SearcharxivSearch

arXiv subjects

Christopher Mandla

Publications and source records attributed to Christopher Mandla.

3 recordsLinked to original sources

Detector Systems Engineering for Extremely Large Instruments

The scientific detector systems for the ESO ELT first-light instruments, HARMONI, MICADO, and METIS, together will require 27 science detectors: seventeen 2.5 $\mu$m cutoff H4RG-15 detectors, four 4K x 4K 231-84 CCDs, five 5.3 $\mu$m cutoff H2RG detectors, and one 13.5 $\mu$m cutoff GEOSNAP detector. This challenging program of scientific detector system development covers everything from designing and producing state-of-the-art detector control and readout electronics, to developing new detector characterization techniques in the lab, to performance modeling and final system verification. We report briefly on the current design of these detector systems and developments underway to meet the challenging scientific performance goals of the ELT instruments.

astro-ph.IM

Performance advantages of buffered mode operation of HxRG near infrared detectors

The Teledyne HxRG detectors have versatile and programmable output options to allow operation of them in a variety of configurations such as slow unbuffered, slow buffered, fast buffered or unbuffered modes to optimise the detector performance for a given application. Normally at ESO, for low noise operation, the detectors are operated in slow unbuffered mode. Whilst the slow unbuffered mode offers a simple interface to the external preamplifier electronics, the detector operation in this mode can suffer from reduced pixel frequency response and higher electrical crosstalk between the readout channels. In the context of the detector systems required for the first generation instruments of the ELT (MICADO, HARMONI and METIS), an exercise was undertaken to evaluate the noise, speed and crosstalk performance of the detectors in the slow buffered mode. A test preamplifier has been designed with options to operate a H2RG detector in buffered or unbuffered and with or without using the reference output, so a direct performance comparison can be made between different modes. This paper presents the performance advantages such as increased pixel frequency response, elimination of electrical crosstalk between the readout channels and the noise performance in the buffered mode operation. These improvements allow us to achieve the same frame readout time using half the detector cryogenic electronics and detector controller electronics for the ELT instruments, which significantly reduces the associated cryomechanical complexities in the instrument.

astro-ph.IM

The MICADO first light imager for the ELT: overview, operation, simulation

MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.

astro-ph.IM