Searcharxiv⌕ Search

arXiv subjects

Carol Yan Yan Chan

Publications and source records attributed to Carol Yan Yan Chan.

4 recordsLinked to original sources

Improved Constraints on Cosmic Microwave Background Circular Polarization with CLASS

We present improved constraints on circular polarization in the cosmic microwave background (CMB) from the Cosmology Large Angular Scale Surveyor (CLASS) experiment using data at 90, 150, and 220 GHz to complement previous results based on 40 GHz data alone. We extend constraints on circular polarization from the atmosphere to all CLASS frequencies and compare with a model of the atmospheric circular polarization spectrum. The inclusion of data at all CLASS frequencies improves upper limits on circular polarization, Stokes $V$, in the CMB by a factor of $\sim 5$ at the largest angular scales ($10 < \ell < 30$) and extends the constraints to smaller angular scales, $\ell = 700$. In combination with Planck temperature data, we provide the first limits on the temperature-circular-polarization ($TV$) power spectrum to date. Both circular polarization ($VV$) and $TV$ power spectra are consistent with zero, and CLASS places upper limits of $5.4 \times 10^{-3}$ $μ$K$_{\text{CMB}}^2$ on $VV$ at large angular scale ($10 < \ell < 30$) and $5.8 \times 10^{-1}$ $μ$K$_{\text{CMB}}^2$ on $TV$ at 95% confidence at $30 < \ell < 50$.

astro-ph.CO↗

Detectors for CLASS-W2: The second 90 GHz telescope of the Cosmology Large Angular Scale Surveyor

The Cosmology Large Angular Scale Surveyor (CLASS) is measuring the Cosmic Microwave Background (CMB) polarization anisotropy on the largest angular scales (>1 degree) to probe the epochs of inflation and reionization. To enhance the CMB mapping speed, we have built, tested, and commissioned in August 2025 a second 90 GHz receiver (CLASS-W2) with a detector focal plane composed of feedhorn-coupled Transition Edge Sensor (TES) bolometers fabricated at NIST-Boulder. The focal plane consists of four modules, each containing 37 feedhorns coupling orthogonal polarizations onto two TES bolometers, for a total of 296 optically sensitive detectors. Laboratory tests show highly uniform TES properties with an array average critical temperature of 184+-3 mK, a thermal conductance of 460+-47 pW/K, and a normal resistance of 7.8+-0.3 mOhms. The detector array has an average band center frequency of 95.2 GHz with 28.3 GHz bandwidth, and achieves a detector yield of 94%. On-sky measurements indicate a mean detector optical load of 3.3 pW, corresponding to an antenna temperature of ~23 K. The array's average beam solid angle is 124 $μ$sr, with a full width at half maximum of 0.592 degrees, and the end-to-end average optical efficiency is 0.37. We find that high-frequency 'blue-leak' radiation couples directly to the TES bolometer islands; adding a metal-mesh low-pass filter with cutoff frequency of 157 GHz in front of the focal plane suppresses the 'blue-leak' power by 0.9 pW. The four-module array achieves a noise-equivalent temperature of NET= 16 uKrtS. Adding this array has boosted the CLASS 90 GHz mapping speed by 41%.

astro-ph.IM↗

Diamond-loaded polyimide aerogel scattering filters and their applications in astrophysical and planetary science observations

Infrared-blocking, aerogel-based scattering filters have a broad range of potential applications in astrophysics and planetary science instruments in the far-infrared, sub-millimeter, and microwave regimes. This paper demonstrates the ability of conductively-loaded, polyimide aerogel filters to meet the mechanical and science instrument requirements for several experiments, including the Cosmology Large Angular Scale Surveyor (CLASS), the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), and the Sub-millimeter Solar Observation Lunar Volatiles Experiment (SSOLVE). Thermal multi-physics simulations of the filters predict their performance when integrated into a cryogenic receiver. Prototype filters have survived cryogenic cycling to 4\,K with no degradation in mechanical properties. Measurement of total hemispherical reflectance and transmittance, as well as cryogenic tests of the aerogel filters in a full receiver context, allow estimates of the integrated infrared emissivity of the filters. Knowledge of the emissivity will help instrument designers incorporate the filters into future experiments in planetary science, astrophysics, and cosmology.

astro-ph.IM↗

Design and characterization of a 60-cm reflective half-wave plate for the CLASS 90 GHz band telescope

Front-end polarization modulation enables improved polarization measurement stability by modulating the targeted signal above the low-frequency $1/f$ drifts associated with atmospheric and instrumental instabilities and diminishes the impact of instrumental polarization. In this work, we present the design and characterization of a new 60-cm diameter Reflective Half-Wave Plate (RHWP) polarization modulator for the 90 GHz band telescope of the Cosmology Large Angular Scale Surveyor (CLASS) project. The RHWP consists of an array of parallel wires (diameter $50~\mathrm{μm}$, $175~\mathrm{μm}$ pitch) positioned $0.88~\mathrm{mm}$ from an aluminum mirror. In lab tests, it was confirmed that the wire resonance frequency ($f_\mathrm{res}$) profile is consistent with the target, $139~\mathrm{Hz}<f_\mathrm{res}<154~\mathrm{Hz}$ in the optically active region (diameter smaller than $150~\mathrm{mm}$), preventing the wire vibration during operation and reducing the RHWP deformation under the wire tension. The mirror tilt relative to the rotating axis was controlled to be $<15''$, corresponding to an increase in beam width due to beam smearing of $<0.6''$, negligible compared to the beam's full-width half-maximum of $36'$. The median and 16/84th percentile of the wire--mirror separation residual was $0.048^{+0.013}_{-0.014}~\mathrm{mm}$ in the optically active region, achieving a modulation efficiency $ε=96.2_{+0.5}^{-0.4}\%$ with an estimated bandpass of 34 GHz. The angular velocity of the RHWP was maintained to an accuracy of within $0.005\%$ at the nominal rotation frequency ($2.5~\mathrm{Hz}$). The RHWP has been successfully integrated into the CLASS 90 GHz telescope and started taking data in June 2024, replacing the previous modulator that has been in operation since June 2018.

astro-ph.IM↗