SearcharxivSearch

arXiv subjects

Christoph Forman

Publications and source records attributed to Christoph Forman.

2 recordsLinked to original sources

Robust Centerline Prediction for Accurate Vessel Wall Visualization of Intracranial Vessels in Multi-Contrast 3D MRI Data

An accurate planar visualization (curved planar reformation - CPR) of intracranial arteries is mandatory for an improved luminal and mural assessment especially in low resolution Magnetic Resonance Imaging (MRI) data sets acquired in standard clinical settings. CPR visualization methods based on the centerline of the desired structure are fast and easy to implement but the accuracy strongly depends on the spatial resolution of the 3D data set and the size of the desired vessel. In the manuscript, a novel algorithm for fast and robust centerline calculation in multi-contrast 3D MRI data is presented. It considers the extracted surface of the vessel structure for a more accurate centerline prediction resulting in an enhanced CPR visualization of small vessels.

physics.med-ph

Automated Cardiac Resting Phase Detection Targeted on the Right Coronary Artery

Static cardiac imaging such as late gadolinium enhancement, mapping, or 3-D coronary angiography require prior information, e.g., the phase during a cardiac cycle with least motion, called resting phase (RP). The purpose of this work is to propose a fully automated framework that allows the detection of the right coronary artery (RCA) RP within CINE series. The proposed prototype system consists of three main steps. First, the localization of the regions of interest (ROI) is performed. Second, the cropped ROI series are taken for tracking motions over all time points. Third, the output motion values are used to classify RPs. In this work, we focused on the detection of the area with the outer edge of the cross-section of the RCA as our target. The proposed framework was evaluated on 102 clinically acquired dataset at 1.5T and 3T. The automatically classified RPs were compared with the reference RPs annotated manually by a expert for testing the robustness and feasibility of the framework. The predicted RCA RPs showed high agreement with the experts annotated RPs with 92.7% accuracy, 90.5% sensitivity and 95.0% specificity for the unseen study dataset. The mean absolute difference of the start and end RP was 13.6 $\pm$ 18.6 ms for the validation study dataset (n=102). In this work, automated RP detection has been introduced by the proposed framework and demonstrated feasibility, robustness, and applicability for static imaging acquisitions.

eess.IV