Searcharxiv⌕ Search

arXiv subjects

C. Zhang

Publications and source records attributed to C. Zhang.

At least 253 records · Page 14Linked to original sources

Update on the MiniCLEAN Dark Matter Experiment

The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.

physics.ins-det↗

Locality and universality of quantum memory effects

Recently, a series of different measures quantifying memory effects in the quantum dynamics of open systems has been proposed. Here, we derive a mathematical representation for the non-Markovianity measure based on the exchange of information between the open system and its environment which substantially simplifies its numerical and experimental determination, and fully reveals the locality and universality of non-Markovianity in the quantum state space. We further illustrate the application of this representation by means of an all-optical experiment which allows the measurement of the degree of memory effects in a photonic quantum process with high accuracy.

quant-ph↗

Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector

The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.

astro-ph.IM↗

A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment

LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.

hep-ex↗

Observation of Pure Spin Transport in a Diamond Spin Wire

Spin transport electronics - spintronics - focuses on utilizing electron spin as a state variable for quantum and classical information processing and storage. Some insulating materials, such as diamond, offer defect centers whose associated spins are well-isolated from their environment giving them long coherence times; however, spin interactions are important for transport, entanglement, and read-out. Here, we report direct measurement of pure spin transport - free of any charge motion - within a nanoscale quasi 1D 'spin wire', and find a spin diffusion length ~ 700 nm. We exploit the statistical fluctuations of a small number of spins ($\sqrt{N}$ < 100 net spins) which are in thermal equilibrium and have no imposed polarization gradient. The spin transport proceeds by means of magnetic dipole interactions that induce flip-flop transitions, a mechanism that can enable highly efficient, even reversible, pure spin currents. To further study the dynamics within the spin wire, we implement a magnetic resonance protocol that improves spatial resolution and provides nanoscale spectroscopic information which confirms the observed spin transport. This spectroscopic tool opens a potential route for spatially encoding spin information in long-lived nuclear spin states. Our measurements probe intrinsic spin dynamics at the nanometre scale, providing detailed insight needed for practical devices which seek to control spin.

cond-mat.mes-hall↗

Measuring Double-Electron Capture with Liquid Xenon Experiments

We investigate the possibilities of observing the decay mode for $^{124}$Xe in which two electrons are captured, two neutrinos are emitted, and the final daughter nucleus is in its ground state, using dark matter experiments with liquid xenon. The first upper limit of the decay half-life is calculated to be 1.66$\times10^{21}$ years at a 90% confidence level (C.L.) obtained with the published background data from the XENON100 experiment. Employing a known background model from the Large Underground Xenon (LUX) experiment, we predict that the detection of double-electron capture of $^{124}$Xe to the ground state of $^{124}$Te with LUX will have approximately 115 events, assuming a half-life of 2.9 $\times$ 10$^{21}$ years. We conclude that measuring $^{124}$Xe 2$ν$ double-electron capture to the ground state of $^{124}$Te can be performed more precisely with the proposed LUX-Zeplin (LZ) experiment.

nucl-ex↗

Laboratory Studies on the Removal of Radon-Born Lead from KamLAND's Organic Liquid Scintillator

The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.

physics.ins-det↗

Neutrino mass hierarchy determination and other physics potential of medium-baseline reactor neutrino oscillation experiments

Medium-baseline reactor neutrino oscillation experiments (MBRO) have been proposed to determine the neutrino mass hierarchy (MH) and to make precise measurements of the neutrino oscillation parameters. With sufficient statistics, better than ~3%/\sqrt{E} energy resolution and well understood energy non-linearity, MH can be determined by analyzing oscillation signals driven by the atmospheric mass-squared difference in the survival spectrum of reactor antineutrinos. With such high performance MBRO detectors, oscillation parameters, such as \sin^22θ_{12}, Δm^2_{21}, and Δm^2_{32}, can be measured to sub-percent level, which enables a future test of the PMNS matrix unitarity to ~1% level and helps the forthcoming neutrinoless double beta decay experiments to constrain the allowed values. Combined with results from the next generation long-baseline beam neutrino and atmospheric neutrino oscillation experiments, the MH determination sensitivity can reach higher levels. In addition to the neutrino oscillation physics, MBRO detectors can also be utilized to study geoneutrinos, astrophysical neutrinos and proton decay. We propose to start a U.S. R&D program to identify, quantify and fulfill the key challenges essential for the success of MBRO experiments.

hep-ex↗

The CAPTAIN Detector and Physics Program

The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented with a 2,000 channel liquid argon TPC and a photon detection system. Subsequent to the commissioning phase, the detector will collect data in a high-energy neutron beamline that is part of the Los Alamos Neutron Science Center to measure cross-sections of spallation products that are backgrounds to measurements of neutrinos from a supernova burst, cross-sections of events that mimic the electron neutrino appearance signal in long-baseline neutrino physics and neutron signatures to constrain neutrino energy reconstruction in LBNE's long-baseline program. Subsequent to the neutron running, the CAPTAIN detector will be moved to a neutrino source. Two possibilities are an on-axis run in the NuMI beamline at FNAL and a run in the neutrino source produced by the SNS. An on-axis run at NuMI produces more than one million events of interest in a two or three year run at neutrino energies between 1 and 10 GeV - complementary to the MicroBooNE experiment, which will measure similar interactions at a lower energy range - 0.5 to 2 GeV. At the SNS the neutrinos result from the decays stopped positively charged pions and muons yielding a broad spectrum up to 50 MeV. If located close to the spallation target, CAPTAIN can detect several thousand events per year in the same neutrino energy regime where neutrinos from a supernova burst are. Measurements at the SNS yield a first measurement of the cross- section of neutrinos on argon in this important energy regime.

physics.ins-det↗

Unitarity Tests of the Neutrino Mixing Matrix

We discuss unitarity tests of the neutrino mixing (PMNS) matrix. We show that the combination of solar neutrino experiments, medium-baseline and short-baseline reactor antineutrino experiments make it possible to perform the first direct unitarity test of the PMNS matrix. In particular, the measurements of Daya Bay and JUNO (a next generation medium-baseline reactor experiment) will lay the foundation of a precise unitarity test of $|U_{e1}|^2 + |U_{e2}|^2 + |U_{e3}|^2 = 1 $. Furthermore, the precision measurement of $\sin^22θ_{13}$ in both the $\barν_e$ disappearance and the $ν_e$ appearance (from a $ν_μ$ beam) channels will provide an indirect unitarity test of the PMNS matrix. Together with the search for appearance/disappearance at very short distances, these tests could provide important information about the possible new physics beyond the three-neutrino model.

hep-ex↗

A Second Detector Focusing on the Second Oscillation Maximum at an Off-axis Location to Enhance the Mass Hierarchy Discovery Potential in LBNE10

The Long Baseline Neutrino Oscillation Experiment (LBNE) is proposed to determine the neutrino mass hierarchy and measure the CP phase in the leptonic sector. The current design of LBNE Phase I consists of a 10 kt liquid argon time projection chamber (LBNE10). The neutrino-antineutrino asymmetry in the electron-neutrino appearance probability has contributions from both the CP phase and the matter effect. For this reason, experimental sensitivity to the mass hierarchy depends both on the true value of the CP phase and the true mass hierarchy; LBNE10 will determine the mass hierarchy at high levels of significance for half of CP phase space. We propose placing a second detector at an off-axis location. Such a detector will share the same beamline as the primary LBNE detector. The detector location is chosen such that this detector focuses on a measurement of electron (anti-)neutrino appearance at the second oscillation maximum. We will show that this configuration will enhance the ability of LBNE to determine the mass hierarchy and to discover CP violation in the leptonic sector.

hep-ex↗

Optimizing the superconducting transition temperature and upper critical field of Sn(1-x)In(x)Te

Sn(1-x)In(x)Te is a possible candidate for topological superconductivity. Previous work has shown that substitution of In for Sn in the topological crystalline insulator SnTe results in superconductivity, with the transition temperature, Tc, growing with In concentration. We have performed a systematic investigation of Sn(1-x)In(x)Te for a broad range of x, synthesizing single crystals (by a modified floating zone method) as well as polycrystalline samples. The samples have been characterized by x-ray diffraction, resistivity, and magnetization. For the single crystals, the maximum Tc is obtained at x=0.45 with a value of of 4.5 K, as determined by the onset of diamagnetism.

cond-mat.supr-con↗

An Ultra-Low Background PMT for Liquid Xenon Detectors

Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.

physics.ins-det↗

Observability Inequalities and Measurable Sets

This paper presents two observability inequalities for the heat equation over $Ω\times(0,T)$. In the first one, the observation is from a subset of positive measure in $Ω\times(0,T)$, while in the second, the observation is from a subset of positive surface measure in $\partialΩ\times(0,T)$. It also proves the Lebeau-Robbiano spectral inequality when $Ω$ is a bounded Lipschitz and locally star-shaped domain. Some applications for the above-mentioned observability inequalities are provided.

math.AP↗

Measuring Fast Neutrons with Large Liquid Scintillation Detector for Ultra-low Background Experiments

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical volume coated on the inside with reflective paint (95% reflectivity) that significantly increases the detector's light collection. We demonstrate several calibration techniques using point sources and cosmic-ray muons for energies up to 20 MeV for this large liquid scintillation detector. Neutron-gamma separation using pulse shape discrimination with a few MeV neutrons to hundreds of MeV neutrons is shown for the first time using a large liquid scintillator.

physics.ins-det↗

Ionization Efficiency Study for Low Energy Nuclear Recoils in Germanium

We used the internal conversion ($E_0$ transition) of germanium-72 to indirectly measure the low energy nuclear recoils of germanium. Together with a reliable Monte Carlo package, in which we implement the internal conversion process, the data was compared to the Lindhard ($k$=0.159) and Barker-Mei models. A shape analysis indicates that both models agree well with data in the region of interest within 4%. The most probable value (MPV) of the nuclear recoils obtained from the shape analysis is 17.5 keV with an average path-length of 0.014 $μ$m.

physics.ins-det↗

Automated Calibration System for a High-Precision Measurement of Neutrino Mixing Angle $θ_{13}$ with the Daya Bay Antineutrino Detectors

We describe the automated calibration system for the antineutrino detectors in the Daya Bay Neutrino Experiment. This system consists of 24 identical units instrumented on 8 identical 20-ton liquid scintillator detectors. Each unit is a fully automated robotic system capable of deploying an LED and various radioactive sources into the detector along given vertical axes. Selected results from performance studies of the calibration system are reported.

physics.ins-det↗

Depth Requirements for a Tonne-scale 76Ge Neutrinoless Double-beta Decay Experiment

Neutrinoless double-beta decay experiments can potentially determine the Majorana or Dirac nature of the neutrino, and aid in understanding the neutrino absolute mass scale and hierarchy. Future 76Ge-based searches target a half-life sensitivity of >10^27 y to explore the inverted neutrino mass hierarchy. Reaching this sensitivity will require a background rate of <1 count tonne^-1 y^-1 in a 4-keV-wide spectral region of interest surrounding the Q value of the decay. We investigate the overburden required to reach this background goal in a tonne-scale experiment with a compact (copper and lead) shield based on Monte Carlo calculations of cosmic-ray background rates. We find that, in light of the presently large uncertainties in these types of calculations, a site with an underground depth >~5200 mwe is required for a tonne-scale experiment with a compact shield similar to the planned 40-kg MAJORANA DEMONSTRATOR. The required overburden is highly dependent on the chosen shielding configuration and could be relaxed significantly if, for example, a liquid cryogen and water shield, or an active neutron shield were employed. Operation of the MAJORANA DEMONSTRATOR and GERDA detectors will serve to reduce the uncertainties on cosmic-ray background rates and will impact the choice of shielding style and location for a future tonne-scale experiment. 4/2013: The peer review process revealed that one of the veto rejection factors (the factor-of-4 described on p12) needs to be better established. Our reevaluation of this parameter to date has not yielded strong support for the value stated in the manuscript, and we require further study to develop a solid estimate. This further study will supersede the work described in this manuscript, and may or may not lead to the same conclusion regarding the ~>5200 mwe requirement for future tonne-scale 76Ge neutrinoless double beta decay experiments.

nucl-ex↗