SearcharxivSearch

arXiv subjects

Christian Geindreau

Publications and source records attributed to Christian Geindreau.

3 recordsLinked to original sources

Revealing 3D orientation and strain heterogeneity in calcite generated by bio-cementation

Bio-cementation uses bacterially induced calcite to bind sand grains, offering a low-carbon approach to soil stabilization. However, the 3D morphology, orientation texture, and internal strain states of individual calcite bonds remain insufficiently characterized. Here, we combine computed micro-tomography, 3D X-ray Diffraction (3DXRD), and Dark-Field X-ray Microscopy (DFXM) to nondestructively characterize grain morphology, crystallographic orientation, and both type II (intergranular) and type III (intragranular) elastic strains in calcite formed at sand-sand contacts during bio-cementation. Tomography establishes the sample morphology and the cemented contact architecture; 3DXRD provides grain-averaged orientation and strain states; and DFXM resolves sub-grain misorientations and localized strain concentrations generated during growth with 100 nm resolution. The combined results show that calcite precipitation through bio-cementation produces anisotropic internal strain and distinct sub-domain structures that can influence bond integrity and load transfer at the macroscopic scale.

cond-mat.mtrl-sci

Patient-specific simulation of stent-graft deployment within an abdominal aortic aneurysm

In this study, finite element analysis is used to simulate the surgical deployment procedure of a bifurcated stent-graft on a real patient's arterial geometry. The stent-graft is modeled using realistic constitutive properties for both the stent and most importantly for the graft. The arterial geometry is obtained from pre-operative imaging exam. The obtained results are in good agreement with the post-operative imaging data. As the whole computational time was reduced to less than 2 hours, this study constitutes an essential step towards predictive planning simulations of aneurysmal endovascular surgery

physics.med-ph

Computational comparison of the bending behavior of aortic stent-grafts

Secondary interventions after endovascular repair of abdominal aortic aneurysms are frequent because stent-graft (SG) related complications may occur (mainly endoleak and SG thrombosis). Complications have been related to insufficient SG flexibility, especially when devices are deployed in tortuous arteries. Little is known on the relationship between SG design and flexibility. Therefore, the aim of this study was to simulate numerically the bending of two manufactured SGs (Aorfix-Lombard Medical (A) and Zenith-Cook Medical Europe (Z)) using finite element analysis (FEA). Global SG behavior was studied by assessing stent spacing variation and cross-section deformation. Four criteria were defined to compare flexibility of SGs: maximal luminal reduction rate, torque required for bending, maximal membrane strains in graft and maximal Von Mises stress in stents. For angulation greater than 60\degree, values of these four criteria were lower with A-SG, compared to Z-SG. In conclusion, A-SG was more flexible than Z-SG according to FEA. A-SG may decrease the incidence of complications in the setting of tortuous aorto-iliac aneurysms. Our numerical model could be used to assess flexibility of further manufactured as well as newly designed SGs.

physics.med-ph