Searcharxiv⌕ Search

arXiv subjects

Christophe Moser

Publications and source records attributed to Christophe Moser.

51 records · Page 3Linked to original sources

Controlling spatiotemporal nonlinearities in multimode fibers with deep neural networks

Spatiotemporal nonlinear interactions in multimode fibers are of interest for beam shaping and frequency conversion by exploiting the nonlinear propagation of different pump regimes from quasi-continuous wave to ultrashort pulses centered around visible to infrared pump wavelengths. The nonlinear effects in multi-mode fibers depend strongly on the excitation condition, however relatively little work has been reported on this subject. Here, we present the first machine learning approach to learn and control the nonlinear frequency conversion inside multimode fibers by tailoring the excitation condition via deep neural networks. Trained with experimental data, deep neural networks are adapted to learn the relation between the spatial beam profile of the pump pulse and the spectrum generation. For different user-defined target spectra, network-suggested beam shapes are applied and control over the cascaded Raman scattering and supercontinuum generation processes are achieved. Our results present a novel method to tune the spectra of a broadband source.

physics.optics↗

Transscleral Optical Phase Imaging of the Human Retina - TOPI

The in vivo observation of the human retina at the cellular level is crucial to detect lesions before irreversible visual loss occurs, to follow the time course of retinal diseases and to evaluate and monitor the early effects of treatments. Despite the phenomenal advances in optical coherence tomography (OCT) and adaptive optics systems, in vivo imaging of several retinal cells is still elusive. Here we propose a radically different method compared to OCT, called transscleral optical phase imaging (TOPI), which allows to image retinal cells with high contrast, high resolution, and within an acquisition time suitable for clinical use. TOPI relies on high-angle oblique illumination of the retina, combined with adaptive optics, to enhance the phase contrast of transparent cells. We first present in-vivo images of retinal cells, from the retinal pigment epithelium (RPE) to the nerve and vascular layers of the retina, in eleven healthy volunteers without pupil dilation. The morphology of the cells in vivo is then compared to that of images obtained with the same technique applied on ex vivo human RPE and pig retinas. Finally, we demonstrate the ability of high resolution phase microscopy to image pericytes and microglia around rat retinal capillaries. Our results show the ability of TOPI to image and quantify retinal cells up to the RPE depth within a maximum time of 9 seconds over a field of view of 4.4 x 4.4°, opening new avenue in the in vivo exploration of the deepest layer of the retina in healthy and diseased eyes.

physics.med-ph↗

Spatiotemporal self-similar fiber laser

In this Letter, we demonstrate, to the best of our knowledge, the first spatiotemporally mode-locked fiber laser with self-similar pulse evolution. The multimode fiber oscillator generates parabolic amplifier similaritons at 1030 nm with 90 mW average power, 2.3 ps duration, and 37.9 MHz repetition rate. Remarkably, we observe experimentally a near-Gaussian beam quality (M^2<1.4) at the output of the highly multimode fiber. The output pulses are compressed to 192 fs via an external grating compressor. Numerical simulations are performed to investigate the cavity dynamics which confirm experimental observations of self-similar pulse propagation. The reported results open a new direction to investigate new types of pulse besides beam shaping and nonlinear dynamics in spatiotemporal mode-locked fiber lasers.

physics.optics↗

Multimode Optical Fiber Transmission with a Deep Learning Network

Multimode fibers (MMF) are an example of a highly scattering medium which scramble the coherent light propagating within them and produce seemingly random patterns. Thus, for applications such as imaging and image projection through a MMF, careful measurements of the relationship between inputs and outputs of the fiber are required. We show, as a proof of concept, that a deep learning neural network can learn the input-output relationship in a 0.75 m long MMF. Specifically, we demonstrate that a deep convolutional neural network (CNN) can learn the non-linear relationships between the amplitude of the speckle pattern obtained at the output of the fiber and the phase or amplitude at the input of the fiber. Effectively the network performs a non-linear inversion task. We obtained image fidelity (correlation) of ~98% compared with the image obtained using the measured matrix of the system. We further show that the network can be trained for transfer learning, i.e. it can transmit images through the MMF which belongs to another class which were not used for training/testing.

physics.optics↗

Learning to see through multimode fibers

We use Deep Neural Networks (DNNs) to classify and reconstruct a large database of handwritten digits from the intensity of the speckle patterns that result after the images propagated through multimode fibers (MMF). Images transmitted through fibers with up to 1km length were recovered. The ability of the network to recognize the input degraded with fiber length but the performance could be enhanced if the neural networks were trained to first reconstruct the image and then classify it rather than classify it directly from the speckle intensity.

physics.optics↗

A new microscopy for imaging retinal cells

The evaluation and monitoring of cells health in the human retina is crucial and follow time course of retinal diseases, detect lesions before irreversible visual loss and to evaluate treatment effects. Towards this goal, a major challenge is to image and quantify retinal cells in human eyes in a non-invasive manner. Despite the phenomenal advances in Optical Coherence Tomography (OCT) and Adaptive Optics systems, in vivo imaging of many of these cells is limited by the fact that cell contrast in reflection is extremely low. Here, we report on a major advance by proposing and demonstrating a radically different method compared with OCT to visualize retinal cells with high contrast, resolution and an acquisition time suitable for clinical use. The method uses a transscleral illumination which provides a high numerical aperture in a dark field configuration. The light backscattered by the Retinal Pigment Epithelium (RPE) and the choroid provides a forward illumination for the upper layer of the retina, thus providing a transmission illumination condition. By collecting the scattered light through the pupil, the partially coherent illumination produces dark field images, which are combined to reconstruct a quasi-quantitative phase image with twice the numerical aperture given by the eye's pupil. The retrieved quasi-quantitative phase images (QPI) of cells in ex vivo human and pig's eyes are validated with those taken with a standard QPI system. We then apply the technique in vivo on human eye, without pupil dilation, we demonstrated the feasibility to image retinal cells up to the retinal pigment epithelium within a few seconds.

physics.optics↗

Quantitative phase imaging of retinal cells

The health of cells found in the inner retinal layers of the human eye is crucial to understand the onset of diseases of the retina such as macular degeneration and retinopathy. A challenge is to periodically image these cells in human eyes to detect abnormalities well before physiological and pathological changes occur. However, in vivo imaging of many of these cells is still elusive despite the phenomenal advances in Optical Coherence Tomography (OCT) and Adaptive Optics systems. It stems from the fact that cell contrast in reflection is extremely low. Here, we report a major advance towards this goal by proposing and demonstrating a method to visualize these cells with high contrast and resolution. The method uses a transcleral illumination which provides a high numerical aperture in a dark field configuration. The light backscattered by the Retinal Pigment Epithelium (RPE) and Choroid layer provides a forward illumination for the upper layer of the retina, thus providing a transmission illumination condition. By collecting the scattered light through the pupil, the partially coherent illumination produces dark field images, which are combined to reconstruct a quantitative phase image with twice the numerical aperture given by the eye's pupil. The retrieved quantitative phase images (QPI) of cells in ex vivo human and pig's eyes are validated with those taken with a standard QPI system. We then report, to our knowledge, the very first human in vivo phase images of inner retinal cells with high contrast.

physics.med-ph↗

Three-dimensional microfabrication through a multimode optical fiber

Additive manufacturing, also known as 3D printing, is an advanced manufacturing technique that allows the fabrication of arbitrary macroscopic and microscopic objects. All 3D printing systems require large optical elements or nozzles in proximity to the built structure. This prevents their use in applications in which there is no direct access to the area where the objects have to be printed. Here, we demonstrate three-dimensional microfabrication based on two-photon polymerization (TPP) with sub diffraction-limited resolution through an ultra-thin, 50 mm long printing nozzle of 560 micrometers in diameter. Using wavefront shaping, femtosecond infrared pulses are focused and scanned through a multimode optical fiber (MMF) inside a photoresist that polymerizes via two-photon absorption. We show the construction of arbitrary 3D structures of 500 nm resolution on the other side of the fiber. To our knowledge, this is the first demonstration of microfabrication through a multimode optical fiber. Our work represents a new area which we refer to as endofabrication.

physics.optics↗

Confocal microscopy through a multimode fiber using optical correlation

We report on a method to obtain confocal imaging through multimode fibers using optical correlation. First, we measure the fiber's transmission matrix in a calibration step. This allows us to create focused spots at one end of the fiber by shaping the wavefront sent into it from the opposite end. These spots are scanned over a sample, and the light coming back from the sample via the fiber is optically correlated with the input pattern. We show that this achieves spatial selectivity in the detection. The technique is demonstrated on microbeads, a dried epithelial cell, and a cover glass.

physics.optics↗

Two-photon imaging through a multimode fiber

In this work we demonstrate 3D imaging using two-photon excitation through a 20 cm long multimode optical fiber (MMF) of 350 micrometers diameter. The imaging principle is similar to single photon fluorescence through a MMF, except that a focused femtosecond pulse is delivered and scanned over the sample. In our approach, focusing and scanning through the fiber is accomplished by digital phase conjugation using mode selection by time gating with an ultra-fast reference pulse. The excited two-photon emission is collected through the same fiber. We demonstrate depth sectioning by scanning the focused pulse in a 3D volume over a sample consisting of fluorescent beads suspended in a polymer. The achieved resolution is 1 micrometer laterally and 15 micrometers axially. Scanning is performed over an 80x80 micrometers field of view. To our knowledge, this is the first demonstration of high-resolution three-dimensional imaging using two-photon fluorescence through a multimode fiber.

physics.optics↗

Digital confocal microscopy through a multimode fiber

Acquiring high-contrast optical images deep inside biological tissues is still a challenging problem. Confocal microscopy is an important tool for biomedical imaging since it improves image quality by rejecting background signals. However, it suffers from low sensitivity in deep tissues due to light scattering. Recently, multimode fibers have provided a new paradigm for minimally invasive endoscopic imaging by controlling light propagation through them. Here we introduce a combined imaging technique where confocal images are acquired through a multimode fiber. We achieve this by digitally engineering the excitation wavefront and then applying a virtual digital pinhole on the collected signal. In this way, we are able to acquire images through the fiber with significantly increased contrast. With a fiber of numerical aperture 0.22, we achieve a lateral resolution of 1.5um, and an axial resolution of 12.7um. The point-scanning rate is currently limited by our spatial light modulator (20Hz).

physics.optics↗

Delivery of focused short pulses through a multimode fiber

Light propagation through multimode fibers suffers from spatial distortions that lead to a scrambled intensity profile. In previous work, the correction of such distortions using various wavefront control methods has been demonstrated in the continuous wave case. However, in the ultra-fast pulse regime, modal dispersion temporally broadens a pulse after propagation. Here, we present a method that compensates for spatial distortions and mitigates temporal broadening due to modal dispersion by a selective phase conjugation process in which only modes of similar group velocities are excited. The selectively excited modes are forced to follow certain paths through the multimode fiber and interfere constructively at the distal tip to form a focused spot with minimal temporal broadening. We demonstrate the delivery of focused 500 fs pulses through a 30 cm long step-index multimode fiber. The achieved pulse duration corresponds to approximately 1/30th of the duration obtained if modal dispersion was not controlled. Moreover, we measured a detailed two-dimensional map of the pulse duration at the output of the fiber and confirmed that the focused spot produces a two-photon absorption effect. This work opens new possibilities for ultra-thin multiphoton imaging through multimode fibers.

physics.optics↗

Optical-resolution photoacoustic imaging through thick tissue with a thin capillary as a dual optical-in acoustic-out waveguide

We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 μm inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 μm diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about -20 dB, much lower than the -120 dB acoustic attenuation through the fat layer. The overwhelming acoustic attenuation of high-frequency acoustic waves by biological tissue can therefore be avoided by the use of a small footprint capillary acoustic waveguide for remote detection. We finally demonstrate that the capillary can be used as a dual optical-in acoustic-out waveguide, paving the way for the development of minimally invasive optical-resolution photoacoustic endoscopes free of any acoustic or optical elements at their imaging tip.

physics.optics↗

Increasing the imaging capabilities of multimode fibers by exploiting the properties of highly scattering media

We present a novel design that exploits the focusing properties of scattering media to increase the resolution and the working distance of multimode fiber based imaging devices. Placing a highly scattering medium in front of the distal tip of the multimode fiber enables the formation of smaller sized foci at increased working distances away from the fiber tip. We perform a parametric study of the effect of the working distance and the separation between the fiber and the scattering medium on the focus size. We experimentally demonstrate submicron focused spots as far away as 800μm with 532nm light.

physics.optics↗

Optical-resolution photoacoustic microscopy by use of a multimode fiber

We demonstrate Optical-Resolution Photoacoustic Microscopy (OR-PAM), where the optical field is focused and scanned using Digital Phase Conjugation (DPC) through a multimode fiber. The focus is scanned across the field of view using digital means, and the acoustic signal induced is collected by a transducer. Optical-resolution photoacoustic images of a knot made by two absorptive wires are obtained and we report on resolution smaller than 1.5μm across a 201μm by 201μm field of view. The use of a multimode optical fiber for the optical excitation part can pave the way for miniature endoscopes that can provide optical-resolution photoacoustic images at large optical depth.

physics.optics↗