Searcharxiv⌕ Search

arXiv subjects

Carolanne V. M. Vouriot

Publications and source records attributed to Carolanne V. M. Vouriot.

2 recordsLinked to original sources

Robustness of point measurements of carbon dioxide concentration for the inference of ventilation rates in a wintertime classroom

Indoor air quality in schools and classrooms is paramount for the health and well-being of pupils and staff. CO2 monitors offer a cost-effective way to assess and manage ventilation provision. However, often only a single point measurement is available which might not be representative of the CO2 distribution within the room. A relatively generic UK classroom in wintertime is simulated using CFD. The natural ventilation provision is driven by buoyancy through high- and low-level openings in both an opposite-ended or single-ended configuration, in which only the horizontal location of the high-level vent is modified. CO2 is modelled as a passive scalar and is shown not to be `well-mixed' within the space. Perhaps surprisingly, the single-ended configuration leads to a `more efficient' ventilation, with lower average CO2 concentration. Measurements taken near the walls, often the location of CO2 monitors, are compared with those made throughout the classroom and found to be more representative of the ventilation rate if made above the breathing zone. These findings are robust with respect to ventilation flow rates and to the flow patterns observed, which were tested by varying the effective vent areas and the ratio of the vent areas.

physics.flu-dyn↗

Uniformly distributed floor sources of buoyancy can give rise to significant spatial inhomogeneities within rooms

Displacement ventilation, where cool external air enters a room through low-level vents and warmer air leaves through high-level vents, is characterised by vertical gradients in pressure arising from the warmer indoor temperatures. Models usually assume that horizontal variations of temperature difference are small in comparison and are, therefore, unimportant. Small-scale laboratory experiments and computational fluid dynamics were used to examine these flows, driven by a uniformly heated floor. These experiments and simulations show that the horizontal variations of temperature difference can be neglected for predictions of the bulk ventilation rate; however, they also evidence that these horizontal variations can be significant and play a critical role in establishing the pattern of flow within the room -- this renders the horizontal position of the low- and high-level vents (relative to one another) important. We consider two cases: single-ended (where inlet and outlet are at the same end of the room) and opposite-ended. In both cases the ventilation flow rate is the same. However, in the opposite-ended case a dead zone is established in the upper part of the room which results in significant horizontal variations. We consider the formation of this dead zone by examining the streamline patterns and the age of air within the room. We discuss the implications for occupant exposure to pollutants and airborne disease.

physics.flu-dyn↗