SearcharxivSearch

arXiv subjects

Chih-Pan Wu

Publications and source records attributed to Chih-Pan Wu.

12 recordsLinked to original sources

Many-body atomic response functions of xenon and germanium for leading-order sub-GeV dark matter-electron interactions in effective field theory

Direct searches of dark matter candidates with mass energies less than 1 GeV is an active research field. The energy depositions are comparable to the scale of atomic, molecular, or condensed matter systems, therefore many-body physics plays an important role in understanding the detector's response in dark matter scattering. We present in this work a comprehensive data set of atomic response functions for xenon and germanium with 12.2 and 80 eV energy thresholds, respectively, using the (multiconfiguration) relativistic random phase approximation. This approach takes into account the relativistic, exchange, and correlation effects in one self-consistent framework, and is benchmarked successfully by photoabsorption data from thresholds to 30 keV with $\lesssim5\%$ errors. Comparisons with our previous and some other independent particle approaches in literature are made. It is also found that the spin-dependent (SD) response has significant difference from the spin-independent (SI) one such that the dark matter SD and SI interactions with electrons can be distinguished in unpolarized scattering, which is typical for direct search detectors. Finally, the exclusion limits set by current experiments are updated with our new results.

astro-ph.CO

Constraints from a many-body method on spin-independent dark matter scattering off electrons using data from germanium and xenon detectors

Scattering of light dark matter (LDM) particles with atomic electrons is studied in the context of effective field theory. Contact and long-range interactions between dark matter and an electron are both considered. A state-of-the-art many-body method is used to evaluate the spin-independent atomic ionization cross sections of LDM-electron scattering, with an estimated error about 20%. New upper limits are derived on parameter space spanned by LDM mass and effective coupling strengths using data from the CDMSlite, XENON10, XENON100, and XENON1T experiments. Comparison with existing calculations shows the importance of atomic structure. Two aspects particularly important are relativistic effect for inner-shell ionization and final-state free electron wave function which sensitively depends on the underlying atomic approaches.

hep-ph

Effect on Dark Matter Exclusion Limits from New Silicon Photoelectric Absorption Measurements

Recent breakthroughs in cryogenic silicon detector technology allow for the observation of single electron-hole pairs released via particle interactions within the target material. This implies sensitivity to energy depositions as low as the smallest band gap, which is $\sim1.2$ eV for silicon, and therefore sensitivity to eV/$c^2$-scale bosonic dark matter and to thermal dark matter at masses below 100 MeV/$c^2$. Various interaction channels that can probe the lowest currently accessible masses in direct searches are related to standard photoelectric absorption. In any of these respective dark matter signal models any uncertainty on the photoelectric absorption cross section is propagated into the resulting exclusion limit or into the significance of a potential observation. Using first-time precision measurements of the photoelectric absorption cross section in silicon recently performed at Stanford University, this article examines the importance having accurate knowledge of this parameter at low energies and cryogenic temperatures for these dark matter searches.

hep-ex

Spin-dependent dark matter-electron interactions

Detectors with low thresholds for electron recoil open a new window to direct searches of sub-GeV dark matter (DM) candidates. In the past decade, many strong limits on DM-electron interactions have been set, but most on the one which is spin-independent (SI) of both dark matter and electron spins. In this work, we study DM-atom scattering through a spin-dependent (SD) interaction at leading order (LO), using well-benchmarked, state-of-the-art atomic many-body calculations. Exclusion limits on the SD DM-electron cross section are derived with data taken from experiments with xenon and germanium detectors at leading sensitivities. In the DM mass range of 0.1 - 10 GeV, the best limits set by the XENON1T experiment: $σ_e^{\textrm{(SD)}}<10^{-41}-10^{-40}\,\textrm{cm}^2$ are comparable to the ones drawn on DM-neutron and DM-proton at slightly bigger DM masses. The detector's responses to the LO SD and SI interactions are analyzed. In nonrelativistic limit, a constant ratio between them leads to an indistinguishability of the SD and SI recoil energy spectra. Relativistic calculations however show the scaling starts to break down at a few hundreds of eV, where spin-orbit effects become sizable. We discuss the prospects of disentangling the SI and SD components in DM-electron interactions via spectral shape measurements, as well as having spin-sensitive experimental signatures without SI background.

hep-ph

Model-independent determination of the Migdal effect via photoabsorption

The Migdal effect in a dark-matter-nucleus scattering extends the direct search experiments to the sub-GeV mass region through electron ionization with sub-keV detection thresholds. In this paper, we derive a rigorous and model-independent "Migdal-photoabsorption" relation that links the sub-keV Migdal process to photoabsorption. This relation is free of theoretical uncertainties as it only requires the photoabsorption cross section as the experimental input. Validity of this relation is explicitly checked in the case of xenon with an state-of-the-arts atomic calculation that is well-benchmarked by experiments. The predictions based on this relation for xenon, argon, semiconductor silicon and germanium detectors are presented and discussed.

hep-ph

Discovery potential of multi-ton xenon detectors in neutrino electromagnetic properties

Next-generation xenon detectors with multi-ton-year exposure are powerful direct probes of dark matter candidates, in particular the favorite weakly-interacting massive particles. Coupled with the features of low thresholds and backgrounds, they are also excellent telescopes of solar neutrinos. In this paper, we study the discovery potential of ton-scale xenon detectors in electromagnetic moments of solar neutrinos. Relevant neutrino-atom scattering processes are calculated by applying a state-of-the-arts atomic many-body method--relativistic random phase approximation (RRPA). Limits on these moments are derived from existing data and estimated with future experiment specifications. With one ton-year exposure, XENON-1T can improve the effective milli-charge constraint by a factor two. With LZ and DARWIN, the projected improvement on the solar neutrino effective milli-charge(magnetic moment) is around 7(2) times smaller than the current bound. If LZ can keep the same background level and push the electron recoil threshold to 0.5 keV, the projected improvement on milli-charge(magnetic moment) is about 10(3) times smaller than the current bound.

hep-ph

Low-energy electronic recoil in xenon detectors by solar neutrinos

Low-energy electronic recoil caused by solar neutrinos in multi-ton xenon detectors is an important subject not only because it is a source of the irreducible background for direct searches of weakly-interacting massive particles (WIMPs), but also because it provides a viable way to measure the solar $pp$ and $^{7}\textrm{Be}$ neutrinos at the precision level of current standard solar model predictions. In this work we perform $\textit{ab initio}$ many-body calculations for the structure, photoionization, and neutrino-ionization of xenon. It is found that the atomic binding effect yields a sizable suppression to the neutrino-electron scattering cross section at low recoil energies. Compared with the previous calculation based on the free electron picture, our calculated event rate of electronic recoil in the same detector configuration is reduced by about $25\%$. We present in this paper the electronic recoil rate spectrum in the energy window of 100 eV - 30 keV with the standard per ton per year normalization for xenon detectors, and discuss its implication for low energy solar neutrino detection (as the signal) and WIMP search (as a source of background).

hep-ex

Atomic ionization by sterile-to-active neutrino conversion and constraints on dark matter sterile neutrinos with germanium detectors

The transition magnetic moment of a sterile-to-active neutrino conversion gives rise to not only radiative decay of a sterile neutrino, but also its non-standard interaction (NSI) with matter. For sterile neutrinos of keV-mass as dark matter candidates, their decay signals are actively searched for in cosmic X-ray spectra. In this work, we consider the NSI that leads to atomic ionization, which can be detected by direct dark matter experiments. It is found that this inelastic scattering process for a nonrelativistic sterile neutrino has a pronounced enhancement in the differential cross section at energy transfer about half of its mass, manifesting experimentally as peaks in the measurable energy spectra. The enhancement effects gradually smear out as the sterile neutrino becomes relativistic. Using data taken with germanium detectors that have fine energy resolution in keV and sub-keV regimes, constraints on sterile neutrino mass and its transition magnetic moment are derived and compared with those from astrophysical observations.

hep-ph

Electronic and nuclear contributions in sub-GeV dark matter scattering: A case study with hydrogen

Scattering of sub-GeV dark matter (DM) particles with hydrogen atoms is studied in this paper. The interactions of DM with electrons and nucleons are both included and formulated in a general framework based on nonrelativistic effective field theory. On the assumption of same dark matter coupling strengths, it is found that DM-electron interactions dominate the inelastic atomic transitions to discrete excited states and ionization continuum around the threshold regions, and DM-nucleon interactions become more important with increasing energy and dominate in elastic scattering. The conclusion should apply, qualitatively, to practical detector species so that electronic and nuclear contributions in DM scattering processes can be disentangled, while issues including binding effects and recoil mechanism in many-body systems will require further detailed calculations.

hep-ph

Constraining neutrino electromagnetic properties by germanium detectors

The electromagnetic properties of neutrinos, which are either trivial or negligible in the context of the Standard Model, can probe new physics and have significant implications in astrophysics and cosmology. The current best direct limits on the neutrino millicharges and magnetic moments are both derived from data taken with germanium detectors with low thresholds at keV levels. In this paper, we discuss in detail a robust, ab initio method: the multiconfiguration relativistic random phase approximation, that enables us to reliably understand the germanium detector response at the sub-keV level, where atomic many-body physics matters. Using existing data with sub-keV thresholds, limits on reactor antineutrino's millicharge, magnetic moment, and charge radius squared are derived. The projected sensitivities for next generation experiments are also given and discussed.

hep-ph

Constraints on millicharged neutrinos via analysis of data from atomic ionizations with germanium detectors at sub-keV sensitivities

With the advent of detectors with sub-keV sensitivities, atomic ionization has been identified as a promising avenue to probe possible neutrino electromagnetic properties. The interaction cross-sections induced by millicharged neutrinos are evaluated with the ab-initio multi-configuration relativistic random-phase approximation. There is significant enhancement at atomic binding energies compared to that when the electrons are taken as free particles. Positive signals would distinctly manifest as peaks at specific energies with known intensity ratios. Selected reactor neutrino data with germanium detectors at analysis threshold as low as 300 eV are studied. No such signatures are observed, and a combined limit on the neutrino charge fraction of | \numq | < 1.0 X 10^{-12} at 90% confidence level is derived.

hep-ph

Atomic ionization of germanium due to neutrino magnetic moments

An ab initio calculation of atomic ionization of germanium (Ge) by neutrinos was carried out in the framework of multiconfiguration relativistic random phase approximation. The main goal is to provide a more accurate cross section formula than the conventional one, which is based on the free electron approximation, for searches of neutrino magnetic moments with Ge detectors whose threshold is reaching down to the sub-keV regime. Limits derived with both methods are compared, using reactor neutrino data taken with low threshold germanium detectors.

hep-ph