Retrieval of multiple fibre orientations using X-ray dark-field signal modelling

Dark-field imaging is widely used to infer fibre orientation from signal modulation as a function of sample orientation. However, current X-ray dark-field retrieval methods are restricted to single orientations and require tomography to resolve overlapping structures. This approach is time-consuming and not suitable for thin materials, which are common in materials science. Here we present a dark-field model capable of retrieving multiple fibre orientations within a single pixel. The model, based on a geometrical description of fibre scattering, was validated through Monte Carlo simulations and experiments using beam-tracking setups with 1D and 2D masks. Results demonstrate reliable orientation retrieval for up to two fibres per pixel, with the 2D mask providing multi-directional sensitivity in a single acquisition and enabling faster and simplified data collection.

physics.med-ph

Quantitative 3D imaging of highly distorted micro-crystals using Bragg ptychography

Bragg coherent diffraction imaging (BCDI) fails to reliably retrieve phases in micro-crystals exhibiting strong strain inhomogeneities, which restricts its applicability. Here we show that three-dimensional Bragg ptychography (3DBP) overcomes this limitation by enabling stable inversion for large lattice distortions. Using a combination of experimental measurements and numerical tests, we compare the performance limits of the two approaches and demonstrate that 3DBP tolerates lattice distortions more than six times larger than BCDI. We also establish the sensitivity of both methods on a weakly distorted crystal, for which 3DBP yields smoother amplitude and phase fields with reduced short-length-scale artifacts. 3DBP thus provides a reliable route for imaging micro-crystals with large lattice distortions, expanding the scope of coherent X-ray Bragg microscopy to strongly deformed systems.

physics.optics

Revealing Nanoscale Ni-Oxidation State Variations in Single-Crystal NMC811 via 2D and 3D Spectro-Ptychography

Enabling lithium (Li)-ion batteries with higher energy densities, longer cycle life, and lower costs will underpin the widespread electrification of the transportation and large-scale energy storage industries. Nickel (Ni)-rich layered oxide cathodes, such as LiNi$_{x}$Mn$_{y}$Co$_{z}$O$_{2}$ (NMC, x > 0.8), have gained popularity due to their high specific capacities and lower cobalt content. However, the standard polycrystalline morphology suffers from accelerated degradation at voltages above 4.2 V versus graphite, due to its increased mechanical and chemical instability. Single-crystal NMC (SC-NMC) has emerged as a promising morphology for suppressing the mechanical instability by preventing intergranular cracking; however, robust methods of understanding its chemical degradation pathways are required. We demonstrate how a high-throughput data collection strategy unlocks the ability to perform 2D and 3D ptychography in minutes, where it currently requires hours, and combine this with X-ray absorption near edge spectroscopy (XANES) to visualise the local Ni oxidation state behaviour in SC-NMC811, with nanometre-scale spatial resolution, and use this as a proxy for state-of-charge. By employing this technique at various stages during lifetime cycling to high voltages (>4.2 V), direct mapping of chemical degradation along the Li channels, identification of nucleation sites, and observation of Ni oxidation state heterogeneities across both electrode and particle scales can be achieved. We further correlate these heterogeneities with the formation and growth of the rocksalt phase and oxygen-induced planar gliding. This methodology will advance the fundamental understanding of how high-Ni layered oxide materials chemically degrade during high-voltage operation, guiding the design of more durable battery materials.

cond-mat.mtrl-sci

X-ray Ptychography with a Laboratory Source

X-ray ptychography has revolutionised nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. We conducted an experiment with a liquid metal-jet X-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 microns to produce a ptychographic phase image of a Siemens star test pattern with a sub-micron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide.

physics.app-ph

Optimizing contrast and spatial resolution in hard X-ray tomography of medically relevant tissues

Hard X-ray tomography with Paganin's widespread single-distance phase retrieval filter improves contrast-to-noise ratio (CNR) while reducing spatial resolution (SR). We demonstrate that a Gaussian filter provided larger CNR at high SR with interpretable density measurements for two medically relevant soft tissue samples. Paganin's filter produced larger CNR at low SR, though \emph{a priori} assumptions were generally false and image quality gains diminish for CNR $>1$. Therefore, simple absorption measurements of low-$Z$ specimens combined with Gaussian filtering can provide improved image quality and model-independent density measurements compared to single-distance phase retrieval.

physics.med-ph

High-Resolution Hard X-ray Holography by Unconfined Atomic Layer Deposited Phase-Shifting 3D References

We demonstrate high-resolution non-iterative holographic coherent diffraction imaging with hard X-rays using a novel phase-shifting reference, fabricated by atomic layer deposition to produce nanosharp 3D structure. The method surpasses the limitations associated with absorbing substrates predominantly employed in soft X-ray holography using extended, customized and point-source references. The unconfined experimental setup relaxes the technical constraints, allows effective data correction, and enables independent sample translation and rotation for data averaging and tomography. Applicable to single-shot measurements, phase and amplitude reconstructions of samples are retrieved with single-pixel resolution and differential contrast by simple non-iterative computation.

cond-mat.mes-hall