SearcharxivSearch

arXiv subjects

CMS HGCAL collaboration

Publications and source records attributed to CMS HGCAL collaboration.

2 recordsLinked to original sources

Leakage current of high-fluence neutron-irradiated 8" silicon sensors for the CMS Endcap Calorimeter Upgrade

The HL-LHC will challenge the detectors with a nearly 10-fold increase in integrated luminosity compared to the previous LHC runs combined, thus the CMS detector will be upgraded to face the higher levels of radiation and the larger amounts of collision data to be collected. The High-Granularity Calorimeter will replace the current endcap calorimeters of the CMS detector. It will facilitate the use of particle-flow calorimetry with its unprecedented transverse and longitudinal readout/trigger segmentation, with more than 6M readout channels. The electromagnetic section as well as the high-radiation regions of the hadronic section of the HGCAL (fluences above $10^{14}~n_{eq.}/cm^{2}$) will be equipped with silicon pad sensors, covering a total area of 620 m$^2$. Fluences up to $10^{16}~n_{eq.}/cm^{2}$ and doses up to 1.5 MGy are expected. The sensors are processed on novel 8" p-type wafers with an active thickness of 300 $\mu{}m$, 200 $\mu{}m$ and 120 $\mu{}m$ and cut into hexagonal shapes for optimal use of the wafer area and tiling. Each sensor contains several hundred individually read out cells of two sizes (around 0.6 cm$^2$ or 1.2 cm$^2$). To investigate the radiation-induced bulk damage, the sensors have been irradiated with neutrons at RINSC to fluences between $6.5 \times 10^{14}~n_{eq.}/cm^{2}$ and $1.4 \times 10^{16}~n_{eq.}/cm^{2}$. Electrical characterization results are presented for full sensors, as well as for partial sensors cut from multi-geometry wafers with internal dicing lines on the HV potential within the active sensor area. Leakage current behaviour is investigated for various sensor types and fluence levels, including its temperature dependence. Finally, methods to limit the annealing time of the sensors during irradiation are investigated by analysing the impact of splitting high-fluence irradiations.

physics.ins-det

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration, reconstruction and evaluation of the timing capabilities of the CMS HGCAL prototype in the beam tests in 2018. The calibration procedure includes multiple steps and corrections ranging from tens of nanoseconds to a few hundred picoseconds. The timing performance is studied using signals from positron beam particles with energies between 20 GeV and 300 GeV. The performance is studied as a function of particle energy against an external timing reference as well as standalone by comparing the two different halves of the prototype. The timing resolution is found to be 60 ps for single-channel measurements and better than 20 ps for full showers at the highest energies, setting excellent perspectives for the HGCAL calorimeter performance at the HL-LHC.

physics.ins-det