SearcharxivSearch

arXiv subjects

Cameron Deans

Publications and source records attributed to Cameron Deans.

14 recordsLinked to original sources

Design and implementation of a modular laser system for AMO experiments

Robust laser delivery and stabilization are key components in atom-based quantum technologies, such as quantum computing. Moving these technologies towards product-like deployment requires scalable, compact, cost-effective, and upgradable modules. Here we describe laser systems consisting of application-flexible modules and demonstrate their performance by characterizing key metrics and by integration with ion trap systems. The laser system is confined to a single server rack and a compact locking station. Both are Class 1 laser products with fiber in-out and electronic control of the laser light. This is achieved through precision manufacture of optical boards that are designed to reduce the degrees of freedom, ease alignment, and increase the robustness to environmental factors. We present a range of 13 wavelengths from 375 nm to 1092 nm: efficiencies from laser source to ion trap range from 21 - 28%, with laser stabilization line widths below 1 MHz.

physics.atom-ph

A Comparison of Calcium Sources for Ion-Trap Loading via Laser Ablation

Trapped-ion technology is a leading approach for scalable quantum computing. A key element of ion trapping is reliable loading of atomic sources into the trap. While thermal atomic ovens have traditionally been used for this purpose, laser ablation has emerged as a viable alternative in recent years, offering the advantages of faster and more localized loading with lower heat dissipation. Calcium is a well-established ion for qubit applications. Here we examine a range of calcium sources for ablation and provide a comprehensive analysis of each. We consider factors such as ease of use, temperature and yield of the ablation plume, and the lifetime of ablation spots. For each target, we estimate the number of trappable atoms per ablation pulse for a typical surface and 3D ion trap.

physics.atom-ph

Electromagnetic induction imaging with a scanning radio-frequency atomic magnetometer

We demonstrate electromagnetic induction imaging with an unshielded, portable radio-frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head and on the active compensation of the ambient magnetic field. Additionally, a procedure is implemented to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in suppressing the detrimental effects of the spatial variation of the magnetic environment.

physics.atom-ph

Sub-Sm$^{-1}$ electromagnetic induction imaging with an unshielded atomic magnetometer

Progress in electromagnetic induction imaging with atomic magnetometers has brought its domain to the edge of the regime useful for biomedical imaging. However, a demonstration of imaging below the required 1 Sm$^{-1}$ level is still missing. In this Letter, we use an $^{87}$Rb radio-frequency atomic magnetometer operating near room temperature in an unshielded environment to image calibrated solutions mimicking the electric conductivity of live tissues. By combining the recently introduced near-resonant imaging technique with a dual radio-frequency coil excitation scheme, we image 5 mL of solutions down to 0.9 Sm$^{-1}$. We measure a signal-to-noise ratio of 2.7 at 2 MHz for 0.9 Sm$^{-1}$, increased up to 7.2 with offline averaging. Our work is an improvement of 50 times on previous imaging results, and demonstrates the sensitivity and stability in unshielded environments required for imaging biological tissues, in particular for the human heart.

physics.ins-det

Electromagnetic induction imaging with atomic magnetometers: unlocking the low-conductivity regime

Electromagnetic induction imaging with atomic magnetometers has disclosed unprecedented domains for imaging, from security screening to material characterization. However, applications to low-conductivity specimens -- most notably for biomedical imaging -- require sensitivity, stability, and tunability only speculated thus far. Here, we demonstrate contactless and non-invasive imaging down to 50 S/m using a 50 fT/Hz$^{-1/2}$ $^{87}$Rb radio-frequency atomic magnetometer operating in an unshielded environment and near room temperature. Two-dimensional images of test objects are obtained with a near-resonant imaging approach, which reduces the phase noise by a factor 172, with projected sensitivity of 1 S/m. Our results, an improvement of more than three orders of magnitude on previous imaging demonstrations, push electromagnetic imaging with atomic magnetometers to regions of interest for semiconductors, insulators, and biological tissues.

physics.atom-ph

A Cold Atom Radio-Frequency Magnetometer

We propose and demonstrate a radio-frequency atomic magnetometer with sub-Doppler laser cooled rubidium-87. With a simple and compact design, our system demonstrates a sensitivity of $330~pT/\sqrt{Hz}$ in an unshielded environment, thus matching or surpassing previously reported cold atoms designs. By merging the multiple uses and robustness of radio-frequency atomic magnetometers with the detailed control of laser cooling, our cold atom radio-frequency magnetometer has the potential to move applications of atomic magnetometry to high spatial resolution. Direct impact in metrology for applied sciences, materials characterization, and nanotechnology can be anticipated.

physics.atom-ph

Sub-picotesla widely tunable atomic magnetometer operating at room-temperature in unshielded environments

We report on a single-channel rubidium radio-frequency atomic magnetometer operating in un-shielded environments and near room temperature with a measured sensitivity of 130 fT/\sqrt{Hz}. We demonstrate consistent, narrow-bandwidth operation across the kHz - MHz band, corresponding to three orders of magnitude of magnetic field amplitude. A compensation coil system controlled by a feedback loop actively and automatically stabilizes the magnetic field around the sensor. We measure a reduction of the 50 Hz noise contribution by an order of magnitude. The small effective sensor volume, 57 mm^3, increases the spatial resolution of the measurements. Low temperature operation, without any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically extends the range of potential field applications for our device.

physics.atom-ph

Non-destructive structural imaging of steelwork with atomic magnetometers

We demonstrate the imaging of ferromagnetic carbon steel samples and we detect the thinning of their profile with a sensitivity of 0.1 mm using a Cs radio-frequency atomic magnetometer. Images are obtained at room temperature, in magnetically unscreened environments. By using a dedicated arrangement of the setup and active compensation of background fields, the magnetic disturbance created by the samples' magnetization is compensated. Proof-of-concept demonstrations of non-destructive structural evaluation in the presence of concealing conductive barriers are also provided. The relevant impact for steelwork inspection and health and usage monitoring without disruption of operation is envisaged, with direct benefit for industry, from welding in construction to pipeline inspection and corrosion under insulation in the energy sector.

physics.ins-det

Active Underwater Detection with an Array of Atomic Magnetometers

We report on a 2x2 array of radio-frequency atomic magnetometers in magnetic induction tomography configuration. Active detection, localization, and real-time tracking of conductive, non-magnetic targets are demonstrated in air and saline water. Penetration in different media and detection are achieved thanks to the sensitivity and tunability of the sensors, and to the active nature of magnetic induction probing. We obtained a 100% success rate for automatic detection and 93% success rate for automatic localization in air and water, up to 190 mm away from the sensors' plane (100 mm underwater). We anticipate magnetic induction tomography with arrays of atomic magnetometers finding applications in civil engineering and maintenance, oil&gas industry, geological surveys, marine science, archeology, search and rescue, and security and surveillance.

physics.ins-det

Machine learning based localization and classification with atomic magnetometers

We demonstrate identification of position, material, orientation and shape of objects imaged by an $^{85}$Rb atomic magnetometer performing electromagnetic induction imaging supported by machine learning. Machine learning maximizes the information extracted from the images created by the magnetometer, demonstrating the use of hidden data. Localization 2.6 times better than the spatial resolution of the imaging system and successful classification up to 97$\%$ are obtained. This circumvents the need of solving the inverse problem, and demonstrates the extension of machine learning to diffusive systems such as low-frequency electrodynamics in media. Automated collection of task-relevant information from quantum-based electromagnetic imaging will have a relevant impact from biomedicine to security.

physics.atom-ph

Remote detection of rotating machinery with a portable atomic magnetometer

We demonstrate remote detection of rotating machinery, using an atomic magnetometer at room temperature and in an unshielded environment. The system relies on the coupling of the AC magnetic signature of the target with the spin-polarized, precessing atomic vapor of a radio-frequency optical atomic magnetometer. The AC magnetic signatures of rotating equipment or electric motors appear as sidebands in the power spectrum of the atomic sensor, which can be tuned to avoid noisy bands that would otherwise hamper detection. A portable apparatus is implemented and experimentally tested. Proof-of-concept investigations are performed with test targets mimicking possible applications, and the operational conditions for optimum detection are determined. Our instrument provides comparable or better performance than a commercial fluxgate and allows detection of rotating machinery behind a wall. These results demonstrate the potential for ultrasensitive devices for remote industrial and usage monitoring, security, and surveillance.

physics.ins-det

Electromagnetic Imaging with Atomic Magnetometers: A Novel Approach to Security and Surveillance

We describe our research programme on the use of atomic magnetometers to detect conductive objects via electromagnetic induction. The extreme sensitivity of atomic magnetometers at low frequencies, up to seven orders of magnitude higher than a coil-based system, permits deep penetration through different media and barriers, and in various operative environments. This eliminates the limitations usually associated with electromagnetic detection.

physics.atom-ph

Optical atomic magnetometry for magnetic induction tomography of the heart

We report on the use of radio-frequency optical atomic magnetometers for magnetic induction tomography measurements. We demonstrate the imaging of dummy targets of varying conductivities placed in the proximity of the sensor, in an unshielded environment at room-temperature and without background subtraction. The images produced by the system accurately reproduce the characteristics of the actual objects. Furthermore, we perform finite element simulations in order to assess the potential for measuring low-conductivity biological tissues with our system. Our results demonstrate the feasibility of an instrument based on optical atomic magnetometers for magnetic induction tomography imaging of biological samples, in particular for mapping anomalous conductivity in the heart.

physics.atom-ph

Electromagnetic induction imaging with a radio-frequency atomic magnetometer

We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

physics.atom-ph