SearcharxivSearch

arXiv subjects

Christina Boemer

Publications and source records attributed to Christina Boemer.

5 recordsLinked to original sources

Polariton spectroscopy at the diamond K-edge via X-ray parametric down-conversion

It has recently been shown that x-ray parametric down-conversion (XPDC) provides access to high-energy polaritons, resulting from the hybridization of down-converted photons with electronic excitations in a nonlinear medium. Here, we present a spectrally resolved study of this effect around the K-shell absorption edge in diamond. Our results exhibit pronounced signatures of polaritonic hybridization, which we visualize by introducing a polariton spectral map and analyze by help of theoretical modelling. We find that the hybridization at this absorption edge results in substantially higher coupling strength than previously reported for a non-resonant case and reaches well into the strong-coupling regime. In addition, we demonstrate how our measurements of polaritonic XPDC allow us to extract the refractive index for bulk diamond at high spectral resolution around the carbon K-edge.

physics.ins-det

Probing the Linewidth of the 12.4-keV Solid-State $^{45}$Sc Isomeric Resonance

The $^{45}$Sc nuclear transition from the ground to the isomeric state at 12.389~keV, with a lifetime of 0.46~s, exhibits an extraordinarily narrow natural width of 1.4~feV and a quality factor $\simeq 10^{19}$ -- surpassing those of the most precise atomic clocks -- making $^{45}$Sc a compelling platform for advanced metrology and nuclear clocks. Here we investigate how closely the spectral width and quality factor of the solid-state $^{45}$Sc resonance can approach these natural limits. Using the European X-ray Free-Electron Laser, we confirm the isomer's lifetime via time-delayed incoherent $K_{α,β}$ fluorescence and observe previously unreported elastic fluorescence, yielding a partial internal conversion coefficient of 390(60). The absence of a clear nuclear forward scattering signal beyond a 2-ms delay implies environmental broadening of at least $500~Γ_{0}$ under experimental conditions, placing bounds on solid-state decoherence mechanisms. These findings set new experimental benchmarks for solid-state nuclear clock development.

quant-ph

Towards novel probes for valence charges via X-ray optical wave mixing

We present a combined theoretical and experimental study of X-ray optical wave mixing. This class of nonlinear phenomena combines the strengths of spectroscopic techniques from the optical domain, with the high-resolution capabilities of X-rays. In particular, the spectroscopic sensitivity of these phenomena can be exploited to selectively probe valence dynamics. Specifically, we focus on the effect of X-ray parametric down-conversion. We present a theoretical description of the process, from which we deduce the observable nonlinear response of valence charges. Subsequently, we simulate scattering patterns for realistic conditions and identify characteristic signatures of the nonlinear conversion. For the observation of this signature, we present a dedicated experimental setup and results of a detailed investigation. However, we do not find evidence of the nonlinear effect. This finding stands in strong contradiction to previous claims of proof-of-principle demonstrations. Nevertheless, we are optimistic to employ related X-ray optical wave mixing processes on the basis of the methods presented here for probing valence dynamics in the future.

physics.optics

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers

We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 $μ$J. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

physics.optics

X-ray parametric down-conversion: Challenging previous findings on the basis of improved experimental methods

X-ray parametric down-conversion is a fundamental nonlinear effect that promises a wide range of possible applications. Nevertheless, it has been scarcely investigated and unequivocal evidence of the effect is still missing for certain spectral regions. In particular, this is the case for down-conversion into pairs of x-ray and optical photons, which would open pathways to characterise and image valence electron-density fluctuations. In this work, we present a systematic approach to scan the parameter space, wherein we expect to identify the effect based on its characteristic signature. Within the resolution of the experimental setup we cannot establish any evidence for the nonlinear effect. Instead, we trace the measured signals back to elastic scattering contributions, thereby challenging the interpretation of previous studies on the effect of x-ray parametric down conversion producing photons in the visible spectral range. As a benchmark for future investigations of x-ray parametric down-conversion - both experimental and theoretical - we extract an upper bound for the effect's conversion efficiency of $10^{-11}$ within the resolution of our setup.

physics.optics