SearcharxivSearch

arXiv subjects

Christophe Masselon

Publications and source records attributed to Christophe Masselon.

4 recordsLinked to original sources

Optomechanical mass spectrometry

It has been demonstrated in the recent years that nanomechanical mass spectrometry was well suited for the analysis of specific high mass species such as viruses. Still, the exclusive use of one-dimensional devices such as vibrating beams forces a trade-off between analysis time (related to capture area) and mass resolution (inversely proportional to device mass). Such devices also require complex readout schemes to simultaneously monitor multiple resonance modes, in particular when stiffness or shape come into play, which degrades mass resolution. These issues restrict nanomechanical MS to the analysis of species with specific properties. We report here the first demonstration of single-particle mass spectrometry with nano-optomechanical resonators fabricated with a Very Large Scale Integration process. The unique motion sensitivity of optomechanical techniques allows the use of resonators with new topologies. The device introduced here is designed to be impervious to particle position, stiffness or shape, opening the way to the analysis of large aspect ratio biological objects of great significance such as viruses with a tail or fibrils. Compared to top-down beam resonators with electrical read-out and state-of-the-art mass resolution, we show a three-fold improvement in capture area with no resolution degradation, despite the use of a single resonance mode. Short analysis time is in reach thanks to the sensitivity and bandwidth of optomechanical read-out and its compliance with telecom multiplexing techniques.

physics.app-ph

Charge-independent mass spectrometry of single virus capsids above 100MDa with nanomechanical resonators

Most technologies, including conventional mass spectrometry, struggle to measure the mass of particles in the MDa to GDa range. Although this mass range appears optimal for nanomechanical resonators, early nanomechanical-MS systems suffered from prohibitive sample loss, extended analysis time or inadequate resolution. Here, we report on a novel system architecture combining nebulization of the analytes from solution, their efficient transfer and focusing without relying on electromagnetic fields, and the mass measurements of individual particles using nanomechanical resonator arrays. This system determined the mass distribution of ~30 MDa polystyrene nanoparticles with a detection efficiency 6 orders of magnitude higher than previous nanomechanical-MS systems with ion guides, and successfully performed the highest molecular mass measurement to date with less than 1 picomole of bacteriophage T5 105 MDa viral capsids.

physics.app-ph

Single-particle Mass Spectrometry with arrays of frequency-addressed nanomechanical resonators

One of the main challenges to overcome to perform nanomechanical Mass Spectrometry (NEMS-MS) analysis in a practical time frame stems from the size mismatch between the analyte beam and the extremely small nanomechanical detector area. We report here the demonstration of NEMS-MS with arrays of 20 individually addressed nanomechanical resonators where the number of inputs-outputs for the whole array is the same as that of a single resonator. While all resonators within an array are interconnected via two metal levels, each resonator is designed with a distinct resonance frequency which becomes its individual address. In order to perform single-particle Mass Spectrometry, the resonance frequencies of the two first modes of each NEMS within an array are monitored simultaneously. Using such an array, mass spectra of metallic aggregates in the MDa range are acquired with more than one order of magnitude improvement in analysis time due to the increase in capture cross section compared to individual resonators. A 20 NEMS array is probed in 150ms with the same mass limit of detection as a single resonator. Spectra acquired with a conventional Time- of-Flight (TOF) mass spectrometer in the same system show excellent agreement. As individual information for each resonator within the array is retained, the array becomes a particle imager, each resonator acting as a pixel. With this technique, we demonstrate how Mass Spectrometry Imaging (MSI) at the single particle level becomes possible by mapping a 4cm-particle beam in the MDa range and above.

physics.ins-det

Neutral particle Mass Spectrometry with Nanomechanical Systems

Current approaches to Mass Spectrometry (MS) require ionization of the analytes of interest. For high-mass species, the resulting charge state distribution can be complex and difficult to interpret correctly. In this article, using a setup comprising both conventional time-of-flight MS (TOF-MS) and Nano-Electro-Mechanical-Systems-based MS (NEMS-MS) in situ, we show directly that NEMS-MS analysis is insensitive to charge state: the spectrum consists of a single peak whatever the species charge state, making it significantly clearer than existing MS analysis. In subsequent tests, all charged particles are electrostatically removed from the beam, and unlike TOF-MS, NEMS-MS can still measure masses. This demonstrates the possibility to measure mass spectra for neutral particles. Thus, it is possible to envisage MS-based studies of analytes that are incompatible with current ionization techniques and the way is now open for the development of cutting edge system architectures with unique analytical capability.

physics.ins-det