A Physics-Informed Deep Learning Model for MRI Brain Motion Correction

Background: MRI is crucial for brain imaging but is highly susceptible to motion artifacts due to long acquisition times. This study introduces PI-MoCoNet, a physics-informed motion correction network that integrates spatial and k-space information to remove motion artifacts without explicit motion parameter estimation, enhancing image fidelity and diagnostic reliability. Materials and Methods: PI-MoCoNet consists of a motion detection network (U-net with spatial averaging) to identify corrupted k-space lines and a motion correction network (U-net with Swin Transformer blocks) to reconstruct motion-free images. The correction is guided by three loss functions: reconstruction (L1), perceptual (LPIPS), and data consistency (Ldc). Motion artifacts were simulated via rigid phase encoding perturbations and evaluated on IXI and MR-ART datasets against Pix2Pix, CycleGAN, and U-net using PSNR, SSIM, and NMSE. Results: PI-MoCoNet significantly improved image quality. On IXI, for minor artifacts, PSNR increased from 34.15 dB to 45.95 dB, SSIM from 0.87 to 1.00, and NMSE reduced from 0.55% to 0.04%. For moderate artifacts, PSNR improved from 30.23 dB to 42.16 dB, SSIM from 0.80 to 0.99, and NMSE from 1.32% to 0.09%. For heavy artifacts, PSNR rose from 27.99 dB to 36.01 dB, SSIM from 0.75 to 0.97, and NMSE decreased from 2.21% to 0.36%. On MR-ART, PI-MoCoNet achieved PSNR gains of ~10 dB and SSIM improvements of up to 0.20, with NMSE reductions of ~6%. Ablation studies confirmed the importance of data consistency and perceptual losses, yielding a 1 dB PSNR gain and 0.17% NMSE reduction. Conclusions: PI-MoCoNet effectively mitigates motion artifacts in brain MRI, outperforming existing methods. Its ability to integrate spatial and k-space information makes it a promising tool for clinical use in motion-prone settings. Code: https://github.com/mosaf/PI-MoCoNet.git.

cs.CV↗

A Comparative Dosimetric Study of Proton and Photon Therapy in Stereotactic Arrhythmia Radioablation for Ventricular Tachycardia

Purpose: VT is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. STAR has emerged as a non-invasive option for such patients. While photon-based STAR has shown efficacy, proton therapy offers potential advantages due to its superior dose conformity and sparing of critical OARs, including the heart itself. This study aims to investigate and compare the dosimetry between proton and photon therapy for VT, focusing on target coverage and OAR sparing. Methods: We performed a retrospective study on a cohort of 34 VT patients who received photon STAR. Proton STAR plans were generated using robust optimization in RayStation to deliver the same prescription dose of 25 Gy in a single fraction while minimizing dose to OARs. Dosimetric metrics, including D99, D95, Dmean, and D0.03cc, were extracted for critical OARs and VAS. Shapiro-Wilk tests were used to assess normality, followed by paired t-tests or Wilcoxon signed-rank tests for statistical comparisons between modalities, with Bonferroni correction applied for multiple comparisons. Results: Proton and photon plans achieved comparable target coverage, with VAS D95 of 24.1 +/- 1.2 Gy vs. 24.7 +/- 1.0 Gy (p=0.294). Proton therapy significantly reduced OAR doses, including heart Dmean (3.6 +/- 1.5 Gy vs. 5.5 +/- 2.0 Gy, p<0.001), lungs Dmean (1.6 +/- 1.5 Gy vs. 2.1 +/- 1.4 Gy, p<0.001), and esophagus Dmean (0.3 +/- 0.6 Gy vs. 1.6 +/- 1.3 Gy, p<0.001), while maintaining optimal target coverage. Conclusion: Proton therapy for STAR demonstrates significant dosimetric advantages in sparing the heart and other critical OARs compared to photon therapy for VT, while maintaining equivalent target coverage. These findings highlight the potential of proton therapy to reduce treatment-related toxicity and improve outcomes for VT patients.

physics.med-ph↗

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from LA projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for X-ray spectra measurement or paired datasets for model training. Purpose: This work aims to facilitate the clinical applications of fast and low-dose DECBCT by developing a practical solution for image reconstruction in LA-DECBCT. Methods: An inter-spectral structural similarity-based regularization was integrated into the iterative image reconstruction in LA-DECBCT. By enforcing the similarity between the DE images, LA artifacts were efficiently reduced in the reconstructed DECBCT images. The proposed method was evaluated using four physical phantoms and three digital phantoms, demonstrating its efficacy in quantitative DECBCT imaging. Conclusions: The proposed method achieves accurate image reconstruction without the need for X-ray spectra measurement for optimization or paired datasets for model training, showing great practical value in clinical implementations of LA-DECBCT.

physics.med-ph↗

Current Progress of Digital Twin Construction Using Medical Imaging

Medical imaging has played a pivotal role in advancing and refining digital twin technology, allowing for the development of highly personalized virtual models that represent human anatomy and physiological functions. A key component in constructing these digital twins is the integration of high-resolution imaging data, such as MRI, CT, PET, and ultrasound, with sophisticated computational models. Advances in medical imaging significantly enhance real-time simulation, predictive modeling, and early disease diagnosis, individualized treatment planning, ultimately boosting precision and personalized care. Although challenges persist, such as the complexity of anatomical modeling, integrating various imaging modalities, and high computational demands, recent progress in imaging and machine learning has greatly improved the precision and clinical applicability of digital twins. This review investigates the role of medical imaging in developing digital twins across organ systems. Key findings demonstrate that improvements in medical imaging have enhanced the diagnostic and therapeutic potential of digital twins beyond traditional methods, particularly in imaging accuracy, treatment effectiveness, and patient outcomes. The review also examines the technical barriers that currently limit further development of digital twin technology, despite advances in medical imaging, and outlines future research avenues aimed at overcoming these challenges to unlock the full potential of this technology in precision medicine.

physics.med-ph↗

Patient-Specific CBCT Synthesis for Real-time Tumor Tracking in Surface-guided Radiotherapy

We present a new imaging system to support real-time tumor tracking for surface-guided radiotherapy (SGRT). SGRT uses optical surface imaging (OSI) to acquire real-time surface topography images of the patient on the treatment couch. However, OSI cannot visualize internal anatomy. This study proposes an Advanced Surface Imaging (A-SI) framework to address this issue. In the proposed A-SI framework, a high-speed surface imaging camera consistently captures surface images during radiation delivery, and a CBCT imager captures single-angle X-ray projections at low frequency. The A-SI then utilizes a generative model to generate real-time volumetric images with full anatomy, referred to as Optical Surface-Derived cone beam computed tomography (OSD-CBCT), based on the real-time high-frequent surface images and the low-frequency collected single-angle X-ray projections. The generated OSD-CBCT can provide accurate tumor motion for precise radiation delivery. The A-SI framework uses a patient-specific generative model: physics-integrated consistency-refinement denoising diffusion probabilistic model (PC-DDPM). This model leverages patient-specific anatomical structures and respiratory motion patterns derived from four-dimensional CT (4DCT) during treatment planning. It then employs a geometric transformation module (GTM) to extract volumetric anatomy information from the single-angle X-ray projection. A simulation study with 22 lung cancer patients evaluated the A-SI framework supported by PC-DDPM. The results showed that the framework produced real-time OSD-CBCT with high reconstruction fidelity and precise tumor localization. This study demonstrates the potential of A-SI to enable real-time tumor tracking with minimal imaging dose, advancing SGRT for motion-associated cancers and interventional procedures.

physics.med-ph↗

Unsupervised Bayesian Generation of Synthetic CT from CBCT Using Patient-Specific Score-Based Prior

Background: Cone-beam computed tomography (CBCT) scans, performed fractionally (e.g., daily or weekly), are widely utilized for patient alignment in the image-guided radiotherapy (IGRT) process, thereby making it a potential imaging modality for the implementation of adaptive radiotherapy (ART) protocols. Nonetheless, significant artifacts and incorrect Hounsfield unit (HU) values hinder their application in quantitative tasks such as target and organ segmentations and dose calculation. Therefore, acquiring CT-quality images from the CBCT scans is essential to implement online ART in clinical settings. Purpose: This work aims to develop an unsupervised learning method using the patient-specific diffusion model for CBCT-based synthetic CT (sCT) generation to improve the image quality of CBCT. Methods: The proposed method is in an unsupervised framework that utilizes a patient-specific score-based model as the image prior alongside a customized total variation (TV) regularization to enforce coherence across different transverse slices. The score-based model is unconditionally trained using the same patient's planning CT (pCT) images to characterize the manifold of CT-quality images and capture the unique anatomical information of the specific patient. The efficacy of the proposed method was assessed on images from anatomical sites including head and neck (H&N) cancer, pancreatic cancer, and lung cancer. The performance of the proposed CBCT correction method was evaluated using quantitative metrics including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). Additionally, the proposed algorithm was benchmarked against two other unsupervised diffusion model-based CBCT correction algorithms.

physics.med-ph↗

Adaptive Proton Therapy Using CBCT-Guided Digital Twins

This study aims to develop a digital twin (DT) framework to enhance adaptive proton stereotactic body radiation therapy (SBRT) for prostate cancer. Prostate SBRT has emerged as a leading option for external beam radiotherapy due to its effectiveness and reduced treatment duration. However, interfractional anatomy variations can impact treatment outcomes. This study seeks to address these uncertainties using DT concept, with the goal of improving treatment quality, potentially revolutionizing prostate radiotherapy to offer personalized treatment solutions. Our study presented a pioneering approach that leverages DT technology to enhance adaptive proton SBRT. The framework improves treatment plans by utilizing patient-specific CTV setup uncertainty, which is usually smaller than conventional clinical setups. This research contributes to the ongoing efforts to enhance the efficiency and efficacy of prostate radiotherapy, with ultimate goals of improving patient outcomes and life quality.

physics.med-ph↗

Fast MRI Reconstruction Using Deep Learning-based Compressed Sensing: A Systematic Review

Magnetic resonance imaging (MRI) has revolutionized medical imaging, providing a non-invasive and highly detailed look into the human body. However, the long acquisition times of MRI present challenges, causing patient discomfort, motion artifacts, and limiting real-time applications. To address these challenges, researchers are exploring various techniques to reduce acquisition time and improve the overall efficiency of MRI. One such technique is compressed sensing (CS), which reduces data acquisition by leveraging image sparsity in transformed spaces. In recent years, deep learning (DL) has been integrated with CS-MRI, leading to a new framework that has seen remarkable growth. DL-based CS-MRI approaches are proving to be highly effective in accelerating MR imaging without compromising image quality. This review comprehensively examines DL-based CS-MRI techniques, focusing on their role in increasing MR imaging speed. We provide a detailed analysis of each category of DL-based CS-MRI including end-to-end, unroll optimization, self-supervised, and federated learning. Our systematic review highlights significant contributions and underscores the exciting potential of DL in CS-MRI. Additionally, our systematic review efficiently summarizes key results and trends in DL-based CS-MRI including quantitative metrics, the dataset used, acceleration factors, and the progress of and research interest in DL techniques over time. Finally, we discuss potential future directions and the importance of DL-based CS-MRI in the advancement of medical imaging. To facilitate further research in this area, we provide a GitHub repository that includes up-to-date DL-based CS-MRI publications and publicly available datasets - https://github.com/mosaf/Awesome-DL-based-CS-MRI.

physics.med-ph↗

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

eess.IV↗

Dual-Energy Cone-Beam CT Using Two Complementary Limited-Angle Scans with A Projection-Consistent Diffusion Model

Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT) has been hindered by the requirement of sophisticated hardware components. Purpose: In this work, we aim to propose a practical solution for single-scan dual-energy imaging on current CBCT scanners without hardware modifications, using two complementary limited-angle scans with a projection-consistent diffusion model. Methods: Our approach has two major components: data acquisition using two complementary limited-angle scans, and dual-energy projections restoration with subsequent FDK reconstruction. Two complementary scans at different kVps are performed in a single rotation by switching the tube voltage at the middle of the source trajectory, acquiring the mixed-spectra projection in a single CBCT scan. Full-sampled dual-energy projections are then restored by a projection-consistent diffusion model in a slice-by-slice manner, followed by the DE-CBCT reconstruction using the FDK algorithm. Results: The proposed method was evaluated in a simulation study of digital abdomen phantoms and a study of real rat data. In the simulation study, the proposed method produced DE-CBCT images at a mean absolute error (MAE) of 20 HU. In the small-animal study, reconstructed DE-CBCT images using the proposed method gave an MAE of 25 HU. Conclusion: This study demonstrates the feasibility of DE-CBCT imaging using two complementary limited-angle scans with a projection-consistent diffusion model in both half-fan and short scans. The proposed method may allow quantitative applications of DE-CBCT and enable DE-CBCT-based adaptive proton therapy.

physics.med-ph↗

Image-Domain Material Decomposition for Dual-energy CT using Unsupervised Learning with Data-fidelity Loss

Background: Dual-energy CT (DECT) and material decomposition play vital roles in quantitative medical imaging. However, the decomposition process may suffer from significant noise amplification, leading to severely degraded image signal-to-noise ratios (SNRs). While existing iterative algorithms perform noise suppression using different image priors, these heuristic image priors cannot accurately represent the features of the target image manifold. Although deep learning-based decomposition methods have been reported, these methods are in the supervised-learning framework requiring paired data for training, which is not readily available in clinical settings. Purpose: This work aims to develop an unsupervised-learning framework with data-measurement consistency for image-domain material decomposition in DECT.

physics.med-ph↗

Artificial Intelligence-based Motion Tracking in Cancer Radiotherapy: A Review

Radiotherapy aims to deliver a prescribed dose to the tumor while sparing neighboring organs at risk (OARs). Increasingly complex treatment techniques such as volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), and proton therapy have been developed to deliver doses more precisely to the target. While such technologies have improved dose delivery, the implementation of intra-fraction motion management to verify tumor position at the time of treatment has become increasingly relevant. Recently, artificial intelligence (AI) has demonstrated great potential for real-time tracking of tumors during treatment. However, AI-based motion management faces several challenges including bias in training data, poor transparency, difficult data collection, complex workflows and quality assurance, and limited sample sizes. This review serves to present the AI algorithms used for chest, abdomen, and pelvic tumor motion management/tracking for radiotherapy and provide a literature summary on the topic. We will also discuss the limitations of these algorithms and propose potential improvements.

physics.med-ph↗

Streamlined Pin-Ridge-Filter Design for Single-energy Proton FLASH Planning

Purpose: This study explored the feasibility of a streamlined pin-shaped ridge filter (pin-RF) design for single-energy proton FLASH planning. Methods: An inverse planning framework integrated within a TPS was established for FLASH planning. The framework involves generating a IMPT plan based on downstream energy modulation strategy (IMPT-DS), followed by a nested spot reduction process to iteratively reduce the total number of pencil beam directions (PBDs) and energy layers along each PBD for the IMPT-DS plan. The IMPT-DS plan is then translated into the pin-RFs for a single-energy IMPT plan (IMPT-RF). The framework was validated on three lung cases, quantifying the FLASH dose of the IMPT-RF plan using the FLASH effectiveness model and comparing it with the reference dose of a conventional IMPT plan to assess the clinical benefit of the FLASH planning technique. Results: The IMPT-RF plans closely matched the corresponding IMPT-DS plans in high dose conformity, with minimal changes in V7Gy and V7.4Gy for the lung (< 5%) and small increases in Dmax for other OARs (< 3.2 Gy). Comparing the FLASH doses to the doses of corresponding IMPT-RF plans, drastic reductions of up to ~33% were observed in Dmax for OARs in the high-to-moderate-dose regions with negligible changes in Dmax for OARs in low-dose regions. Positive clinical benefits were observed with notable reductions of 18.4-33.0% in Dmax for OARs in the high-dose regions. However, in the moderate-to-low-dose regions, only marginal positive or even negative clinical benefit for OARs were observed, such as increased lung V7Gy and V7.4Gy (16.4-38.9%). Conclusions: A streamlined pin-RF design for single-energy proton FLASH planning was validated, revealing positive clinical benefits for OARs in the high dose regions. The coarsened design of the pin-RF demonstrates potential cost efficiency and efficient production.

physics.med-ph↗

Synthetic CT Generation from MRI using 3D Transformer-based Denoising Diffusion Model

Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning by eliminating the need for CT simulation and error-prone image registration, ultimately reducing patient radiation dose and setup uncertainty. We propose an MRI-to-CT transformer-based denoising diffusion probabilistic model (MC-DDPM) to transform MRI into high-quality sCT to facilitate radiation treatment planning. MC-DDPM implements diffusion processes with a shifted-window transformer network to generate sCT from MRI. The proposed model consists of two processes: a forward process which adds Gaussian noise to real CT scans, and a reverse process in which a shifted-window transformer V-net (Swin-Vnet) denoises the noisy CT scans conditioned on the MRI from the same patient to produce noise-free CT scans. With an optimally trained Swin-Vnet, the reverse diffusion process was used to generate sCT scans matching MRI anatomy. We evaluated the proposed method by generating sCT from MRI on a brain dataset and a prostate dataset. Qualitative evaluation was performed using the mean absolute error (MAE) of Hounsfield unit (HU), peak signal to noise ratio (PSNR), multi-scale Structure Similarity index (MS-SSIM) and normalized cross correlation (NCC) indexes between ground truth CTs and sCTs. MC-DDPM generated brain sCTs with state-of-the-art quantitative results with MAE 43.317 HU, PSNR 27.046 dB, SSIM 0.965, and NCC 0.983. For the prostate dataset, MC-DDPM achieved MAE 59.953 HU, PSNR 26.920 dB, SSIM 0.849, and NCC 0.948. In conclusion, we have developed and validated a novel approach for generating CT images from routine MRIs using a transformer-based DDPM. This model effectively captures the complex relationship between CT and MRI images, allowing for robust and high-quality synthetic CT (sCT) images to be generated in minutes.

eess.IV↗

Data-Driven Volumetric Image Generation from Surface Structures using a Patient-Specific Deep Leaning Model

The advent of computed tomography significantly improves patient health regarding diagnosis, prognosis, and treatment planning and verification. However, tomographic imaging escalates concomitant radiation doses to patients, inducing potential secondary cancer. We demonstrate the feasibility of a data-driven approach to synthesize volumetric images using patient surface images, which can be obtained from a zero-dose surface imaging system. This study includes 500 computed tomography (CT) image sets from 50 patients. Compared to the ground truth CT, the synthetic images result in the evaluation metric values of 26.9 Hounsfield units, 39.1dB, and 0.965 regarding the mean absolute error, peak signal-to-noise ratio, and structural similarity index measure. This approach provides a data integration solution that can potentially enable real-time imaging, which is free of radiation-induced risk and could be applied to image-guided medical procedures.

physics.med-ph↗

Cycle-guided Denoising Diffusion Probability Model for 3D Cross-modality MRI Synthesis

This study aims to develop a novel Cycle-guided Denoising Diffusion Probability Model (CG-DDPM) for cross-modality MRI synthesis. The CG-DDPM deploys two DDPMs that condition each other to generate synthetic images from two different MRI pulse sequences. The two DDPMs exchange random latent noise in the reverse processes, which helps to regularize both DDPMs and generate matching images in two modalities. This improves image-to-image translation ac-curacy. We evaluated the CG-DDPM quantitatively using mean absolute error (MAE), multi-scale structural similarity index measure (MSSIM), and peak sig-nal-to-noise ratio (PSNR), as well as the network synthesis consistency, on the BraTS2020 dataset. Our proposed method showed high accuracy and reliable consistency for MRI synthesis. In addition, we compared the CG-DDPM with several other state-of-the-art networks and demonstrated statistically significant improvements in the image quality of synthetic MRIs. The proposed method enhances the capability of current multimodal MRI synthesis approaches, which could contribute to more accurate diagnosis and better treatment planning for patients by synthesizing additional MRI modalities.

eess.IV↗

CBCT-Based Synthetic CT Image Generation Using Conditional Denoising Diffusion Probabilistic Model

Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART) replanning. However, the presence of severe artifacts and inaccurate Hounsfield unit (HU) values prevent its use for quantitative applications such as organ segmentation and dose calculation. To enable the clinical practice of online ART, it is crucial to obtain CBCT scans with a quality comparable to that of a CT scan. Purpose: This work aims to develop a conditional diffusion model to perform image translation from the CBCT to the CT domain for the image quality improvement of CBCT. Methods: The proposed method is a conditional denoising diffusion probabilistic model (DDPM) that utilizes a time-embedded U-net architecture with residual and attention blocks to gradually transform standard Gaussian noise to the target CT distribution conditioned on the CBCT. The model was trained on deformed planning CT (dpCT) and CBCT image pairs, and its feasibility was verified in brain patient study and head-and-neck (H&N) patient study. The performance of the proposed algorithm was evaluated using mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and normalized cross-correlation (NCC) metrics on generated synthetic CT (sCT) samples. The proposed method was also compared to four other diffusion model-based sCT generation methods. Conclusions: The proposed conditional DDPM method can generate sCT from CBCT with accurate HU numbers and reduced artifacts, enabling accurate CBCT-based organ segmentation and dose calculation for online ART.

physics.med-ph↗

Characterization of 250 MeV protons from Varian ProBeam pencil beam scanning system for FLASH radiation therapy

Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it is not typical to use 250 MeV protons for routine clinical treatments and as such 250 MeV may not have been characterized in the commissioning. In this study, we aim to characterize 250 MeV protons from Varian ProBeam system for FLASH RT as well as assess the ability of clinical monitoring ionization chamber (MIC) for FLASH-readiness. We measured data needed for beam commissioning: integral depth dose (IDD) curve, spot sigma, and absolute dose calibration. To evaluate MIC, we measured output as a function of beam current. To characterize a 250 MeV FLASH beam, we measured: (1) central axis DR as a function of current and spot spacing and arrangement, (2) for a fixed spot spacing, the maximum field size that still achieves FLASH DR (i.e., > 40 Gy/s), (3) DR reproducibility. All FLASH DR measurements were performed using ion chamber for the absolute dose and irradiation times were obtained from log files. We verified dose measurements using EBT-XD films and irradiation times using a fast, pixelated spectral detector. R90 and R80 from IDD were 37.58 and 37.69 cm, and spot sigma at isocenter were σx=3.336 and σy=3.332 mm, respectively. The absolute dose output was measured as 0.377 GyE*mm2/MU for the commissioning conditions. Output was stable for beam currents up to 15 nA, and it gradually increased to 12-fold for 115 nA. DR depended on beam current, spot spacing and arrangement and could be reproduced within 4.2% variations. Even though FLASH was achieved and the largest field size that delivers FLASH DR was determined as 35x35 mm2, current MIC has DR dependence and users should measure DR each time for their FLASH applications.

physics.med-ph↗