SearcharxivSearch

arXiv subjects

Casey DeRoo

Publications and source records attributed to Casey DeRoo.

7 recordsLinked to original sources

Lynx2030 Science Analysis Group: Final Report

The Lynx2030 Science Analysis Group (SAG) was convened to reassess the scientific goals and technical drivers of the Lynx mission concept amid a rapidly evolving astrophysics landscape. Building on the original Lynx Concept Study, the SAG examined how recent discoveries, emerging facilities, and advances in instrumentation influence the scientific opportunities for a next-generation flagship X-ray observatory. Through focused working groups, the SAG investigated the scientific impact of enhanced capabilities: (i) improved angular resolution, (ii) broader bandpass coverage, (iii) an enhanced microcalorimeter, (iv) new capabilities and observing modes, and (v) larger fields of view. Across a broad range of topics, from the formation of the first black holes and the evolution of galaxies to the baryon cycle, compact objects, stellar explosions, multi-messenger astrophysics, and the dynamic high-energy Universe, the SAG finds that the scientific motivation for a Lynx-class observatory remains compelling and, in many areas, has significantly strengthened over the past decade, prominently through JWST's discovery of the "Little Red Dots", likely massive accreting black holes in infant galaxies whose nature is fundamentally an X-ray question. This report shows that modest extensions beyond the original Lynx design reference mission can unlock transformative science while preserving the observatory's core architecture. Powerful current and future facilities such as Roman, Rubin, JWST, SKA, ngVLA, LISA, and NewAthena highlight the unique role a high-angular-resolution, high-throughput X-ray observatory would play in the multi-wavelength and multi-messenger ecosystem of the 2030s and beyond. The findings of the Lynx2030 SAG confirm Lynx's central vision: an unprecedented view of the hot and energetic Universe, enabling discoveries that will define high-energy astrophysics in the coming decades.

astro-ph.IM

Arcus X-ray telescope performance and alignment

Arcus is a concept for a probe class mission to deliver high-resolution FUV and X-ray spectroscopy. For X-rays, it combines cost-effective silicon pore optics (SPO) with high-throughput critical-angle transmission (CAT) gratings to achieve $R> 3000$ in a bandpass from 12-50 Angstroem. We show in detail how the X-ray and the UV spectrographs (XRS and UVS) on Arcus will be aligned to each other. For XRS we present ray-tracing studies to derive performance characteristics such as the spectral resolving power and effective area, study the effect of misalignments on the performance, and conclude that most tolerances can be achieved with mechanical means alone. We also present an estimate of the expected on-orbit background.

astro-ph.IM

Metrology for Measuring Custom Periodicities on Diffraction Gratings

We present a new, inexpensive, bench-top method for measuring groove period over large areas with high mapping resolution and high measurement accuracy, dubbed the grating mapper for accurate period (GMAP). The GMAP has the ability to measure large groove period changes and non-parallel grooves, both of which cannot be measured via optical interferometry. In this paper, we detail the calibration and setup of the GMAP, and employ the instrument to measure three distinct gratings. Two of these measured gratings have customized groove patterns that prevent them from being measured via other traditional methods, such as optical interferometry. Our implementation of this tool achieves a spatial resolution of 0.1 mm$\times$0.1 mm and a period error of 1.7 nm for a 3 $μ$m size groove period.

astro-ph.IM

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. While operating the device at room temperature, we measure energy resolutions (FWHM) of 48 eV at 250 eV and 83 eV at 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

physics.ins-det

Astro2020 APC White Paper: The Early Career Perspective on the Coming Decade, Astrophysics Career Paths, and the Decadal Survey Process

In response to the need for the Astro2020 Decadal Survey to explicitly engage early career astronomers, the National Academies of Sciences, Engineering, and Medicine hosted the Early Career Astronomer and Astrophysicist Focus Session (ECFS) on October 8-9, 2018 under the auspices of Committee of Astronomy and Astrophysics. The meeting was attended by fifty six pre-tenure faculty, research scientists, postdoctoral scholars, and senior graduate students, as well as eight former decadal survey committee members, who acted as facilitators. The event was designed to educate early career astronomers about the decadal survey process, to solicit their feedback on the role that early career astronomers should play in Astro2020, and to provide a forum for the discussion of a wide range of topics regarding the astrophysics career path. This white paper presents highlights and themes that emerged during two days of discussion. In Section 1, we discuss concerns that emerged regarding the coming decade and the astrophysics career path, as well as specific recommendations from participants regarding how to address them. We have organized these concerns and suggestions into five broad themes. These include (sequentially): (1) adequately training astronomers in the statistical and computational techniques necessary in an era of "big data", (2) responses to the growth of collaborations and telescopes, (3) concerns about the adequacy of graduate and postdoctoral training, (4) the need for improvements in equity and inclusion in astronomy, and (5) smoothing and facilitating transitions between early career stages. Section 2 is focused on ideas regarding the decadal survey itself, including: incorporating early career voices, ensuring diverse input from a variety of stakeholders, and successfully and broadly disseminating the results of the survey.

astro-ph.IM

Performance Testing of a Novel Off-plane Reflection Grating and Silicon Pore Optic Spectrograph at PANTER

An X-ray spectrograph consisting of radially ruled off-plane reflection gratings and silicon pore optics was tested at the Max Planck Institute for extraterrestrial Physics PANTER X-ray test facility. The silicon pore optic (SPO) stack used is a test module for the Arcus small explorer mission, which will also feature aligned off-plane reflection gratings. This test is the first time two off-plane gratings were actively aligned to each other and with a SPO to produce an overlapped spectrum. The gratings were aligned using an active alignment module which allows for the independent manipulation of subsequent gratings to a reference grating in three degrees of freedom using picomotor actuators which are controllable external to the test chamber. We report the line spread functions of the spectrograph and the actively aligned gratings, and plans for future development.

astro-ph.IM

First results from a next-generation off-plane X-ray diffraction grating

Future NASA X-ray spectroscopy missions will require high throughput, high resolution grating spectrometers. Off-plane reflection gratings are capable of meeting the performance requirements needed to realize the scientific goals of these missions. We have identified a novel grating fabrication method that utilizes common lithographic and microfabrication techniques to produce the high fidelity groove profile necessary to achieve this performance. Application of this process has produced an initial pre-master that exhibits a radial (variable line spacing along the groove dimension), high density (>6000 grooves/mm), laminar profile. This pre-master has been tested for diffraction efficiency at the BESSY II synchrotron light facility and diffracts up to 55% of incident light into usable spectral orders. Furthermore, tests of spectral resolving power show that these gratings are capable of obtaining resolutions well above 1300 ($λ/Δλ$) with limitations due to the test apparatus, not the gratings. Obtaining these results has provided confidence that this fabrication process is capable of producing off-plane reflection gratings for the next generation of X-ray observatories.

astro-ph.IM