Searcharxiv⌕ Search

arXiv subjects

C. Zhao

Publications and source records attributed to C. Zhao.

24 records · Page 2Linked to original sources

Observation of the Three-Mode Parametric Instability

Three-mode parametric interactions occur in triply-resonant optomechanical systems: photons from an optical pump mode are coherently scattered to a high-order mode by mechanical motion of the cavity mirrors, and these modes resonantly interact via radiation pressure force when certain conditions are met. Such effects are predicted to occur in long baseline advanced gravitational-wave detectors. They can pump energy into acoustic modes, leading to parametric instability, but they can also extract acoustic energy, leading to optomechanical cooling. We develop a large amplitude model of three-mode interactions that explains the ring-up amplitude saturation after instability occurs. We also demonstrate both radiation-pressure cooling and mechanical amplification in two different three-mode optomechanical systems, including the first observation of the three-mode parametric instability in a free-space Fabry-Perot cavity. The experimental data agrees well with the theoretical model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques to overcome instability.

physics.optics↗

Three-mode opto-acoustic parametric interactions with coupled cavity

We theoretically analyze three-mode opto-acoustic parametric interactions in a coupled Fabry-Perot cavity, where one acoustic mode interacts with two optical modes. We show explicitly that extra degrees of freedom in a coupled cavity allow explorations of both parametric instability and cooling regimes with high parametric gain in a single table top experiment. This work can motivate experimental realizations of the three-mode parametric instability which might be an issue in next-generation gravitational-wave detectors with high optical-power cavities, helping in the development of better models, and in developing techniques for controls. In addition, we show that the same scheme can be implemented in the resolved-sideband acoustic-mode cooling.

physics.optics↗

Observation of Three Mode Parametric Interactions in Long Optical Cavities

We report the first observation of three-mode opto-acoustic parametric interactions of the type predicted to cause parametric instabilities in an 80 m long, high optical power cavity that uses suspended sapphire mirrors. Resonant interaction occurs between two distinct optical modes and an acoustic mode of one mirror when the difference in frequency between the two optical cavity modes is close to the frequency of the acoustic mode. Experimental results validate the theory of parametric instability in high power optical cavities.

gr-qc↗

Time transfer by laser link between China and France

To advance from milli-arcsecond to micro-arcsecond astrometry, time keeping capability and its comparison among different stations need to be improved and enhanced. The T2L2 (Time transfer by laser link) experiment under development at OCA and CNES to be launched in 2008 on Jason-2, allows the synchronization of remote clocks on Earth. It is based on the propagation of light pulses in space which is better controlled than the radio waves propagation. In this paper, characteristics are presented for both common view and non-common view T2L2 comparisons of clocks between China and France.

astro-ph↗

Compensation of Strong Thermal Lensing in High Optical Power Cavities

In an experiment to simulate the conditions in high optical power advanced gravitational wave detectors such as Advanced LIGO, we show that strong thermal lenses form in accordance with predictions and that they can be compensated using an intra-cavity compensation plate heated on its cylindrical surface. We show that high finesse ~1400 can be achieved in cavities with internal compensation plates, and that the cavity mode structure can be maintained by thermal compensation. It is also shown that the measurements allow a direct measurement of substrate optical absorption in the test mass and the compensation plate.

gr-qc↗

Parametric instabilities and their control in advanced interferometer GW detectors

A detailed simulation of Advanced LIGO test mass optical cavities shows that parametric instabilities will excite acoustic modes in the test masses in the frequency range 28-35 kHz and 64-72 kHz. Using nominal Advanced LIGO optical cavity parameters with fused silica test masses, parametric instability excites 7 acoustic modes in each test mass, with parametric gain R up to 7. For the alternative sapphire test masses only 1 acoustic mode is excited in each test mass with R ~ 2. Fine tuning of the test mass radii of curvature cause the instabilities to sweep through various modes with R as high as ~2000. Sapphire test mass cavities can be tuned to completely eliminate instabilities using thermal g-factor tuning with negligible degradation of the noise performance. In the case of fused silica test mass, instabilities can be minimized but not eliminated.

gr-qc↗