SearcharxivSearch

arXiv subjects

Christoph Gaßner

Publications and source records attributed to Christoph Gaßner.

2 recordsLinked to original sources

Extending the field of view in modulation-based X-ray phase microtomography

Recent advances in propagation-based phase-contrast imaging, such as hierarchical imaging, have enabled the visualization of internal structures in large biological specimens and material samples. However, modulation-based techniques, which provide quantitative electron density information, face challenges when imaging larger objects due to stringent beam stability requirements and detector distortions. Extending the field of view of these methods is crucial for obtaining comparable quantitative results across beamlines and adapting to the smaller beam profiles of fourth-generation synchrotron sources. We introduce a novel image processing technique combining an eigenflat optimization with deformable image registration to address the challenges and enable quantitative high-resolution scans of centimeter-sized objects with multiple-micrometer resolution. We demonstrate the potential of the method by obtaining an electron density map of a rat brain sample 15 mm in diameter despite the limited horizontal field of view of 6 mm of the beamline. This showcases the technique's ability to significantly widen the range of applications of modulation-based techniques in both biological and materials science research.

physics.med-ph

Towards low-cost lead screening with transmission XRF

Human exposure to lead (Pb) is a global health concern, yet existing technologies for detecting lead in our environment remain prohibitively expensive for widespread deployment. Here we present a new concept towards lead screening using X-ray fluorescence (XRF) in an unconventional geometry we coin transmission XRF in which the sample is placed between the source and detector. For cost reduction, we then show that $^{241}$Am found in ionizing smoke detectors is spectrally suitable for Pb L-shell XRF generation and can thus replace X-ray tubes used in conventional XRF devices. Exploring soil screening as the first application, we demonstrate with Monte Carlo simulations that a configuration with 7$\times$ $^{241}$Am sources and a standard silicon drift detector can enable screening-relevant detection limits (100 ppm Pb) in soil within practical measurement times (<30 min). We believe this concept opens a route toward low-cost and scalable XRF instrumentation for democratizing lead screening across a wide range of samples.

physics.ins-det