SearcharxivSearch

arXiv subjects

C. Y. Li

Publications and source records attributed to C. Y. Li.

At least 19 recordsLinked to original sources

Collective expansion in pp collisions using the Tsallis statistics

We investigate the transverse momentum ($p_{\rm T}$) spectra of identified hadrons in minimum-bias proton-proton (pp) collisions at a centre-of-mass energy ($\sqrt{s}$) of 0.9, 2.76, 5.02, 7 and 13 TeV in the framework of Tsallis-blast wave (TBW) model. It is found that the model describes well the particle spectra up to 10 GeV/c. The radial flow ($\langle β\rangle$) increases with the collision energy. The degrees of non-equilibrium ($q$) and the Tsallis temperature parameter ($T$) show a similar behaviour, but with a much weaker trend. With this dependence of the freeze-out parameters on the collision energy, we evaluate $\langle β\rangle$, $T$ and $q$ in pp collisions at $\sqrt{s}=$ 8 and 14 TeV and predict the particle spectra at these two energies. Moreover, in order to investigate the multiplicity dependence of the freeze-out parameters, the TBW model is extended to the spectra at different charged-particle multiplicity classes in pp collisions at $\sqrt{s}=$ 7 and 13 TeV. It is observed that at both energies the radial flow increases with the multiplicity while the degree of non-equilibrium shows an opposite behaviour, which is similar to that observed in proton-nucleus (pA) and nucleus-nucleus (AA) collisions at the Large Hadron Collider (LHC) energies. However, the Tsallis temperature parameter increases with the multiplicity, which is opposite to the trend in pA and AA collisions. At similar multiplicities, the radial flow in pp collisions is stronger than those in pA and AA collisions, indicating that the size of the colliding system has significant effects on the final state particle dynamics. Finally, we apply an additional flow correction to the Tsallis temperature parameter and find that the doppler-corrected temperature parameter almost scales with the multiplicity in a uniform way, despite the difference in the colliding system and collision energy.

nucl-th

The Design and Performance of Charged Particle Detector onboard the GECAM Mission

The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.

astro-ph.IM

Quality assurance test and Failure Analysis of SiPM Arrays of GECAM Satellites

The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.

physics.ins-det

Dedicated SiPM array for GRD of GECAM

The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.

hep-ex

Inflight performance of the GECAM Gamma-ray and Charge particle Detectors

The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020 , we carried out a series of on orbit tests. This paper introduces the test results of the GECAM-B satellite. According to the in-flight performance, the energy band for gamma-ray detection of GECAM-B is from about 7 keV to 3.5 MeV. GECAM-B can achieve prompt localization of GRBs. For the first time, GECAM-B realized a quasi-real-time transmission of trigger information using Beidou-3 RDSS. Keywords GECAM, gamma-ray burst, gravitational wave, GRD, CPD

physics.ins-det

The SiPM Array Data Acquisition Algorithm Applied to the GECAM Satellite Payload

The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array data is designed and implemented, and the output event packet is defined. Finally, the algorithm's efficacy for event acquisition is verified.

astro-ph.IM

Ground-based calibration and characterization of GRD of GECAM: 8-160 keV

As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.

astro-ph.IM

The design and performance of GRD onboard the GECAM satellite

Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.

astro-ph.IM

GECAM detection of a bright type-I X-ray burst from 4U 0614+09: confirmation its spin frequency at 413 Hz

One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered with \textit{Swift}/BAT \citep{Strohmayer2008}, and therefore confirms the spin frequency of this source. This burst is the brightest one in the normal bursts (except the superburst) ever detected from 4U~0614+09, which leads to an upper limit of distance estimation as 3.1 kpc. The folded light curve during the burst oscillation shows a multi-peak structure, which is the first case observed during a single burst oscillation in nonpulsating sources. The multi-peak profile could be due to additional harmonics of the burst oscillation, which is corresponding to several brighter/fainter spots at the stellar surface.

astro-ph.HE

Intercomparison of Monte Carlo calculated dose enhancement ratios for gold nanoparticles irradiated by X-rays: assessing the uncertainty and correct methodology for extended beams

Results of a Monte Carlo code intercomparison exercise for simulations of the dose enhancement from a gold nanoparticle (GNP) irradiated by X-rays have been recently reported. To highlight potential differences between codes, the dose enhancement ratios (DERs) were shown for the narrow-beam geometry used in the simulations, which leads to values significantly higher than unity over distances in the order of several tens of micrometers from the GNP surface. As it has come to our attention that the figures in our paper have given rise to misinterpretation as showing 'the' DERs of GNPs under diagnostic X-ray irradiation, this article presents estimates of the DERs that would have been obtained with realistic radiation field extensions and presence of secondary particle equilibrium (SPE). These DER values are much smaller than those for a narrow-beam irradiation shown in our paper, and significant dose enhancement is only found within a few hundred nanometers around the GNP. The approach used to obtain these estimates required the development of a methodology to identify and, where possible, correct results from simulations whose implementation deviated from the initial exercise definition. Based on this methodology, literature on Monte Carlo simulated DERs has been critically assessed.

physics.med-ph

Theoretical studies of the optical and EPR spectra for VO$^{2+}$ in Na$_{3}$C$_{6}$H$_{5}$O$_{7}\cdot 2$H$_{2}$O single crystal

On the basis of the perturbation formulas for a $d^{1}$ configuration ion in a tetragonal crystal field, the three optical absorption bands and electron paramagnetic resonance (EPR) parameters ($g$ factors $g_{i}$ and hyperfine structure constants $A_{i}$ for $i = \|$ and $\perp$, respectively) of VO$^{2+}$ in Na$_{3}$C$_{6}$H$_{5}$O$_{7}\cdot2$H$_{2}$O single crystals were studied using the perturbation theory method. By simulating the calculated optical and EPR spectra to the observed values, local structure parameters and negative signs of the hyperfine structure constants $A_{i}$ of the octahedral (VO$_{6}$)$^{8-}$ cluster in trisodium citrate dehydrate single crystal can be obtained.

cond-mat.mtrl-sci

Enhanced collectivity in neutron-deficient Sn isotopes in energy functional based collective Hamiltonian

The low-lying collective states in Sn isotopes are studied by a five-dimensional collective Hamiltonian with parameters determined from the triaxial relativistic mean-field calculations using the PC-PK1 energy density functional. The systematics for both the excitation energies of $2^+_1$ states and $B(E2;0^+_1\to 2^+_1)$ values are reproduced rather well, in particular, the enhanced E2 transitions in the neutron-deficient Sn isotopes with N<66. We show that the gradual degeneracy of neutron levels 1g7/2 and 2d5/2 around the Fermi surface leads to the increase of level density and consequently the enhanced paring correlations from N=66 to 58. It provokes a large quadrupole shape fluctuation around the spherical shape, and leads to an enhanced collectivity in the isotopes around N=58.

nucl-th

Universal Scaling of Pinning Effect on Hall Anomaly near the Vortex Glass Transition and Doping Dependence Problems of Superconductors

We find universal scaling relations of the pinning effect on the Hall resistivity $ρ_{xy}$ and Hall angle $θ_{H}$. Considering the extended power law form of $ρ_{xx}$ and the microscopic analysis of $σ_{xy}$, we obtain unified $ρ_{xy}$ equations for superconductors with and without double sign reversal. These equations reasonably explain the striking universality in doping dependence found by Nagoaka et al., which contradicts the prediction of the time dependent Ginzburg-Landau equation based on s-wave coupling theory [PRL {\bf{80}},3594 (1998)]. A full comparison of experiment with prediction from theoretical models is proposed.

cond-mat.supr-con

Optical properties of boron-doped diamond

We report optical reflectivity study on pure and boron-doped diamond films grown by a hot-filament chemical vapor deposition method. The study reveals the formation of an impurity band close to the top of the valence band upon boron-doping. A schematic picture for the evolution of the electronic structure with boron doping was drawn based on the experimental observation. The study also reveals that the boron doping induces local lattice distortion, which brings an infrared-forbidden phonon mode at 1330 cm$^{-1}$ activated in doped sample. The antiresonance characteristic of the mode in conductivity spectrum evidences the very strong coupling between electrons and this phonon mode.

cond-mat.supr-con

Scaling of Nonlinear Longitudinal and Hall Resistivities near the Vortex Glass Transition

We show that the longitudinal current-voltage characteristics of superconductors in mixed state have the general form of extended power law. Isotherms simulated from this nonlinear equation fit the experimental I-V data of Strachan et al. [ Phys. Rev. Lett. {\bf 87}, 067007 (2001)]. We determine the average pinning force in the flux creep and strong pinning regime and discuss both the puzzling scaling behavior $ρ_{xy}\proptoρ_{xx}^β$ and a recently found new scaling relationship of nonlinear Hall resistivity $ρ_{xy}(T)$.

cond-mat.supr-con

Image of Veselago lens based upon two-dimensional photonic crystal with triangular lattice

The construction of the multi-focal Veselago lens predicted earlier is proposed on the basis of a uniaxial photonic crystal consisting of cylindrical air holes in silicon that make a triangular lattice in a plane perpendicular to the axis of the crystal. The object and image are in air. The period of the crystal should be $0.44μ{\rm m}$ to work at the wavelength $1.5μ{\rm m}$. The lens does not provide superlensing but the half-width of the image is $0.5λ$. The lens is shown to have wave guiding properties depending on the substrate material.

cond-mat.mtrl-sci

Far-field image of Veselago lens

It is shown that perfect imaging of a point source both in near- and far-field regions contradicts electrodynamics although ``superlensing'' is impossible only in the far-field region. These general statements are illustrated by detailed study of evanescent wave propagation in a photonic crystal that is known to be a left-handed medium. An analytical expression for the intensity distribution near the far-field focus is obtained. This distribution contains some novel features and establishes a new ``diffraction limit'' for flat lenses. It is generalized for multiple sources located at different points. The distribution is in very good agreement with computer simulation.

cond-mat.mtrl-sci

Evanescent waves in photonic crystals and image of Veselago lens

It is shown that negative electric permittivity and magnetic permeability recently discovered in a photonic crystal in the vicinity of the Gamma-point are properties of propagating modes only. The evanescent modes rather decay than increase in the bulk of the crystal though they may be amplified by surface waves. If surface support such waves, the evanescent waves may improve the image of a thin Veselago lens. It is shown that a ``perfect lens'' contradicts to the wave optics and a criterion of ``superlensing'' is formulated.

cond-mat.mtrl-sci