Searcharxiv⌕ Search

arXiv subjects

Caroline C. W. Klaver

Publications and source records attributed to Caroline C. W. Klaver.

5 recordsLinked to original sources

Robust retinal biometrics for patient identity verification and retrieval across age and imaging devices

Patient identity errors can compromise longitudinal medical records, research databases, and downstream clinical decisions. We present a retinal biometric system for verifying claimed identities and retrieving the correct identity from color fundus images. We trained a 512-dimensional metric-learning encoder combining a ConvNeXtV2 backbone with ArcFace and triplet losses on 227,004 images from 21,851 patient-eye identities in the Rotterdam Study, spanning multiple imaging devices and up to 32.6 years of follow-up. The system was evaluated on held-out Rotterdam Study data and externally on the UK Biobank and Age-Related Eye Disease Study (AREDS). Before evaluation, we used the model to screen for identity inconsistencies and manually adjudicated flagged images, identifying incorrect assignments in 0.588% of Rotterdam Study images, 0.259% of UK Biobank images, and 0.164% of AREDS images. In retrospective-only verification after removing near-duplicate images, the system achieved AUROCs of 0.9998, 0.9997, and 0.9998 in the Rotterdam Study, UK Biobank, and AREDS, respectively. For identity retrieval using only previously acquired images, Recall@1 was 99.7%, 97.2%, and 97.6%, respectively, from galleries averaging 4436-8510 identities; the correct identity appeared among the top five results in at least 98.6% of cases. Performance remained robust across imaging devices and long follow-up intervals, while lower image quality and inconsistent retinal fields accounted for most failures. These findings establish retinal anatomy as a durable biometric signal, useful for safeguarding the integrity of longitudinal imaging records.

cs.CV↗

retinalysis-vascx: An explainable software toolbox for the extraction of retinal vascular biomarkers

Automatic extraction of retinal vascular biomarkers from color fundus images (CFI) is crucial for large-scale studies of the retinal vasculature. We present VascX, an open-source Python toolbox that extracts biomarkers from CFI artery-vein segmentations. VascX starts from vessel segmentation masks, extracts their skeletons, builds undirected and directed vessel graphs, and resolves vessel segments into longer vessels. A comprehensive set of biomarkers is derived, including vascular density, central retinal equivalents (CREs), and tortuosity. Spatially localized biomarkers may be calculated over grids placed relative to the fovea and optic disc. VascX is released via GitHub and PyPI with comprehensive documentation and examples. Our test-retest reproducibility analysis on repeat imaging of the same eye by different devices shows that most VascX biomarkers have moderate to excellent agreement (ICC > 0.5), with important differences in the level of robustness of different biomarkers. Our analyses of biomarker sensitivity to image perturbations and heuristic parameter values support these differences and further characterize VascX biomarkers. Ultimately, VascX provides an explainable and easily modifiable feature-extraction toolbox that complements segmentation to produce reliable retinal vascular biomarkers. Our graph-based biomarker computation stages support reproducible, region-aware measurements suited for large-scale clinical and epidemiological research. By enabling easy extraction of existing biomarkers and rapid experimentation with new ones, VascX supports oculomics research. Its robustness and computational efficiency facilitate scalable deployment in large databases, while open-source distribution lowers barriers to adoption for ophthalmic researchers and clinicians.

q-bio.TO↗

Uncertainty-Aware Multiple-Instance Learning for Reliable Classification: Application to Optical Coherence Tomography

Deep learning classification models for medical image analysis often perform well on data from scanners that were used during training. However, when these models are applied to data from different vendors, their performance tends to drop substantially. Artifacts that only occur within scans from specific scanners are major causes of this poor generalizability. We aimed to improve the reliability of deep learning classification models by proposing Uncertainty-Based Instance eXclusion (UBIX). This technique, based on multiple-instance learning, reduces the effect of corrupted instances on the bag-classification by seamlessly integrating out-of-distribution (OOD) instance detection during inference. Although UBIX is generally applicable to different medical images and diverse classification tasks, we focused on staging of age-related macular degeneration in optical coherence tomography. After being trained using images from one vendor, UBIX showed a reliable behavior, with a slight decrease in performance (a decrease of the quadratic weighted kappa ($κ_w$) from 0.861 to 0.708), when applied to images from different vendors containing artifacts; while a state-of-the-art 3D neural network suffered from a significant detriment of performance ($κ_w$ from 0.852 to 0.084) on the same test set. We showed that instances with unseen artifacts can be identified with OOD detection and their contribution to the bag-level predictions can be reduced, improving reliability without the need for retraining on new data. This potentially increases the applicability of artificial intelligence models to data from other scanners than the ones for which they were developed.

eess.IV↗

Multi-modal, multi-task, multi-attention (M3) deep learning detection of reticular pseudodrusen: towards automated and accessible classification of age-related macular degeneration

Objective Reticular pseudodrusen (RPD), a key feature of age-related macular degeneration (AMD), are poorly detected by human experts on standard color fundus photography (CFP) and typically require advanced imaging modalities such as fundus autofluorescence (FAF). The objective was to develop and evaluate the performance of a novel 'M3' deep learning framework on RPD detection. Materials and Methods A deep learning framework M3 was developed to detect RPD presence accurately using CFP alone, FAF alone, or both, employing >8000 CFP-FAF image pairs obtained prospectively (Age-Related Eye Disease Study 2). The M3 framework includes multi-modal (detection from single or multiple image modalities), multi-task (training different tasks simultaneously to improve generalizability), and multi-attention (improving ensembled feature representation) operation. Performance on RPD detection was compared with state-of-the-art deep learning models and 13 ophthalmologists; performance on detection of two other AMD features (geographic atrophy and pigmentary abnormalities) was also evaluated. Results For RPD detection, M3 achieved area under receiver operating characteristic (AUROC) 0.832, 0.931, and 0.933 for CFP alone, FAF alone, and both, respectively. M3 performance on CFP was very substantially superior to human retinal specialists (median F1-score 0.644 versus 0.350). External validation (on Rotterdam Study, Netherlands) demonstrated high accuracy on CFP alone (AUROC 0.965). The M3 framework also accurately detected geographic atrophy and pigmentary abnormalities (AUROC 0.909 and 0.912, respectively), demonstrating its generalizability. Conclusion This study demonstrates the successful development, robust evaluation, and external validation of a novel deep learning framework that enables accessible, accurate, and automated AMD diagnosis and prognosis.

cs.CV↗

A deep learning model for segmentation of geographic atrophy to study its long-term natural history

Purpose: To develop and validate a deep learning model for automatic segmentation of geographic atrophy (GA) in color fundus images (CFIs) and its application to study growth rate of GA. Participants: 409 CFIs of 238 eyes with GA from the Rotterdam Study (RS) and the Blue Mountain Eye Study (BMES) for model development, and 5,379 CFIs of 625 eyes from the Age-Related Eye Disease Study (AREDS) for analysis of GA growth rate. Methods: A deep learning model based on an ensemble of encoder-decoder architectures was implemented and optimized for the segmentation of GA in CFIs. Four experienced graders delineated GA in CFIs from RS and BMES. These manual delineations were used to evaluate the segmentation model using 5-fold cross-validation. The model was further applied to CFIs from the AREDS to study the growth rate of GA. Linear regression analysis was used to study associations between structural biomarkers at baseline and GA growth rate. A general estimate of the progression of GA area over time was made by combining growth rates of all eyes with GA from the AREDS set. Results: The model obtained an average Dice coefficient of 0.72 $\pm$ 0.26 on the BMES and RS. An intraclass correlation coefficient of 0.83 was reached between the automatically estimated GA area and the graders' consensus measures. Eight automatically calculated structural biomarkers (area, filled area, convex area, convex solidity, eccentricity, roundness, foveal involvement and perimeter) were significantly associated with growth rate. Combining all growth rates indicated that GA area grows quadratically up to an area of around 12 mm$^{2}$, after which growth rate stabilizes or decreases. Conclusion: The presented deep learning model allowed for fully automatic and robust segmentation of GA in CFIs. These segmentations can be used to extract structural characteristics of GA that predict its growth rate.

eess.IV↗