SearcharxivSearch

arXiv subjects

C. Zorn

Publications and source records attributed to C. Zorn.

9 recordsLinked to original sources

Deeply virtual Compton scattering using a positron beam in Hall-C at Jefferson Lab

We propose to use the High Momentum Spectrometer of Hall C combined with the Neutral Particle Spectrometer (NPS) to perform high precision measurements of the Deeply Virtual Compton Scattering (DVCS) cross section using a beam of positrons. The combination of measurements with oppositely charged incident beams is the only unambiguous way to disentangle the contribution of the DVCS$^2$ term in the photon electroproduction cross section from its interference with the Bethe-Heitler amplitude. This provides a stronger way to constrain the Generalized Parton Distributions of the nucleon. A wide range of kinematics accessible with an 11 GeV beam off an unpolarized proton target will be covered. The $Q^2-$dependence of each contribution will be measured independently.

nucl-ex

AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case

Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. We propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as part of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our approach can be applied to any detector R&D, provided that realistic simulations are available.

physics.ins-det

High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A

The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0p-shell region of nuclei such as the hypernuclei produced in electroproduction on 9Be, 12C and 16O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. For the first time, measurable strength with sub-MeV energy resolution was observed for the core-excited states of Lambda 12B. A high-quality Lambda 16N hypernuclear spectrum was likewise obtained. A first measurement of the Lambda binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 +/- 0.16 MeV. Similarly, the first Lambda 9Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Lambda separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been shown that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the gamma-ray spectroscopy technique.

nucl-ex

Spectroscopy of Lambda-9Li by electroproduction

In the absence of accurate data on the free two-body hyperon-nucleon interaction, the spectra of hypernuclei can provide information on the details of the effective hyperon-nucleon interaction. Electroproduction of the hypernucleus Lambda-9Li has been studied for the first time with sub-MeV energy resolution in Hall A at Jefferson Lab on a 9Be target. In order to increase the counting rate and to provide unambiguous kaon identification, two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. The cross section to low-lying states of Lambda-9Li is concentrated within 3 MeV of the ground state and can be fitted with four peaks. The positions of the doublets agree with theory while a disagreement could exist with respect to the relative strengths of the peaks in the doublets. A Lambda separation energy of 8.36 +- 0.08 (stat.) +- 0.08 (syst.) MeV was measured, in agreement with an earlier experiment.

nucl-ex

The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge

We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.

physics.ins-det

Development of a mini-PET Detector based on Silicon Photomultiplier Arrays for Plant Imaging Applications

A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs will allow imaging setups involving high strength MRI-type magnetic fields. The latter will allow for better position resolution of the initial positron annihilations in the plant tissue. In the present work, prototype arrays are tested for the uniformity of their response as it is known that PSPMTs require significant gain compensation on the individual channels to achieve an improved uniformity in response. The initial tests indicate a high likelihood that the SiPM arrays can be used without any gain compensation.

physics.ins-det

High Resolution Spectroscopy of 16N_Lambda by Electroproduction

An experimental study of the 16O(e,e'K^+)16N_Lambda reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e,e'K^+)Lambda,Sigma_0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 +/- 0.16 MeV was obtained for 16N_Lambda with better precision than previous measurements on the mirror hypernucleus 16O_Lambda. Precise energies have been determined for peaks arising from a Lambda in s and p orbits coupled to the p_{1/2} and p_{3/2} hole states of the 15N core nucleus.

nucl-ex

High Resolution Spectroscopy of 12B_Lambda by Electroproduction

An experiment measuring electroproduction of hypernuclei has been performed in Hall A at Jefferson Lab on a $^{12}$C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has been achieved. Thus, the observed \lam{12}{B} spectrum shows for the first time identifiable strength in the core-excited region between the ground-state {\it s}-wave $Λ$ peak and the 11 MeV {\it p}-wave $Λ$ peak.

nucl-ex

Time resolution of Burle 85001 micro-channel plate photo-multipliers in comparison with Hamamatsu R2083

The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing characteristics of the micro-channel plate photo-multiplier 85001 from Burle, which can be operated in a high magnetic field environment. For reference and comparison, measurements were also made using the standard PMT R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters 2cmx3cmx50cm with PMs at the ends, yields 59.1(0.7)ps. The location method of particles from radiative source with known coordiantes has been used to compare timing resolutions of R2083 and Burle-85001.This ``coordinate method'' requires only one counter instrumented with two PMs and it yields 59.5(0.7)ps. For the micro-channel plate photomultiplier from Burle with an external amplification of 10 to the signals, the coordinate method yields 130(4)ps. This method also makes it possible to estimate the number of primary photo-electrons.

nucl-ex