ionizing particles and to electrons. We present measurements of the CsI quantum efficiency, which are in very good agreement with previously published results over the bandwidth 6-8.3 eV and extend them up to 10.3 eV. Discharge probability andaging studies of the GEMs and the CsI photocathode in pure CF4 are presented.

physics.ins-det

Proposal for a Hadron Blind Detector for PHENIX

A Hadron Blind Detector (HBD) is proposed as upgrade of the PHENIX detector at RHIC, BNL. The HBD will allow the measurement of low-mass e+e- pairs from the decay of the light vector mesons rho, omega, phi and the low-mass continuum in Au-Au collisions at energies up to sqrt{s_{NN}}= 200 GeV. From MC simulations and general considerations, the HBD has to identify electrons with very high efficiency (> 90%), double hit recognition better than 90%, moderate pion rejection factor of ~200 and radiation budget of the order of 1% of a radiation length. The first choice under study is a windowless Cherenkov detector, operated with pure CF4, in a special proximity focus configuration with a CsI photocathode and a multistage GEM amplification element.

physics.ins-det