SearcharxivSearch

arXiv subjects

Christina Graf

Publications and source records attributed to Christina Graf.

3 recordsLinked to original sources

Dichography: Two-frame Ultrafast Imaging from a Single Diffraction Pattern

We experimentally demonstrate that pairs of time-delayed ultrabright and ultrashort X-ray pulses of two different colors, delivered by modern X-ray Free Electron Lasers, can provide two time-delayed snapshots of a sample. We introduce Dichography, a method that algorithmically separates the diffraction signals overlapping on the detector and independently retrieves the two images of the specimen. We employ Dichography to reconstruct two views of individual xenon-doped helium nanodroplets with 20 nm spatial resolution. The consistency of structures observed in both images at delays up to 750 fs provides evidence that, under these illumination conditions, significant structural damage only occurs at longer timescales. We further validate the method by imaging pairs of silver nanoparticles intercepted by the same light pulse. Dichography enables a new class of experiments across physics, chemistry, and materials science, making a significant step toward the original promise of X-ray free-electron lasers to capture ultrafast movies of nanomatter.

physics.optics

Enhanced and Robust Contrast in CEST MRI: Saturation Pulse Shape Design via Optimal Control

Purpose: To employ optimal control for the numerical design of CEST saturation pulses to maximize contrast and stability against $B_0$ inhomogeneities. Theory and Methods: We applied an optimal control framework for the design pulse shapes for CEST saturation pulse trains. The cost functional minimized both the pulse energy and the discrepancy between the corresponding CEST spectrum and the target spectrum based on a continuous RF pulse. The optimization is subject to hardware limitations. In measurements on a 7 T preclinical scanner, the optimal control pulses were compared to continuous-wave and Gaussian saturation methods. We conducted a comparison of the optimal control pulses were compared to with Gaussian, block pulse trains, and adiabatic spin-lock pulses. Results: The optimal control pulse train demonstrated saturation levels comparable to continuous-wave saturation and surpassed Gaussian saturation by up to 50 \% in phantom measurements. In phantom measurements at 3 T the optimized pulses not only showcased the highest CEST contrast, but also the highest stability against field inhomogeneities. In contrast, block pulse saturation resulted in severe artifacts. Dynamic Bloch-McConnell simulations were employed to identify the source of these artifacts, and underscore the $B_0$ robustness of the optimized pulses. Conclusion: In this work, it was shown that a substantial improvement in pulsed saturation CEST imaging can be achieved by using Optimal Control design principles. It is possible to overcome the sensitivity of saturation to B0 inhomogeneities while achieving CEST contrast close to continuous wave saturation.

physics.med-ph

Rational Approximation of Golden Angles: Accelerated Reconstructions for Radial MRI

Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational increments prohibit precomputation of the point-spread function (PSF), can lead to numerical problems, and require more complex processing steps. To avoid these problems, a new sampling scheme based on a rational approximation of golden angles (RAGA) is developed. Methods: The theoretical properties of RAGA sampling are mathematically derived. Sidelobe-to-peak ratios (SPR) are numerically computed and compared to the corresponding golden ratio sampling schemes. The sampling scheme is implemented in the BART toolbox and in a radial gradient-echo sequence. Feasibility is shown for quantitative imaging in a phantom and a cardiac scan of a healthy volunteer. Results: RAGA sampling can accurately approximate golden ratio sampling and has almost identical PSF and SPR. In contrast to golden ratio sampling, each frame can be reconstructed with the same equidistant trajectory using different sampling masks, and the angle of each acquired spoke can be encoded as a small index, which simplifies processing of the acquired data. Conclusion: RAGA sampling provides the advantages of golden ratio sampling while simplifying data processing, rendering it a valuable tool for dynamic and quantitative MRI.

physics.med-ph