SearcharxivSearch

arXiv subjects

Chaoran Tu

Publications and source records attributed to Chaoran Tu.

2 recordsLinked to original sources

Vectorial probability loophole in Bell test

Exhaustively identifying all loopholes in the Bell test is demanding for interpreting the results of the relevant experiments, since any loophole if not closed can be catastrophic to our understanding of the nonlocal structure of quantum mechanics. Despite a series of recent Bell experiments that claim to be free of loopholes, a united framework with a sound base is still missing to fully recognize all potential loopholes in these experiments, as verified by a recent experiment that has pinned down a detection loophole of a new type in Bell analysis. Here, we reveal another loophole previously unknown in the Bell test through a local theory developed here on the basis of a new mathematical concept of high-dimensional vectorial probability, quantified as a vector with interesting but hidden geometry in the probability space. We show that the statistical property of the stochastic events generated for the Bell test can be well described by the local theory, and, in particular, the correlations of these events that violate Bell's theorem can be closely connected to the geometry of the vectorial probability. To close the loophole, theoretical investigations are highly recommended to search for the statistical nature of the stochastic events in quantum measurements that can distinguish the predictions of quantum mechanics and those of the local theory.

physics.gen-ph

Optimal dimensions of cone and pyramid moth-eye structures for $\mathrm{SiO}_{2}$ windows

We computationally investigate the transmission efficiency through moth-eye nanostructures that are fabricated on $\mathrm{SiO}_{2}$ windows in the wavelength range from 0.4 to 2 $\mathrm{μm}$. We investigated both truncated cones and truncated pyramids, and we varied the height, bottom width, and top width of these shapes in order to maximize the transmission efficiency. We found that there is no substantial difference in transmission between truncated cone and pyramid structures. Using the constraints from the current achievable experimental limits, a relatively uniform transmission coefficient of larger than 98.8% can be obtained from 0.4 $\mathrm{μm}$ to 2 $\mathrm{μm}$. These transmission results are only 0.4% in absolute value lower than the transmission of a structure that is not constrained by current experimental limits.

physics.optics