Characterization and Optimization of a Cryogenic Pure CsI Detector with Remarkable Light Yield and Unprecedented Energy Resolution for CLOVERS Experiment

In this study, we comprehensively characterized and optimized a cryogenic pure CsI (pCsI) detector. We utilized a {$\SI{2}{cm}\times\SI{2}{cm}\times\SI{2}{cm}$} cube crystal coupled with a HAMAMATSU R11065 photomultiplier tube, achieving a remarkable light yield of \SI{35.2}{PE/\keV_{ee}} and an unprecedented energy resolution of \SI{6.9}{\%} at {\SI{59.54}{\keV}}. Additionally, we measured the scintillation decay time of pCsI, which was significantly shorter than that of CsI(Na) at room temperature. Furthermore, we investigated the impact of temperature, surface treatment, and crystal shape on light yield. Notably, the light yield peaked at approximately \SI{20}{\K} and remained stable within the range of \SI{70}--\SI{100}{\K}. The light yield of the polished crystals was approximately 1.5 times greater than that of the ground crystals, whereas the crystal shape exhibited minimal influence on the light yield. These results are crucial for the design of the \SI{10}{\kg} pCsI detector for the future CLOVERS (Coherent eLastic neutrinO(V)-nucleus scattERing at China Spallation Neutron Source (CSNS)) experiment.`

physics.ins-det

CE$\nu$NS Experiment Proposal at CSNS

The detection and cross-section measurement of Coherent Elastic Neutrino-Nucleus Scattering (CE{\nu}NS) are vital for particle physics, astrophysics, and nuclear physics. Therefore, a new CE{\nu}NS detection experiment is proposed in China. Undoped CsI crystals, each coupled with two Photon Multiplier Tubes (PMTs), will be cooled down to 77K and placed at the China Spallation Neutron Source (CSNS) to detect the CE{\nu}NS signals produced by neutrinos from stopped pion decays happening within the Tungsten target of CSNS. Owing to the extremely high light yield of pure CsI at 77K, even though it only has a neutrino flux 60\% weaker than the COHERENT experiment, the detectable signal event rate is still expected to be 0.074/day/kg (0.053/day/kg for COHERENT). Low radioactivity materials and devices will be used to construct the detector, and strong shielding will be applied to reduce the radioactive and neutron background. Dual-PMT readout should be able to reject PMT-related background, such as Cherenkov light and PMT dark noise. With all the strategies mentioned above, we hope to reach a 5.1{\sigma} signal detection significance within six months of data taking with a 12kg CsI. This presentation will discuss the experiment's design, as well as the estimation of the signal, various kinds of background, and expected signal sensitivity.

physics.ins-det