Searcharxiv⌕ Search

arXiv subjects

Carlo Ferrigno

Publications and source records attributed to Carlo Ferrigno.

58 records · Page 4Linked to original sources

High variability in Vela X-1: giant flares and off states

We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates that there appear to be two types of flares: relatively brief flares, which can be extremely intense and show spectral softening, in contrast to high intensity states, which are longer and show no softening. Both flares and off states are interpreted as being due to a strongly structured wind of the optical companion. When Vela X-1 encounters a cavity with strongly reduced density, the flux will drop triggering the onset of the propeller effect, which inhibits further accretion, giving rise to off states. The sudden decrease in the density of the material required to trigger the propeller effect in Vela X-1 is of the same order as predicted by theoretical papers about the densities in OB star winds. A similarly structured wind can produce giant flares when Vela X-1 encounters a dense blob in the wind.

astro-ph↗

INTEGRAL observation of the accreting pulsar 1E1145.1-6141

We analyze 1050 ks of INTEGRAL data of the high mass X-ray binary pulsar 1E 1145.1-6141 to study its properties over a long time baseline, from June 2003 to June 2004, with wide spectral coverage. We study three high luminosity episodes, two of them at the system apoastron, three brightening with lower intensity, two at the periastron, and one extended period of intermediate luminosity spanning one orbital cycle. We perform timing analysis to determine the pulse period and pulse profiles at different energy ranges. We also analyze the broad band phase average spectrum of different luminosity states and perform phase resolved spectroscopy for the first flare. From the timing analysis, we find a pulse period of ~297 s around MJD 53000 with a significant scatter around the mean value. From the spectral analysis we find that the source emission can be described by an absorbed bremsstrahlung model in which the electron temperature varies between ~25 and ~37 keV, without any correlation to luminosity, and the intrinsic absorbing column is constantly of the order of 10^23 cm^-2. Phase resolved spectral analysis evidences a different temperature of the plasma in the ascending and descending edges of the pulse during the first flare. This justifies the pulse maximum shift by ~0.4 phase units between 20 and 100 keV observed in the pulse profiles. The comparison with the previous period measurements reveals that the source is currently spinning-down, in contrast to the long term secular trend observed so far indicating that at least a temporary accretion disk is formed. The study of the spectral property variations with respect to time and spin phase suggests the presence of two emitting components at different temperatures whose relative intensity varies with time.

astro-ph↗

INTEGRAL observation of the accreting pulsar GX 1+4

We present the results of the INTEGRAL monitoring campaign on the accreting low mass X-ray binary pulsar GX 1+4 performed during the Galactic plane scan of the INTEGRAL Core Programme. The source was observed in different luminosity states ranging from L(20-40 keV)= 1.7x10^{-10} erg/cm^2/s, to L(20-40 keV)=10.5x10^{-10} erg/cm^2/s for about 779 ks from March 2003 until October 2004. Our observations confirm the secular spin down of GX 1+4 with the spin-period varying from 139.63 s to 141.56 s. In the highest luminosity state a spin-up phase is observed. The phase-averaged spectrum of the source was modelled either with an absorbed cut-off power law or with a Comptonization model with significantly different parameters in the two brightest luminosity states. No evidence for any absorption-like feature is observed in the phase-averaged spectrum up to 110 keV. At highest luminosity, the source is found to pulsate up to 130 keV. Phase-resolved spectroscopy reveals a phase-dependent continuum and marginal evidence of an absorption feature at 34 keV in the descending part of the pulse. If interpreted as due to electron resonant cyclotron scattering, the magnetic field in the emitting region would be 2.9x10^{12}(1+z) G where z is the gravitational red shift of the emitting region. We also observed a very low luminosity state typical of this source, which lasted for about two days during which the source spectrum was modelled by a simple power-law and a pulsed signal was still detectable in the 15-100 keV energy range.

astro-ph↗

High Resolution X-ray Spectroscopic Constraints on Cooling-Flow Models

We present XMM-Newton Reflection Grating Spectrometer observations of X-ray clusters and groups of galaxies. We demonstrate the failure of the standard cooling-flow model to describe the soft X-ray spectrum of clusters of galaxies. We also emphasize several new developments in the study of the soft X-ray spectrum of cooling flows. Although there is some uncertainty in the expected mass deposition rate for any individual cluster, we show that high resolution RGS spectra robustly demonstrate that the expected line emission from the isobaric cooling-flow model is absent below 1/3 of the background temperature rather than below a fixed temperature in all clusters. Furthermore, we demonstrate that the best-resolved cluster spectra are inconsistent with the predicted shape of the differential luminosity distribution and the measured distribution is tilted to higher temperatures. These observations create several fine-tuning challenges for current theoretical explanations for the soft X-ray cooling-flow problem. Comparisons between these observations and other X-ray measurements are discussed.

astro-ph↗