Searcharxiv⌕ Search

arXiv subjects

Chloé Najac

Publications and source records attributed to Chloé Najac.

7 recordsLinked to original sources

Deep Unrolled Networks in Representation Space Applied to MRI Reconstruction

Deep unrolled networks (DUNs) integrate physical forward models with learned regularization in cascaded network architectures, achieving exceptional performance in inverse problems while maintaining interpretability. While most DUNs operate in the object domain (e.g., image space), recent variants explored representation spaces for improved information flow. However, these methods rely on heuristic methods for data consistency (DC), sacrificing fidelity with measurements. In this work, we introduce DUNE (Deep Unrolled Networks in rEpresentation space), a framework that maintains exact adherence to physical measurements while operating in learned representation spaces. By deriving the DC gradient via the chain rule and implementing it through the Vector-Jacobian Product (VJP), we enable exact backpropagation of measurement residuals into the representation space. This formulation supports diverse architectural backbones, including pre-trained encoders to guide the iterative process. We assess DUNE against state-of-the-art baselines on accelerated MRI reconstruction tasks, demonstrating that exact VJP-based gradients yield superior reconstruction quality and structural fidelity across both single-channel portable low-field and multi-channel clinical high-field MRI acquisitions. The code will be available upon publication at https://github.com/EfeIlicak/DUNE.

eess.IV↗

Synthetic Data in MR Spectroscopy: Current Practices, Applications, and Considerations

The use of synthetic data has emerged as an essential tool in Magnetic Resonance Spectroscopy (MRS) research and applications, providing advantages for optimization of acquisition, software validation, deep learning applications, and enhanced reproducibility. Importantly, synthetic data addresses challenges of limited training data availability, particularly for clinical populations, and offers controlled solutions for investigating uncertainties and unexplained variance with in vivo data. This work provides a review and evaluation of current practices in the use and generation of synthetic data within the MRS field. Conducted by the MRS Synthetic Data Working Group under the Code & Data Sharing Committee of the MRS Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM), this manuscript encompasses existing literature, supplemented by collective experience and in-house methodologies.

physics.med-ph↗

Physics-Guided Dual-Domain Network with Attention-Based Fusion for Portable MRI Reconstruction

Portable low-field magnetic resonance imaging (MRI) systems have gained renewed interest owing to their cost effectiveness and point-of-care imaging capabilities. Yet, portable MRI systems suffer from relatively low signal-to-noise ratio and limited hardware capabilities. While previous works have proposed the use of deep learning based reconstruction methods to improve low-field image quality, these operated only in the image-domain. Unlike other imaging modalities, MRI directly acquires data in the Fourier-domain (k-space), and exploiting both k-space and image-domain information can improve reconstruction quality. Here, we introduce DUN-DD, a novel physics-guided 3D network for portable MRI reconstruction, with parallel dual-domain branches whose outputs are combined together via an attention-based fusion network. To demonstrate the performance of the proposed method, we present \textit{in vivo} reconstructions obtained from both emulated datasets as well as images acquired with a 47mT Halbach-based portable MRI system. Our results show that DUN-DD outperforms state-of-the-art classical, data-driven, and physics-guided methods on both emulated and real portable MRI acquisitions.

physics.med-ph↗

Physics-Informed Deep Unrolled Network for Portable MR Image Reconstruction

Magnetic resonance imaging (MRI) is the gold standard imaging modality for numerous diagnostic tasks, yet its usefulness is tempered due to its high cost and infrastructural requirements. Low-cost very-low-field portable scanners offer new opportunities, while enabling imaging outside conventional MRI suites. However, achieving diagnostic-quality images in clinically acceptable scan times remains challenging with these systems. Therefore methods for improving the image quality while reducing the scan duration are highly desirable. Here, we investigate a physics-informed 3D deep unrolled network for the reconstruction of portable MR acquisitions. Our approach includes a novel network architecture that utilizes momentum-based acceleration and leverages complex conjugate symmetry of k-space for improved reconstruction performance. Comprehensive evaluations on emulated datasets as well as 47mT portable MRI acquisitions demonstrate the improved reconstruction quality of the proposed method compared to existing methods.

physics.med-ph↗

Subject grounding to reduce electromagnetic interference for MRI scanners operating in unshielded environments

Purpose. Portable low-field (< 0.1 T) MRI is increasingly used for point-of-care imaging, but electromagnetic interference (EMI) presents a significant challenge, especially in unshielded environments. EMI can degrade image quality and compromise diagnostic utility. This study investigates whether subject grounding can effectively reduce EMI and improve image quality, comparing different grounding strategies. Methods. Experiments were conducted using a 47 mT Halbach-based MRI scanner with a single receive channel. Reproducibility was evaluated at a second site using a 72 mT scanner with similar geometry. Turbo spin echo sequences were used to image the hand and brain. Subject grounding was implemented using conductive cloth sleeves or ECG electrodes, each connected between the subject's skin and scanner ground. Three EMI conditions were tested: ambient, added single-frequency EMI, and broadband EMI. Signal-to-noise ratios (SNR) were calculated under each configuration. Results. Subject grounding significantly reduced EMI in both hand and brain scans. In hand imaging, conductive sleeves reduced noise from 85x to 1.25x the 50-ohm noise floor. In brain imaging, grounding alone reduced noise from 55x to 25x baseline; when combined with arc RF shields, noise was further reduced to 1.2x baseline, even under added EMI. These results were reproducible across different scanners and locations. Conclusion. Subject grounding is a simple, effective, and reproducible strategy for mitigating EMI in portable low-field MRI. It is especially effective for hand imaging, while brain imaging benefits from additional RF shielding. The approach is robust under various EMI conditions and may complement other denoising techniques.

physics.med-ph↗

Diffusion-weighted MR spectroscopy: consensus, recommendations and resources from acquisition to modelling

Brain cell structure and function reflect neurodevelopment, plasticity and ageing, and changes can help flag pathological processes such as neurodegeneration and neuroinflammation. Accurate and quantitative methods to non-invasively disentangle cellular structural features are needed and are a substantial focus of brain research. Diffusion-weighted MR spectroscopy (dMRS) gives access to diffusion properties of endogenous intracellular brain metabolites that are preferentially located inside specific brain cell populations. Despite its great potential, dMRS remains a challenging technique on all levels: from the data acquisition to the analysis, quantification, modelling and interpretation of results. These challenges were the motivation behind the organisation of the Lorentz Workshop on 'Best Practices and Tools for Diffusion MR Spectroscopy' held in Leiden in September 2021. During the workshop, the dMRS community established a set of recommendations to execute robust dMRS studies. This paper provides a description of the steps needed for acquiring, processing, fitting and modelling dMRS data and provides links to useful resources.

physics.med-ph↗

Compartmental diffusion and microstructural properties of human brain gray and white matter studied with double diffusion encoding magnetic resonance spectroscopy of metabolites and water

Double diffusion encoding (DDE) magnetic resonance measurements of the water signal offers a unique ability to separate the effect of microscopic anisotropic diffusion in structural units of tissue from the overall macroscopic orientational distribution of cells. However, the specificity in detected microscopic anisotropy is limited as the signal is averaged over different cell types and across tissue compartments. Performing side-by-side metabolite DDE spectroscopy (DDES) and water DDES in which a wide range of b-values is used to gradually eliminate the extracellular contribution provides complementary measures from which intracellular and extracellular microscopic fractional anisotropies ($μ$FA) and diffusivities can be estimated. Metabolites are largely confined to the intracellular space and therefore provide a benchmark for intracellular diffusivity of specific cell types. Here, we aimed to estimate tissue- and compartment-specific human brain microstructure by combining water and metabolites DDES experiments. We performed DDES in human subjects in two brain regions that contain widely different amounts of white matter (WM) and gray matter (GM): parietal white matter (PWM) and occipital gray matter (OGM) on a 7 T MRI scanner. Results of the metabolite DDES experiments in both PWM and OGM suggest a highly anisotropic intracellular space within neurons and glia, with the possible exception of gray matter glia. Tortuosity values in the cytoplasm for water and tNAA, obtained with correlation analysis of microscopic parallel diffusivity with respect to GM/WM tissue fraction in the volume of interest, are remarkably similar for both molecules, while exhibiting a clear difference between gray and white matter, suggesting a more crowded cytoplasm and more complex cytomorphology of neuronal cell bodies and dendrites in GM than those found in long-range axons in WM.

physics.med-ph↗