SearcharxivSearch

arXiv subjects

Chris Armstrong

Publications and source records attributed to Chris Armstrong.

4 recordsLinked to original sources

Quantitative phase nano-imaging with a laboratory source

Investigating the structure of matter at the nanoscale non destructively is a key capability enabled by X-ray imaging. One of the most powerful nano-imaging methods is X-ray ptychography, a coherent diffraction imaging technique that has become the go-to method at synchrotron facilities for applications ranging from brain imaging to battery materials. However, the requirements in terms of X-ray beam quality have limited its use to large synchrotron facilities and, to date, only one attempt has been made to translate the technique to a small-scale laboratory. To unleash the power of this technique to the broad user community of laboratory X-ray sources, there are outstanding questions to answer including whether the quantitativeness of the information is preserved in a laboratory despite the drastic decrease in X-ray flux of several orders of magnitude, with respect to synchrotron instruments. In this study not only we demonstrate that the quantitativeness of X-ray ptychography is preserved in a laboratory setting, but we also apply the method to the imaging of a brain tissue phantom. Finally, we describe the current challenges and limitations, and we set the basis for further development and future directions of quantitative nano-imaging with laboratory X-ray sources.

physics.comp-ph

Interface for Sparse Linear Algebra Operations

The standardization of an interface for dense linear algebra operations in the BLAS standard has enabled interoperability between different linear algebra libraries, thereby boosting the success of scientific computing, in particular in scientific HPC. Despite numerous efforts in the past, the community has not yet agreed on a standardization for sparse linear algebra operations due to numerous reasons. One is the fact that sparse linear algebra objects allow for many different storage formats, and different hardware may favor different storage formats. This makes the definition of a FORTRAN-style all-circumventing interface extremely challenging. Another reason is that opposed to dense linear algebra functionality, in sparse linear algebra, the size of the sparse data structure for the operation result is not always known prior to the information. Furthermore, as opposed to the standardization effort for dense linear algebra, we are late in the technology readiness cycle, and many production-ready software libraries using sparse linear algebra routines have implemented and committed to their own sparse BLAS interface. At the same time, there exists a demand for standardization that would improve interoperability, and sustainability, and allow for easier integration of building blocks. In an inclusive, cross-institutional effort involving numerous academic institutions, US National Labs, and industry, we spent two years designing a hardware-portable interface for basic sparse linear algebra functionality that serves the user needs and is compatible with the different interfaces currently used by different vendors. In this paper, we present a C++ API for sparse linear algebra functionality, discuss the design choices, and detail how software developers preserve a lot of freedom in terms of how to implement functionality behind this API.

cs.MS

Electron volt energy resolution with ptychography using a broadband continuum spectrum

Ptychography is a scanning coherent diffraction imaging technique successfully applied in the electron, visible and x-ray regimes. One of the distinct features of ptychography with respect to other coherent diffraction techniques is its capability of dealing with partial spatial and temporal coherence via the reconstruction algorithm. Here we focus on the temporal and clarify theoretically and with simulations the constraints which affect the energy resolution limits of the ptychographic algorithms. Based on this, we design and perform simulations for a broadband ptychography in the hard x-ray regime, which enables an energy resolution down to 1 eV. We benchmark the simulations against experimental ptychographic data from a nickel test sample, by extracting the x-ray absorption near edge spectrum with energy resolution of 5 eV using a continuum spectrum of 20 eV bandwidth. We review the results, discuss the limitations, and provide guidelines for future broadband ptychography experiments, its prospective applications and potential impact on achieving diffraction limited resolutions.

physics.app-ph

THz pulses over 50 millijoules generated from relativistic picosecond laser-plasma interactions

Ultrahigh-power terahertz (THz) radiation sources are essential for many applications, such as nonlinear THz physics, THz-wave based compact accelerators, etc. However, until now none of THz sources reported, whether based upon large-scale accelerators or high power lasers, have produced THz pulses with energies above the millijoule (mJ) barrier. Here we report on the efficient generation of low-frequency (<3 THz) THz pulses with unprecedentedly high energies over 50 mJ. The THz radiation is produced by coherent transition radiation of a picosecond laser-accelerated ultra-bright bunch of relativistic electrons from a solid target. Such high energy THz pulses can not only trigger various nonlinear dynamics in matter, but also open up a new research field of relativistic THz optics.

physics.plasm-ph